6 research outputs found

    Scientific drilling projects in ancient lakes: integrating geological and biological histories

    Get PDF
    Sedimentary sequences in ancient or long-lived lakes can reach several thousands of meters in thickness and often provide an unrivalled perspective of the lake's regional climatic, environmental, and biological history. Over the last few years, deep drilling projects in ancient lakes became increasingly multi- and interdisciplinary, as, among others, seismological, sedimentological, biogeochemical, climatic, environmental, paleontological, and evolutionary information can be obtained from sediment cores. However, these multi- and interdisciplinary projects pose several challenges. The scientists involved typically approach problems from different scientific perspectives and backgrounds, and setting up the program requires clear communication and the alignment of interests. One of the most challenging tasks, besides the actual drilling operation, is to link diverse datasets with varying resolution, data quality, and age uncertainties to answer interdisciplinary questions synthetically and coherently. These problems are especially relevant when secondary data, i.e., datasets obtained independently of the drilling operation, are incorporated in analyses. Nonetheless, the inclusion of secondary information, such as isotopic data from fossils found in outcrops or genetic data from extant species, may help to achieve synthetic answers. Recent technological and methodological advances in paleolimnology are likely to increase the possibilities of integrating secondary information, e.g., through molecular dating of molecular phylogenies. Some of the new approaches have started to revolutionize scientific drilling in ancient lakes, but at the same time, they also add a new layer of complexity to the generation and analysis of sediment core data. The enhanced opportunities presented by new scientific approaches to study the paleolimnological history of these lakes, therefore, come at the expense of higher logistic, communication, and analytical efforts. Here we review types of data that can be obtained in ancient lake drilling projects and the analytical approaches that can be applied to empirically and statistically link diverse datasets for creating an integrative perspective on geological and biological data. In doing so, we highlight strengths and potential weaknesses of new methods and analyses, and provide recommendations for future interdisciplinary deep drilling projects

    A ballistographic approach for continuous and non-obtrusive monitoring of movement in neonates

    Get PDF
    Continuously monitoring body movement in preterm infants can have important clinical applications since changes in movement-patterns can be a significant marker for clinical deteriorations including the onset of sepsis, seizures, and apneas. This paper proposes a system and method to monitor body movement of preterm infants in a clinical environment using ballistography. The ballistographic signal (BSG) is acquired using a thin and a film-like sensor that is placed underneath an infant. Manual annotations based on video-recordings served as a reference standard for identifying movement. We investigated the performance of multiple features, constructed from the BSG waveform, to discriminate movement from no movement based on data acquired from 10 preterm infants. Since routine cardiorespiratory monitoring is prone to movement artifacts, we also compared the application of these features on the simultaneously acquired cardiorespiratory waveforms, i.e., the electrocardiogram, the chest impedance, and the photoplethysmogram. The BSG-based-features consistently outperformed those based on the routinely acquired cardiorespiratory waveforms. The best performing BSG-based feature-the signal instability index-had a mean (standard deviation) effect size of 0.90 (0.06), as measured by the area under the receiver operating curve. The proposed system for monitoring body movement is robust to noise, non-obtrusive, and has high performance in clinical settings

    A ballistographic approach for continuous and non-obtrusive monitoring of movement in neonates

    No full text
    \u3cp\u3eContinuously monitoring body movement in preterm infants can have important clinical applications since changes in movement-patterns can be a significant marker for clinical deteriorations including the onset of sepsis, seizures, and apneas. This paper proposes a system and method to monitor body movement of preterm infants in a clinical environment using ballistography. The ballistographic signal (BSG) is acquired using a thin and a film-like sensor that is placed underneath an infant. Manual annotations based on video-recordings served as a reference standard for identifying movement. We investigated the performance of multiple features, constructed from the BSG waveform, to discriminate movement from no movement based on data acquired from 10 preterm infants. Since routine cardiorespiratory monitoring is prone to movement artifacts, we also compared the application of these features on the simultaneously acquired cardiorespiratory waveforms, i.e., the electrocardiogram, the chest impedance, and the photoplethysmogram. The BSG-based-features consistently outperformed those based on the routinely acquired cardiorespiratory waveforms. The best performing BSG-based feature-the signal instability index-had a mean (standard deviation) effect size of 0.90 (0.06), as measured by the area under the receiver operating curve. The proposed system for monitoring body movement is robust to noise, non-obtrusive, and has high performance in clinical settings.\u3c/p\u3

    Head orientation and electrode placement potentially influence fetal scalp ECG waveform

    No full text
    Background Fetal monitoring based on electrocardiographic (ECG) morphology is obtained from a single unipolar fetal scalp electrode. Ideally, it should be obtained from multiple leads, as ECG waveform depends on alignment between electrode and electrical heart axis. This alignment is unknown in fetuses. Besides, fetuses are surrounded by conductive media, which may influence ECG waveform. We explored the influence of electrode position and head orientation on ECG waveforms of unipolar and bipolar scalp ECGs recorded in air and in conductive medium. Methods We recorded ECGs in one adult subject at five different scalp positions in five different head orientations both in dry and immersed conditions. The ratio between T-amplitude and QRS-amplitude (T/QRS ratio) of unipolar and bipolar scalp ECGs was determined and compared between all conditions. Results In the dry condition, we observed in the unipolar leads little to no difference between different electrode positions (maximal T/QRS difference 0.00–0.01) and minor differences between head orientations (0.02–0.03), whereas bipolar leads showed no recognizable ECG signal at all. During the immersed condition, we found variation in the unipolar leads, both between electrode positions (maximal T/QRS difference 0.02–0.05) and between head orientations (0.03–0.06). Bipolar leads showed different ECG signals in contrasting head orientations. Conclusions Both unipolar and bipolar scalp lead-derived ECG waveforms are influenced by electrode position and head orientation when the subject is submerged in a conductive medium. Fetal monitoring based on single scalp lead ECG waveform might be suboptimal, as it lacks correction for fetal head orientation and electrode position

    Head orientation and electrode placement potentially influence fetal scalp ECG waveform

    Get PDF
    \u3cp\u3eBackground Fetal monitoring based on electrocardiographic (ECG) morphology is obtained from a single unipolar fetal scalp electrode. Ideally, it should be obtained from multiple leads, as ECG waveform depends on alignment between electrode and electrical heart axis. This alignment is unknown in fetuses. Besides, fetuses are surrounded by conductive media, which may influence ECG waveform. We explored the influence of electrode position and head orientation on ECG waveforms of unipolar and bipolar scalp ECGs recorded in air and in conductive medium. Methods We recorded ECGs in one adult subject at five different scalp positions in five different head orientations both in dry and immersed conditions. The ratio between T-amplitude and QRS-amplitude (T/QRS ratio) of unipolar and bipolar scalp ECGs was determined and compared between all conditions. Results In the dry condition, we observed in the unipolar leads little to no difference between different electrode positions (maximal T/QRS difference 0.00–0.01) and minor differences between head orientations (0.02–0.03), whereas bipolar leads showed no recognizable ECG signal at all. During the immersed condition, we found variation in the unipolar leads, both between electrode positions (maximal T/QRS difference 0.02–0.05) and between head orientations (0.03–0.06). Bipolar leads showed different ECG signals in contrasting head orientations. Conclusions Both unipolar and bipolar scalp lead-derived ECG waveforms are influenced by electrode position and head orientation when the subject is submerged in a conductive medium. Fetal monitoring based on single scalp lead ECG waveform might be suboptimal, as it lacks correction for fetal head orientation and electrode position.\u3c/p\u3
    corecore