351 research outputs found

    The significance of sample mass in the analysis of steroid estrogens in sewage sludges and the derivation of partition coefficients in wastewaters

    Get PDF
    Optimization of an analytical method for determination of steroid estrogens, through minimizing sample size, resulted in recoveries >84%, with relative standard deviations <3% and demonstrated the significance of sample size on method performance. Limits of detection were 2.1–5.3 ng/g. Primary sludges had estrogen concentrations of up to one order of magnitude less than those found in biological sludges (up to 994 ng/g). However, partition coefficients were higher in primary sludges (except estriol), with the most hydrophobic compound (ethinylestradiol) exhibiting the highest Kp value, information which may be of value to those involved in modeling removal during wastewater treatment

    The effectiveness of anaerobic digestion in removing estrogens and nonylphenol ethoxylates

    Get PDF
    This is the post-print version of the final paper published in Journal of Hazardous Materials. The published article is available from the link below. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. Copyright @ 2011 Elsevier B.V.The fate and behaviour of two groups of endocrine disrupting chemicals, steroid estrogens and nonylphenol ethoxylates, have been evaluated during the anaerobic digestion of primary and mixed sewage sludge under mesophilic and thermophilic conditions. Digestion occurred over six retention times, in laboratory scale reactors, treating sludges collected from a sewage treatment works in the United Kingdom. It has been established that sludge concentrations of both groups of compounds demonstrated temporal variations and that concentrations in mixed sludge were influenced by the presence of waste activated sludge as a result of transformations during aerobic treatment. The biodegradation of total steroid estrogens was >50% during primary sludge digestion with lower removals observed for mixed sludge, which reflected bulk organic solids removal efficiencies. The removal of nonylphenol ethoxylates was greater in mixed sludge digestion (>58%) compared with primary sludge digestion and did not reflect bulk organic removal efficiencies. It is apparent that anaerobic digestion reduces the concentrations of these compounds, and would therefore be expected to confer a degree of protection against exposure and transfer of both groups of compounds to the receiving/re-use environment.Thames Water, Yorkshire Water, and EPSRC

    Association of plasma GFAP with elevated brain amyloid is dependent on severity of white matter lesions in an Asian cognitively impaired cohort

    Get PDF
    INTRODUCTION: While elevated blood glial fibrillary acidic protein (GFAP) has been associated with brain amyloid pathology, whether this association occurs in populations with high cerebral small vessel disease (CSVD) concomitance remains unclear. METHODS: Using a Singapore-based cohort of cognitively impaired subjects, we assessed associations between plasma GFAP and neuroimaging measures of brain amyloid and CSVD, including white matter hyperintensities (WMH). We also examined the diagnostic performance of plasma GFAP in detecting brain amyloid beta positivity (Aβ+). RESULTS: When stratified by WMH status, elevated brain amyloid was associated with higher plasma GFAP only in the WMH– group (β = 0.383; P &lt; 0.001). The diagnostic performance of plasma GFAP in identifying Aβ+ was significantly higher in the WMH– group (area under the curve [AUC] = 0.896) than in the WMH+ group (AUC = 0.712, P = 0.008). DISCUSSION: The biomarker utility of plasma GFAP in detecting brain amyloid pathology is dependent on the severity of concomitant WMH. Highlight: Glial fibrillary acidic protein (GFAP)’s association with brain amyloid is unclear in populations with high cerebral small vessel disease (CSVD). Plasma GFAP was measured in a cohort with CSVD and brain amyloid. Plasma GFAP was better in detecting amyloid in patients with low CSVD versus high CSVD. Biomarker utility of GFAP in detecting brain amyloid depends on the severity of CSVD.</p

    Determination of steroid estrogens in wastewater by high performance liquid chromatography-tandem mass spectrometry

    Get PDF
    This paper discusses the requirement for, and presents an analytical procedure for, the determination of four unconjugated steroid hormones and a conjugated steroid (estrone-3-sulfate) in wastewaters. The method quantifies the steroids by LC/MS/MS following solid phase extraction and a two stage clean-up procedure. Samples were extracted using C18 cartridges and eluates were then purified by gel permeation chromatography, followed by a further clean-up step on an aminopropyl cartridge. The limits of detection achieved were 0.2 ng l-1 for estriol, 17β-estradiol and 17α-ethinylestradiol, and 0.1 ng l-1 for estrone and the conjugate. The robustness of the method was demonstrated by achieving recoveries of >83% for all steroids in settled sewage and final effluent samples with relative standard deviations of 0.5 - 12%. The method was used to analyse a range of samples from a wastewater treatment works in south east England which demonstrated a >80% removal for estrone, estradiol and estriol with little impact on concentrations of ethinylestradiol or the conjugate

