106 research outputs found

    Conformal Antenna Array for Millimeter-Wave Communications: Performance Evaluation

    Full text link
    In this paper, we study the influence of the radius of a cylindrical supporting structure on radiation properties of a conformal millimeter-wave antenna array. Bent antenna array structures on cylindrical surfaces may have important applications in future mobile devices. Small radii may be needed if the antenna is printed on the edges of mobile devices and in items which human beings are wearing, such as wrist watches, bracelets and rings. The antenna under study consists of four linear series-fed arrays of four patch elements and is operating at 58.8 GHz with linear polarization. The antenna array is fabricated on polytetrafluoroethylene substrate with thickness of 0.127 mm due to its good plasticity properties and low losses. Results for both planar and conformal antenna arrays show rather good agreement between simulation and measurements. The results show that conformal antenna structures allow achieving large angular coverage and may allow beam-steering implementations if switches are used to select between different arrays around a cylindrical supporting structure.Comment: Keywords: conformal antenna, millimeter-wave communications, patch antenna array. 11 pages, 10 figures, 1 tabl

    The 1991 WMO ozone sonde intercomparison

    Get PDF
    The WMO ozone sonde intercomparison was held at Vanscoy, Saskatchewan from May 13 to May 24, 1991. The purpose of the intercomparison is to evaluate the performance of various ozone sonde types used operationally in the Global Ozone Observing System and to ensure that the accuracy and precision of the measurements are sufficient to detect long-term trends in stratospheric ozone. The intercomparison was sponsored by WMO and hosted by the Atmospheric Environment Service (AES) of Canada. It was attended by scientists from six countries: Canada, Finland, Germany, India, Japan and USA. A total of 10 balloon payloads were launched each carrying 7 or 8 sondes for a total of 67 successful ozone sonde flights. The payloads were carried to altitudes between 35 and 40 km where the flights terminated by balloon burst. Results of the profile measurements made during the series of the profile measurements made during the series of flight are used to determine statistically meaningful evaluations of the different sonde types. A description of the payload and the different ozone sondes is given. Preliminary results of the profile measurements and an evaluation of the performance of the sonde types are presented

    Simulations of column-averaged CO_2 and CH_4 using the NIES TM with a hybrid sigma-isentropic (σ-θ) vertical coordinate

    Get PDF
    We have developed an improved version of the National Institute for Environmental Studies (NIES) three-dimensional chemical transport model (TM) designed for accurate tracer transport simulations in the stratosphere, using a hybrid sigma-isentropic (σ-θ) vertical coordinate that employs both terrain-following and isentropic parts switched smoothly around the tropopause. The air-ascending rate was derived from the effective heating rate and was used to simulate vertical motion in the isentropic part of the grid (above level 350 K), which was adjusted to fit to the observed age of the air in the stratosphere. Multi-annual simulations were conducted using the NIES TM to evaluate vertical profiles and dry-air column-averaged mole fractions of CO_2 and CH_4. Comparisons with balloon-borne observations over Sanriku (Japan) in 2000–2007 revealed that the tracer transport simulations in the upper troposphere and lower stratosphere are performed with accuracies of ~5% for CH_4 and SF_6, and ~1% for CO_2 compared with the observed volume-mixing ratios. The simulated column-averaged dry air mole fractions of atmospheric carbon dioxide (XCO_2) and methane (XCH_4) were evaluated against daily ground-based high-resolution Fourier Transform Spectrometer (FTS) observations measured at twelve sites of the Total Carbon Column Observing Network (TCCON) (Bialystok, Bremen, Darwin, Garmisch, Izaña, Lamont, Lauder, Orleans, Park Falls, Sodankylä, Tsukuba, and Wollongong) between January 2009 and January 2011. The comparison shows the model's ability to reproduce the site-dependent seasonal cycles as observed by TCCON, with correlation coefficients typically on the order 0.8–0.9 and 0.4–0.8 for XCO_2 and XCH_4, respectively, and mean model biases of ±0.2% and ±0.5%, excluding Sodankylä, where strong biases are found. The ability of the model to capture the tracer total column mole fractions is strongly dependent on the model's ability to reproduce seasonal variations in tracer concentrations in the planetary boundary layer (PBL). We found a marked difference in the model's ability to reproduce near-surface concentrations at sites located some distance from multiple emission sources and where high emissions play a notable role in the tracer's budget. Comparisons with aircraft observations over Surgut (West Siberia), in an area with high emissions of methane from wetlands, show contrasting model performance in the PBL and in the free troposphere. Thus, the PBL is another critical region for simulating the tracer total column mole fractions

    Methane retrievals from Greenhouse Gases Observing Satellite (GOSAT) shortwave infrared measurements: Performance comparison of proxy and physics retrieval algorithms

