94 research outputs found

    Monitoring immunosuppression after liver transplantation : development of individualized Bayesian limited sampling monitoring

    Get PDF
    After using C0-monitoring as the tool for therapeutic drug monitoring of cyclosporine for many years, studies suggested that C2-monitoring might be better. After switching 31 liver transplant patients using cyclosporine from C0 via C2 to flexible limited sampling models (LSM), combinations of blood sampling time points 0+2h (r_=0.94); 0+1+2h (r_=0.94); 0+1+3h (r_=0.92); 0+2+3h (r_=0.92) and 0+1+2+3h (r_=0.96) showed excellent correlation with AUC0-12h with acceptable precision and bias. When evaluating the LSM0+1+2+3h model in the 18 months after introduction there was no significant change in average cyclosporine dose and creatinine clearance, compared to previous C2-monitoring. Especially LSM0+2h was optimal in terms of accuracy, ease-of-use and intrapatient variability. When optimizing tacrolimus monitoring after calculating limited sampling formulas (LSF) and LSM single and multiple-point combinations showed good correlations with AUC0-12h. The best single point calculation in terms of estimating systemic tacrolimus exposure using LSM were LSM 4h (r_=0.97) and LSM 6h (r_=0.97). During the study of the pharmacokinetic behaviour of MMF we found a wide range in MPA clearance in the population (8.08__57.47 L/h). Looking at possible sources of this variability in MPA clearance we divided our group, based on clinical selection, into two groups (with and without calcineurin inhibitors). These groups were used for further development of LSM for monitoring MPA. The combination 0-_-1-2h showed very good correlations with trapezoidal AUC0-12h for both models, with acceptable bias and precision.Printing of this thesis was financially supported by: ZorgDomein Nederland B.V., Astellas Pharma B.V., Novartis Pharma B.V., Roche Nederland B.V., Olympus Nederland B.V., MSD B.V., Dr. Falk Pharma Benelux B.V.UBL - phd migration 201

    Two Patients with Extremely Elevated Tumor Markers: Where Is the Malignancy?

    Get PDF
    Serum tumor markers are useful to evaluate a cancer's response to treatment, for early detection of cancer relapse, and, in some cases, to diagnose malignancy. In this paper, we present two patients with significantly elevated serum tumor markers without evidence of malignant disease. An 18-year-old patient suffering from autoimmune hepatitis had markedly increased alpha-fetoprotein (aFP) levels (2,002 μg/L; normal <10 ug/L). Extensive imaging showed no signs of hepatocellular carcinoma or other cancer, and treatment with Prednisone led to rapid normalization of both liver enzymes and aFP. The second patient, a 60-year-old female with painless jaundice due to biliary stone disease, had very high serum levels of CA19-9 (18,000 kU/L, normal <27 kU/L). Liver biochemistry and serum CA19-9 concentration decreased to almost normal values (45 kU/L) after biliary stenting. These cases demonstrate that serum tumor markers can be elevated in benign disease and are therefore not appropriate to diagnose cancer

    Declining detection rates for APC and biallelic MUTYH variants in polyposis patients, implications for DNA testing policy

    Get PDF
    This study aimed to determine the prevalence of APC-associated familial adenomatous polyposis (FAP) and MUTYH-associated polyposis (MAP) in a large cohort, taking into account factors as adenoma count and year of diagnosis. All application forms used to send patients in for APC and MUTYH variant analysis between 1992 and 2017 were collected (n = 2082). Using the data provided on the application form, the APC and biallelic MUTYH prevalence was determined and possible predictive factors were examined using multivariate multinomial logistic regression analysis in SPSS. The prevalence of disease causing variants in the APC gene significantly increases with adenoma count while MAP shows a peak prevalence in individuals with 50–99 adenomas. Logistic regression analysis shows significant odds ratios for adenoma count, age at diagnosis, and, interestingly, a decline in the chance of finding a variant in either gene over time. Moreover, in 22% (43/200) of patients with FAP-related extracolonic manifestations a variant was identified. The overall detection rates are above 10% for patients with >10 adenomas aged 20 adenomas aged T variant in the tumor or a first-degree relative with >10 adenomas. Therefore, APC and MUTYH testing in patients with >10 adenomas aged 20 adenomas aged <70 is advised. Almost all FAP and MAP patients not meeting these criteria showed other characteristics that can be used as an indication to prompt genetic testing

    Predicting procedure duration of colorectal endoscopic submucosal dissection at Western endoscopy centers

