274 research outputs found

    Pauli blocking of stimulated emission in a degenerate Fermi gas

    Full text link
    The Pauli exclusion principle in quantum mechanics has a profound influence on the structure of matter and on interactions between fermions. Almost 30 years ago it was predicted that the Pauli exclusion principle could lead to a suppression of spontaneous emission, and only recently several experiments confirmed this phenomenon. Here we report that this so-called Pauli blockade not only affects incoherent processes but also, more generally, coherently driven systems. It manifests itself as an intriguing sub-Doppler narrowing of a doubly-forbidden transition profile in an optically trapped Fermi gas of 3He^3\mathrm{He}. By actively pumping atoms out of the excited state, we break the coherence of the excitation and lift the narrowing effect, confirming the influence of Pauli blockade on the transition profile. This new insight into the interplay between quantum statistics and coherent driving is a promising development for future applications involving fermionic systems.Comment: 36 pages, 8 figure

    The alpha and helion particle charge radius difference from spectroscopy of quantum-degenerate helium

    Full text link
    Accurate spectroscopic measurements of calculable systems provide a powerful method for testing the Standard Model and extracting fundamental constants. Recently, spectroscopic measurements of finite nuclear size effects in normal and muonic hydrogen resulted in unexpectedly large adjustments of the proton charge radius and the Rydberg constant. We measured the 23S→21S2^3\mathrm{S}\rightarrow2^1\mathrm{S} transition frequency in a Fermi gas of 3^3He with an order of magnitude higher accuracy than before. Together with a previous measurement in a 4^4He Bose-Einstein condensate, a squared charge radius difference rh2−rα2=1.0757(15) fm2r^2_h - r^2_{\alpha} = 1.0757(15)\ \mathrm{fm^2} is determined between the helion and alpha particle. This measurement provides a benchmark with unprecedented accuracy for nuclear structure calculations. A deviation of 3.6σ\sigma is found with a determination (arXiv:2305.11679) based on spectroscopy of muonic helium ions.Comment: Paper and supplementary in total 13 pages and 5 figure

    Image guidance in neurosurgical procedures, the "Visages" point of view.

    Get PDF
    This paper gives an overview of the evolution of clinical neuroinformatics in the domain of neurosurgery. It shows how image guided neurosurgery (IGNS) is evolving according to the integration of new imaging modalities before, during and after the surgical procedure and how this acts as the premise of the Operative Room of the future. These different issues, as addressed by the VisAGeS INRIA/INSERM U746 research team (http://www.irisa.fr/visages), are presented and discussed in order to exhibit the benefits of an integrated work between physicians (radiologists, neurologists and neurosurgeons) and computer scientists to give adequate answers toward a more effective use of images in IGNS

    Magnetotransport properties depending on the nanostructure of Fe3O4 nanowires

    Get PDF
    We have studied the magnetic behaviour of Fe3O4 nanowires (NWs) with two different diameter ranges, above 150 nm and below 60 nm, made by electrodeposition techniques into a polymeric template. The nanowires were characterized using various techniques, in particular Mšossbauer and thermoelectrical power measurements. The stoichiometric distribution of Fe cations showed clearly the presence of the magnetite inverse spinel electronic structure. Structural analysis performed using high-resolution transmission electron microscopy revealed two kinds of nanowire morphologies depending on the size. For nanowires above 150 nm in diameter, a contiguous network of well-bound nanoparticles was obtained. Instead, with a diameter of 60 nm, a polycrystalline structure was observed. The largest nanowires presented a magnetoresistance (MR) greater than 10%, whereas the thinner nanowires had almost none

    Microwave frequency modulation to enhance Dissolution Dynamic Nuclear Polarization Dedicated to To Martial Rey, as a token of appreciation

    Get PDF
    Hyperpolarization by Dissolution Dynamic Nuclear Polarization is usually achieved by monochromatic microwave irradiation of the ESR spectrum of free radicals embedded in glasses at 1.2 K and 3.35 T. Hovav et al. (2014) have recently shown that by using frequency-modulated (rather than monochromatic) microwave irradiation one can improve DNP at 3.35 T in the temperature range 10-50 K. We show in this Letter that this is also true under Dissolution-DNP conditions at 1.2 K and 6.7 T. We demonstrate the many virtues of using frequency-modulated microwave irradiation: higher polarizations, faster build-up rates, lower radical concentrations, less paramagnetic broadening, more efficient cross-polarization, and less critical frequency adjustments. © 2014 The Authors. Published by Elsevier B.V

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    Comparative validation of single-shot optical techniques for laparoscopic 3-D surface reconstruction

    Get PDF
    Intra-operative imaging techniques for obtaining the shape and morphology of soft-tissue surfaces in vivo are a key enabling technology for advanced surgical systems. Different optical techniques for 3-D surface reconstruction in laparoscopy have been proposed, however, so far no quantitative and comparative validation has been performed. Furthermore, robustness of the methods to clinically important factors like smoke or bleeding has not yet been assessed. To address these issues, we have formed a joint international initiative with the aim of validating different state-of-the-art passive and active reconstruction methods in a comparative manner. In this comprehensive in vitro study, we investigated reconstruction accuracy using different organs with various shape and texture and also tested reconstruction robustness with respect to a number of factors like the pose of the endoscope as well as the amount of blood or smoke present in the scene. The study suggests complementary advantages of the different techniques with respect to accuracy, robustness, point density, hardware complexity and computation time. While reconstruction accuracy under ideal conditions was generally high, robustness is a remaining issue to be addressed. Future work should include sensor fusion and in vivo validation studies in a specific clinical context. To trigger further research in surface reconstruction, stereoscopic data of the study will be made publically available at www.open-CAS.com upon publication of the paper

    SAGES consensus recommendations on surgical video data use, structure, and exploration (for research in artificial intelligence, clinical quality improvement, and surgical education)

    Get PDF
    BACKGROUND: Surgery generates a vast amount of data from each procedure. Particularly video data provides significant value for surgical research, clinical outcome assessment, quality control, and education. The data lifecycle is influenced by various factors, including data structure, acquisition, storage, and sharing; data use and exploration, and finally data governance, which encompasses all ethical and legal regulations associated with the data. There is a universal need among stakeholders in surgical data science to establish standardized frameworks that address all aspects of this lifecycle to ensure data quality and purpose. METHODS: Working groups were formed, among 48 representatives from academia and industry, including clinicians, computer scientists and industry representatives. These working groups focused on: Data Use, Data Structure, Data Exploration, and Data Governance. After working group and panel discussions, a modified Delphi process was conducted. RESULTS: The resulting Delphi consensus provides conceptualized and structured recommendations for each domain related to surgical video data. We identified the key stakeholders within the data lifecycle and formulated comprehensive, easily understandable, and widely applicable guidelines for data utilization. Standardization of data structure should encompass format and quality, data sources, documentation, metadata, and account for biases within the data. To foster scientific data exploration, datasets should reflect diversity and remain adaptable to future applications. Data governance must be transparent to all stakeholders, addressing legal and ethical considerations surrounding the data. CONCLUSION: This consensus presents essential recommendations around the generation of standardized and diverse surgical video databanks, accounting for multiple stakeholders involved in data generation and use throughout its lifecycle. Following the SAGES annotation framework, we lay the foundation for standardization of data use, structure, and exploration. A detailed exploration of requirements for adequate data governance will follow
    • 

    corecore