    Get PDF
    We compare two conceptually different methods for determining methane column-averaged mixing ratios image from Greenhouse Gases Observing Satellite (GOSAT) shortwave infrared (SWIR) measurements. These methods account differently for light scattering by aerosol and cirrus. The proxy method retrieves a CO_2 column which, in conjunction with prior knowledge on CO_2 acts as a proxy for scattering effects. The physics-based method accounts for scattering by retrieving three effective parameters of a scattering layer. Both retrievals are validated on a 19-month data set using ground-based X_CH_4 at 12 stations of the Total Carbon Column Observing Network (TCCON), showing comparable performance: for the proxy retrieval we find station-dependent retrieval biases from −0.312% to 0.421% of X_CH_4 a standard deviation of 0.22% and a typical precision of 17 ppb. The physics method shows biases between −0.836% and −0.081% with a standard deviation of 0.24% and a precision similar to the proxy method. Complementing this validation we compared both retrievals with simulated methane fields from a global chemistry-transport model. This identified shortcomings of both retrievals causing biases of up to 1ings and provide a satisfying validation of any methane retrieval from space-borne SWIR measurements, in our opinion it is essential to further expand the network of TCCON stations

    Heterogeneity of Colorectal Cancer Risk Factors by Anatomical Subsite in 10 European Countries : A Multinational Cohort Study

    Get PDF
    BACKGROUND & AIMS: Colorectal cancer located at different anatomical subsites may have distinct etiologies and risk factors. Previous studies that have examined this hypothesis have yielded inconsistent results, possibly because most studies have been of insufficient size to identify heterogeneous associations with precision. METHODS: In the European Prospective Investigation into Cancer and Nutrition study, we used multivariable joint Cox proportional hazards models, which accounted for tumors at different anatomical sites (proximal colon, distal colon, and rectum) as competing risks, to examine the relationships between 14 established/suspected lifestyle, anthropometric, and reproductive/menstrual risk factors with colorectal cancer risk. Heterogeneity across sites was tested using Wald tests. RESULTS: After a median of 14.9 years of follow-up of 521,330 men and women, 6291 colorectal cancer cases occurred. Physical activity was related inversely to proximal colon and distal colon cancer, but not to rectal cancer (P heterogeneity = .03). Height was associated positively with proximal and distal colon cancer only, but not rectal cancer (P heterogeneity = .0001). For men, but not women, heterogeneous relationships were observed for body mass index (P heterogeneity = .008) and waist circumference (P heterogeneity = .03), with weaker positive associations found for rectal cancer, compared with proximal and distal colon cancer. Current smoking was associated with a greater risk of rectal and proximal colon cancer, but not distal colon cancer (P heterogeneity = .05). No heterogeneity by anatomical site was found for alcohol consumption, diabetes, nonsteroidal anti-inflammatory drug use, and reproductive/menstrual factors. CONCLUSIONS: The relationships between physical activity, anthropometry, and smoking with colorectal cancer risk differed by subsite, supporting the hypothesis that tumors in different anatomical regions may have distinct etiologies.Peer reviewe

    Photo-affinity labelling and biochemical analyses identify the target of trypanocidal simplified natural product analogues

    Get PDF
    This work was supported by the Leverhulme Trust (Grant number RL2012-025). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.Current drugs to treat African sleeping sickness are inadequate and new therapies are urgently required. As part of a medicinal chemistry programme based upon the simplification of acetogenin-type ether scaffolds, we previously reported the promising trypanocidal activity of compound 1 , a bis-tetrahydropyran 1,4-triazole (B-THP-T) inhibitor. This study aims to identify the protein target(s) of this class of compound in Trypanosoma brucei to understand its mode of action and aid further structural optimisation. We used compound 3 , a diazirine- and alkyne-containing bi-functional photo-affinity probe analogue of our lead B-THP-T, compound 1 , to identify potential targets of our lead compound in the procyclic form T. brucei. Bi-functional compound 3 was UV cross-linked to its target(s) in vivo and biotin affinity or Cy5.5 reporter tags were subsequently appended by Cu(II)-catalysed azide-alkyne cycloaddition. The biotinylated protein adducts were isolated with streptavidin affinity beads and subsequent LC-MSMS identified the FoF1-ATP synthase (mitochondrial complex V) as a potential target. This target identification was confirmed using various different approaches. We show that (i) compound 1 decreases cellular ATP levels (ii) by inhibiting oxidative phosphorylation (iii) at the FoF1-ATP synthase. Furthermore, the use of GFP-PTP-tagged subunits of the FoF1-ATP synthase, shows that our compounds bind specifically to both the α- and β-subunits of the ATP synthase. The FoF1-ATP synthase is a target of our simplified acetogenin-type analogues. This mitochondrial complex is essential in both procyclic and bloodstream forms of T. brucei and its identification as our target will enable further inhibitor optimisation towards future drug discovery. Furthermore, the photo-affinity labeling technique described here can be readily applied to other drugs of unknown targets to identify their modes of action and facilitate more broadly therapeutic drug design in any pathogen or disease model.Publisher PDFPeer reviewe
    • …
    corecore