    Get PDF
    Background and study aims Overcoming logistical obstacles for the implementation of colorectal endoscopic submucosal dissection (ESD) requires accurate prediction of procedure times. We aimed to evaluate existing and new prediction models for ESD duration.Patients and methods Records of all consecutive patients who underwent single, non-hybrid colorectal ESDs before 2020 at three Dutch centers were reviewed. The performance of an Eastern prediction model [GIE 2021;94(1):133–144] was assessed in the Dutch cohort. A prediction model for procedure duration was built using multivariable linear regression. The model’s performance was validated using internal validation by bootstrap resampling, internal-external cross-validation and external validation in an independent Swedish ESD cohort.Results A total of 435 colorectal ESDs were analyzed (92% en bloc resections, mean duration 139 minutes, mean tumor size 39 mm). The performance of current unstandardized time scheduling practice was suboptimal (explained variance: R2=27%). We successfully validated the Eastern prediction model for colorectal ESD duration &lt;60 minutes (c-statistic 0.70, 95% CI 0.62–0.77), but this model was limited due to dichotomization of the outcome and a relatively low frequency (14%) of ESDs completed &lt;60 minutes in the Dutch centers. The model was more useful with a dichotomization cut-off of 120 minutes (c-statistic: 0.75; 88% and 17% of “easy” and “very difficult” ESDs completed &lt;120 minutes, respectively). To predict ESD duration as continuous outcome, we developed and validated the six-variable cESD-TIME formula (https://cesdtimeformula.shinyapps.io/calculator/; optimism-corrected R2=61%; R2=66% after recalibration of the slope).Conclusions We provided two useful tools for predicting colorectal ESD duration at Western centers. Further improvements and validations are encouraged with potential local adaptation to optimize time planning

    Cerebral processing of voice gender studied using a continuous carryover fMRI design

    Get PDF
    Normal listeners effortlessly determine a person's gender by voice, but the cerebral mechanisms underlying this ability remain unclear. Here, we demonstrate 2 stages of cerebral processing during voice gender categorization. Using voice morphing along with an adaptation-optimized functional magnetic resonance imaging design, we found that secondary auditory cortex including the anterior part of the temporal voice areas in the right hemisphere responded primarily to acoustical distance with the previously heard stimulus. In contrast, a network of bilateral regions involving inferior prefrontal and anterior and posterior cingulate cortex reflected perceived stimulus ambiguity. These findings suggest that voice gender recognition involves neuronal populations along the auditory ventral stream responsible for auditory feature extraction, functioning in pair with the prefrontal cortex in voice gender perception

    Clinical significance of stromal apoptosis in colorectal cancer

    Get PDF
    BackgroundEpithelial and stromal cells play an important role in the development of colorectal cancer (CRC). We aimed to determine the prognostic significance of both epithelial and stromal cell apoptosis in CRC.MethodsTotal apoptosis was determined by caspase-3 activity measurements in protein homogenates of CRC specimens and adjacent normal mucosa of 211 CRC patients. Epithelial apoptosis was determined by an ELISA specific for a caspase-3-degraded cytokeratin 18 product, the M30 antigen. Stromal apoptosis was determined from the ratio between total and epithelial apoptosis.ResultsEpithelial and stromal apoptosis, as well as total apoptosis, were significantly higher in CRC compared with corresponding adjacent normal mucosa. Low total tumour apoptosis (&lt; or = median caspase-3 activity) was associated with a significantly worse disease recurrence (hazard ratio (HR), 95% confidence interval (95% CI): 1.77 (1.05-3.01)), independent of clinocopathological parameters. Epithelial apoptosis was not associated with clinical outcome. In contrast, low stromal apoptosis (&lt; or = median caspase-3/M30) was found to be an independent prognostic factor for overall survival, disease-free survival and disease recurrence, with HRs (95% CI) of 1.66 (1.17-2.35), 1.62 (1.15-2.29) and 1.69 (1.01-2.85), respectively.InterpretationStromal apoptosis, in contrast to epithelial apoptosis, is an important factor with respect to survival and disease-recurrence in CRC

