24 research outputs found

    Strain sensitivity of carbon nanotube cement-based composites for structural health monitoring

    Get PDF
    Cement-based smart sensors appear particularly suitable for monitoring applications, due to their self-sensing abilities, their ease of use, and their numerous possible field applications. The addition of conductive carbon nanofillers into a cementitious matrix provides the material with piezoresistive characteristics and enhanced sensitivity to mechanical alterations. The strain-sensing ability is achieved by correlating the variation of external loads or deformations with the variation of specific electrical parameters, such as the electrical resistance. Among conductive nanofillers, carbon nanotubes (CNTs) have shown promise for the fabrication of self-monitoring composites. However, some issues related to the filler dispersion and the mix design of cementitious nanoadded materials need to be further investigated. For instance, a small difference in the added quantity of a specific nanofiller in a cement-matrix composite can substantially change the quality of the dispersion and the strain sensitivity of the resulting material. The present research focuses on the strain sensitivity of concrete, mortar and cement paste sensors fabricated with different amounts of carbon nanotube inclusions. The aim of the work is to investigate the quality of dispersion of the CNTs in the aqueous solutions, the physical properties of the fresh mixtures, the electromechanical properties of the hardened materials, and the sensing properties of the obtained transducers. Results show that cement-based sensors with CNT inclusions, if properly implemented, can be favorably applied to structural health monitoring

    Glass optical fibre sensors for detection of through thickness moisture diffusion in glass reinforced composites under hostile environments

    Get PDF
    A combination of evanescent wave optical sensors (EWOSs) and fibre Bragg gratings (FBGs) was embedded in an epoxy vinyl ester and an epoxy vinyl ester based glass reinforced polymer (GRP) composite to measure fluid ingress that would result in degradation under hostile conditions. Samples were subjected to accelerated aging in the form of single sided exposure to simulated sea water at 1208C in a pressurised stainless steel vessel. Low cost EWOSs were prepared from a standard multimode glass optical fibre and compared to commercially available FBGs. Both sensors were able to detect the early stage of moisture diffusion into the GRP matrix. The evanescent sensors showed a reduction in the transmitted signal intensity between 1500 and 1650 nm with an increasing exposure time due to a change in the optical properties of the polymer, whereas a peak shift was observed for the FBGs due to the swelling of the resin with the absorption of water. Additionally, the glass optical fibre sensors were embedded in a configuration that allowed the extent of diffusion through the thickness of the GRPs to be monitored, with the fibres in the closest position to the exposure face showing a greater signal change than those positioned further away

    Enhancing Osteoconduction of PLLA-Based Nanocomposite Scaffolds for Bone Regeneration Using Different Biomimetic Signals to MSCs

    Get PDF
    In bone engineering, the adhesion, proliferation and differentiation of mesenchymal stromal cells rely on signaling from chemico-physical structure of the substrate, therefore prompting the design of mimetic “extracellular matrix”-like scaffolds. In this study, three-dimensional porous poly-L-lactic acid (PLLA)-based scaffolds have been mixed with different components, including single walled carbon nanotubes (CNT), micro-hydroxyapatite particles (HA), and BMP2, and treated with plasma (PT), to obtain four different nanocomposites: PLLA + CNT, PLLA + CNTHA, PLLA + CNT + HA + BMP2 and PLLA + CNT + HA + PT. Adult bone marrow mesenchymal stromal cells (MSCs) were derived from the femur of orthopaedic patients, seeded on the scaffolds and cultured under osteogenic induction up to differentiation and mineralization. The release of specific metabolites and temporal gene expression profiles of marrow-derived osteoprogenitors were analyzed at definite time points, relevant to in vitro culture as well as in vivo differentiation. As a result, the role of the different biomimetic components added to the PLLA matrix was deciphered, with BMP2-added scaffolds showing the highest biomimetic activity on cells differentiating to mature osteoblasts. The modification of a polymeric scaffold with reinforcing components which also work as biomimetic cues for cells can effectively direct osteoprogenitor cells differentiation, so as to shorten the time required for mineralization

