21 research outputs found

    Temporal variability in shell mound formation at Albatross Bay, northern Australia

    Get PDF
    We report the results of 212 radiocarbon determinations from the archaeological excavation of 70 shell mound deposits in the Wathayn region of Albatross Bay, Australia. This is an intensive study of a closely co-located group of mounds within a geographically restricted area in a wider region where many more shell mounds have been reported. Valves from the bivalve Tegillarcca granosa were dated. The dates obtained are used to calculate rates of accumulation for the shell mound deposits. These demonstrate highly variable rates of accumulation both within and between mounds. We assess these results in relation to likely mechanisms of shell deposition and show that rates of deposition are affected by time-dependent processes both during the accumulation of shell deposits and during their subsequent deformation. This complicates the interpretation of the rates at which shell mound deposits appear to have accumulated. At Wathayn, there is little temporal or spatial consistency in the rates at which mounds accumulated. Comparisons between the Wathayn results and those obtained from shell deposits elsewhere, both in the wider Albatross Bay region and worldwide, suggest the need for caution when deriving behavioural inferences from shell mound deposition rates, and the need for more comprehensive sampling of individual mounds and groups of mounds

    Reduction of visual acuity decreases capacity to evaluate radiographic image quality

    Get PDF
    Aim: To determine the impact of reduced visual acuity on the evaluation of a test object and appendicular radiographs. Methods: Visual acuity was reduced by two different magnitudes using simulation glasses and compared to normal vision (no glasses). During phase one phantom images were produced for the purpose of counting objects by 13 observers and on phase 2 image appraisal of anatomical structures was performed on anonymized radiographic images by 7 observers. The monitors were calibrated (SMPTE RP133 test pattern) and the room lighting was maintained at 7 ±1 lux. Image display and data on grading were managed using ViewDEX (v.2.0) and the area under the visual grading characteristic (AUCVGC) was calculated using VGC Analyzer (v1.0.2). Inferential statistics were calculated using SPSS. Results: For the evaluation of appendicular radiographs the total interpretation time was longer when visual acuity was reduced with 2 pairs of simulation glasses (15.4 versus 8.9 min). Visual grading analysis showed that observers can lose the ability to detect anatomical and contrast differences when they have a simulated visual acuity reduction, being more challenging to differentiate low contrast details. No simulation glasses, compared to 1 pair gives an AUCVGC of 0.302 (0.280, 0.333), that decreases to 0.197 (0.175, 0.223) when using 2 pairs of glasses. Conclusions: Reduced visual acuity has a significant negative impact on the evaluation of test objects and clinical images. Further work is required to test the impact of reduced visual acuity on visual search, technical evaluation of a wider range of images as well as pathology detection/characterization performance
    corecore