    Hemispheric Asymmetries in Speech Perception: Sense, Nonsense and Modulations

    Get PDF
    Background: The well-established left hemisphere specialisation for language processing has long been claimed to be based on a low-level auditory specialization for specific acoustic features in speech, particularly regarding 'rapid temporal processing'.Methodology: A novel analysis/synthesis technique was used to construct a variety of sounds based on simple sentences which could be manipulated in spectro-temporal complexity, and whether they were intelligible or not. All sounds consisted of two noise-excited spectral prominences (based on the lower two formants in the original speech) which could be static or varying in frequency and/or amplitude independently. Dynamically varying both acoustic features based on the same sentence led to intelligible speech but when either or both acoustic features were static, the stimuli were not intelligible. Using the frequency dynamics from one sentence with the amplitude dynamics of another led to unintelligible sounds of comparable spectro-temporal complexity to the intelligible ones. Positron emission tomography (PET) was used to compare which brain regions were active when participants listened to the different sounds.Conclusions: Neural activity to spectral and amplitude modulations sufficient to support speech intelligibility (without actually being intelligible) was seen bilaterally, with a right temporal lobe dominance. A left dominant response was seen only to intelligible sounds. It thus appears that the left hemisphere specialisation for speech is based on the linguistic properties of utterances, not on particular acoustic features

    fMRI scanner noise interaction with affective neural processes

    Get PDF
    The purpose of the present study was the investigation of interaction effects between functional MRI scanner noise and affective neural processes. Stimuli comprised of psychoacoustically balanced musical pieces, expressing three different emotions (fear, neutral, joy). Participants (N=34, 19 female) were split into two groups, one subjected to continuous scanning and another subjected to sparse temporal scanning that features decreased scanner noise. Tests for interaction effects between scanning group (sparse/quieter vs continuous/noisier) and emotion (fear, neutral, joy) were performed. Results revealed interactions between the affective expression of stimuli and scanning group localized in bilateral auditory cortex, insula and visual cortex (calcarine sulcus). Post-hoc comparisons revealed that during sparse scanning, but not during continuous scanning, BOLD signals were significantly stronger for joy than for fear, as well as stronger for fear than for neutral in bilateral auditory cortex. During continuous scanning, but not during sparse scanning, BOLD signals were significantly stronger for joy than for neutral in the left auditory cortex and for joy than for fear in the calcarine sulcus. To the authors' knowledge, this is the first study to show a statistical interaction effect between scanner noise and affective processes and extends evidence suggesting scanner noise to be an important factor in functional MRI research that can affect and distort affective brain processes

    Transanal minimally invasive surgery (TAMIS) versus endoscopic submucosal dissection (ESD) for resection of non-pedunculated rectal lesions (TRIASSIC study):study protocol of a European multicenter randomised controlled trial

    Get PDF
    BACKGROUND: In the recent years two innovative approaches have become available for minimally invasive en bloc resections of large non-pedunculated rectal lesions (polyps and early cancers). One is Transanal Minimally Invasive Surgery (TAMIS), the other is Endoscopic Submucosal Dissection (ESD). Both techniques are standard of care, but a direct randomised comparison is lacking. The choice between either of these procedures is dependent on local expertise or availability rather than evidence-based. The European Society for Endoscopy has recommended that a comparison between ESD and local surgical resection is needed to guide decision making for the optimal approach for the removal of large rectal lesions in Western countries. The aim of this study is to directly compare both procedures in a randomised setting with regard to effectiveness, safety and perceived patient burden. METHODS: Multicenter randomised trial in 15 hospitals in the Netherlands. Patients with non-pedunculated lesions > 2 cm, where the bulk of the lesion is below 15 cm from the anal verge, will be randomised between either a TAMIS or an ESD procedure. Lesions judged to be deeply invasive by an expert panel will be excluded. The primary endpoint is the cumulative local recurrence rate at follow-up rectoscopy at 12 months. Secondary endpoints are: 1) Radical (R0-) resection rate; 2) Perceived burden and quality of life; 3) Cost effectiveness at 12 months; 4) Surgical referral rate at 12 months; 5) Complication rate; 6) Local recurrence rate at 6 months. For this non-inferiority trial, the total sample size of 198 is based on an expected local recurrence rate of 3% in the ESD group, 6% in the TAMIS group and considering a difference of less than 6% to be non-inferior. DISCUSSION: This is the first European randomised controlled trial comparing the effectiveness and safety of TAMIS and ESD for the en bloc resection of large non-pedunculated rectal lesions. This is important as the detection rate of these adenomas is expected to further increase with the introduction of colorectal screening programs throughout Europe. This study will therefore support an optimal use of healthcare resources in the future. TRIAL REGISTRATION: Netherlands Trial Register, NL7083 , 06 July 2018
    corecore