    Approximate k-state solutions to the Dirac-Yukawa problem based on the spin and pseudospin symmetry

    Full text link
    Using an approximation scheme to deal with the centrifugal (pseudo-centrifugal) term, we solve the Dirac equation with the screened Coulomb (Yukawa) potential for any arbitrary spin-orbit quantum number {\kappa}. Based on the spin and pseudospin symmetry, analytic bound state energy spectrum formulas and their corresponding upper- and lower-spinor components of two Dirac particles are obtained using a shortcut of the Nikiforov-Uvarov method. We find a wide range of permissible values for the spin symmetry constant C_{s} from the valence energy spectrum of particle and also for pseudospin symmetry constant C_{ps} from the hole energy spectrum of antiparticle. Further, we show that the present potential interaction becomes less (more) attractive for a long (short) range screening parameter {\alpha}. To remove the degeneracies in energy levels we consider the spin and pseudospin solution of Dirac equation for Yukawa potential plus a centrifugal-like term. A few special cases such as the exact spin (pseudospin) symmetry Dirac-Yukawa, the Yukawa plus centrifugal-like potentials, the limit when {\alpha} becomes zero (Coulomb potential field) and the non-relativistic limit of our solution are studied. The nonrelativistic solutions are compared with those obtained by other methods.Comment: 21 pages, 6 figure

    A CsI(Tl) Scintillating Crystal Detector for the Studies of Low Energy Neutrino Interactions

    Get PDF
    Scintillating crystal detector may offer some potential advantages in the low-energy, low-background experiments. A 500 kg CsI(Tl) detector to be placed near the core of Nuclear Power Station II in Taiwan is being constructed for the studies of electron-neutrino scatterings and other keV-MeV range neutrino interactions. The motivations of this detector approach, the physics to be addressed, the basic experimental design, and the characteristic performance of prototype modules are described. The expected background channels and their experimental handles are discussed.Comment: 34 pages, 11 figures, submitted to Nucl. Instrum. Method

    Photoproduction of D±D^{*\pm} mesons associated with a leading neutron

    Full text link
    The photoproduction of D±(2010)D^{*\pm} (2010) mesons associated with a leading neutron has been observed with the ZEUS detector in epep collisions at HERA using an integrated luminosity of 80 pb1^{-1}. The neutron carries a large fraction, {xL>0.2x_L>0.2}, of the incoming proton beam energy and is detected at very small production angles, {θn<0.8\theta_n<0.8 mrad}, an indication of peripheral scattering. The DD^* meson is centrally produced with pseudorapidity {η1.9|\eta| 1.9 GeV}, which is large compared to the average transverse momentum of the neutron of 0.22 GeV. The ratio of neutron-tagged to inclusive DD^* production is 8.85±0.93(stat.)0.61+0.48(syst.)%8.85\pm 0.93({\rm stat.})^{+0.48}_{-0.61}({\rm syst.})\% in the photon-proton center-of-mass energy range {130<W<280130 <W<280 GeV}. The data suggest that the presence of a hard scale enhances the fraction of events with a leading neutron in the final state.Comment: 28 pages, 4 figures, 2 table

    Observation of isolated high-E_T photons in deep inelastic scattering

    Get PDF
    First measurements of cross sections for isolated prompt photon production in deep inelastic ep scattering have been made using the ZEUS detector at the HERA electron-proton collider using an integrated luminosity of 121 pb^-1. A signal for isolated photons in the transverse energy and rapidity ranges 5 < E_T^gamma < 10 GeV and -0.7 < eta^gamma < 0.9 was observed for virtualities of the exchanged photon of Q^2 > 35 GeV^2. Cross sections are presented for inclusive prompt photons and for those accompanied by a single jet in the range E_T^jet \geq 6 GeV and -1.5 \leq eta^jet < 1.8. Calculations at order alpha^3alpha_s describe the data reasonably well.Comment: 16 pages, 5 figure
    corecore