    Strain sensitivity of carbon nanotube cement-based composites for structural health monitoring

    Get PDF
    Cement-based smart sensors appear particularly suitable for monitoring applications, due to their self-sensing abilities, their ease of use, and their numerous possible field applications. The addition of conductive carbon nanofillers into a cementitious matrix provides the material with piezoresistive characteristics and enhanced sensitivity to mechanical alterations. The strain-sensing ability is achieved by correlating the variation of external loads or deformations with the variation of specific electrical parameters, such as the electrical resistance. Among conductive nanofillers, carbon nanotubes (CNTs) have shown promise for the fabrication of self-monitoring composites. However, some issues related to the filler dispersion and the mix design of cementitious nanoadded materials need to be further investigated. For instance, a small difference in the added quantity of a specific nanofiller in a cement-matrix composite can substantially change the quality of the dispersion and the strain sensitivity of the resulting material. The present research focuses on the strain sensitivity of concrete, mortar and cement paste sensors fabricated with different amounts of carbon nanotube inclusions. The aim of the work is to investigate the quality of dispersion of the CNTs in the aqueous solutions, the physical properties of the fresh mixtures, the electromechanical properties of the hardened materials, and the sensing properties of the obtained transducers. Results show that cement-based sensors with CNT inclusions, if properly implemented, can be favorably applied to structural health monitoring.This proceeding is published as Antonella D'Alessandro, Filippo Ubertini, Simon Laflamme, Marco Rallini, Annibale L. Materazzi, Josè M. Kenny, "Strain sensitivity of carbon nanotube cement-based composites for structural health monitoring", Proc. SPIE 9803, Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2016, 980319 (20 April 2016); doi: 10.1117/12.2218905. Posted with permission.</p

    Mechanotransduction: Tuning Stem Cells Fate

    No full text
    It is a general concern that the success of regenerative medicine-based applications is based on the ability to recapitulate the molecular events that allow stem cells to repair the damaged tissue/organ. To this end biomaterials are designed to display properties that, in a precise and physiological-like fashion, could drive stem cell fate both in vitro and in vivo. The rationale is that stem cells are highly sensitive to forces and that they may convert mechanical stimuli into a chemical response. In this review, we describe novelties on stem cells and biomaterials interactions with more focus on the implication of the mechanical stimulation named mechanotransduction

    Gallic Acid and Quercetin as Intelligent and Active Ingredients in Poly(vinyl alcohol) Films for Food Packaging

    No full text
    none7Gallic acid (GA) and quercetin (QC) were used as active ingredients in poly(vinyl alcohol) (PVA) film formulations obtained by solvent casting process. The effect of two different percentages (5 and 10 % wt.) on morphological behavior, thermal stability, optical, mechanical, and release properties of PVA were investigated, while migration with food stimulants and antioxidant properties were tested taking into account the final application as food packaging systems. The results showed how different dispersability in PVA water solutions gave different results in term of deformability (mean value of ε PVA/5GA = 280% and ε PVA/5QC = 255%, with 190% for neat PVA), comparable values for antioxidant activity at the high contents (Radical Scavenging Activity, RSA(%) PVA/10GA = 95 and RSA(%) PVA/10QC = 91) and different coloring attitude of the polymeric films. It was proved that GA, even if it represents the best antioxidant ingredient to be used with PVA and can be easily dispersed in water, it gives more rigid films in comparison to QC, that indeed was more efficient in tuning the deformability of the PVA films, due the presence of sole hydroxyl groups carrying agent. The deviation of the film coloring towards greenish tones for GA films and redness for QC films after 7 and within 21 days in the simulated conditions confirmed the possibility of using easy processable PVA films as active and intelligent films in food packaging.noneLuzi, Francesca; Pannucci, Elisa; Santi, Luca; Kenny, José Maria; Torre, Luigi; Bernini, Roberta; Puglia, DeboraLuzi, Francesca; Pannucci, Elisa; Santi, Luca; Kenny, José Maria; Torre, Luigi; Bernini, Roberta; Puglia, Debor
    corecore