27 research outputs found

    Utility of Pathology Imagebase for Standardization of Prostate Cancer Grading

    Get PDF
    Aims: Despite efforts to standardise grading of prostate cancer, even among experts there is still a considerable variation in grading practices. In this study we describe the use of Pathology Imagebase, a novel reference image library, for setting an international standard in prostate cancer grading. Methods and results: The International Society of Urological Pathology (ISUP) recently launched a reference image database supervised by experts. A panel of 24 international experts in prostate pathology reviewed independently microphotographs of 90 cases of prostate needle biopsies with cancer. A linear weighted kappa of 0.67 (95% confidence interval = 0.62-0.72) and consensus was reached in 50 cases. The interobserver weighted kappa varied from 0.48 to 0.89. The highest level of agreement was seen for Gleason score (GS) 3 + 3 = 6 (ISUP grade 1), while higher grades and particularly GS 4 + 3 = 7 (ISUP grade 3) showed considerable disagreement. Once a two-thirds majority was reached, images were moved automatically into a public database available for all ISUP members at www.isupweb.org. Non-members are able to access a limited number of cases. Conclusions: It is anticipated that the database will assist pathologists to calibrate their grading and, hence, decrease interobserver variability. It will also help to identify instances where definitions of grades need to be clarified

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Oklahoma Agricultural Experiment Station, Bulletin no. 462, November 1955: Creep-feeding spring calves

    No full text
    The Oklahoma Agricultural Experiment Station periodically issues revisions to its publications. The most current edition is made available. For access to an earlier edition, if available for this title, please contact the Oklahoma State University Library Archives by email at [email protected] or by phone at 405-744-6311

    Artificial intelligence assistance significantly improves Gleason grading of prostate biopsies by pathologists

    No full text
    The Gleason score is the most important prognostic marker for prostate cancer patients, but it suffers from significant observer variability. Artificial intelligence (AI) systems based on deep learning can achieve pathologist-level performance at Gleason grading. However, the performance of such systems can degrade in the presence of artifacts, foreign tissue, or other anomalies. Pathologists integrating their expertise with feedback from an AI system could result in a synergy that outperforms both the individual pathologist and the system. Despite the hype around AI assistance, existing literature on this topic within the pathology domain is limited. We investigated the value of AI assistance for grading prostate biopsies. A panel of 14 observers graded 160 biopsies with and without AI assistance. Using AI, the agreement of the panel with an expert reference standard increased significantly (quadratically weighted Cohen’s kappa, 0.799 vs. 0.872; p = 0.019). On an external validation set of 87 cases, the panel showed a significant increase in agreement with a panel of international experts in prostate pathology (quadratically weighted Cohen’s kappa, 0.733 vs. 0.786; p = 0.003). In both experiments, on a group-level, AI-assisted pathologists outperformed the unassisted pathologists and the standalone AI system. Our results show the potential of AI systems for Gleason grading, but more importantly, show the benefits of pathologist-AI synergy

    Intraductal Carcinoma Of The Prostate: Interobserver Reproducibility Survey Of 39 Urologic Pathologists.

    No full text
    The diagnosis of intraductal carcinoma (IDC) of the prostate remains subjective because 3 sets of diagnostic criteria are in use. An internet survey was compiled from 38 photomicrographs showing duct proliferations: 14 signed out as high-grade prostatic intraepithelial neoplasia (HGPIN), 17 IDC, and 7 invasive cribriform/ductal carcinoma. Each image was assessed for the presence of 9 histologic criteria ascribed to IDC. Thirty-nine respondents were asked to rate images as (1) benign/reactive, (2) HGPIN, (3) borderline between HGPIN and IDC, (4) IDC, or (5) invasive cribriform/ductal carcinoma. Intraclass correlation coefficient was 0.68. There was 70% overall agreement with HGPIN, 43% with IDC, and 73% with invasive carcinoma (P < .001, χ(2)). Respondents considered 19 (50%) of 38 cases as IDC candidates, of which 5 (26%) had a two-thirds consensus for IDC; two-thirds consensus for either borderline or IDC was reached in 9 (47%). Two-thirds consensus other than IDC was reached in the remaining 19 of 38 cases, with 15 supporting HGPIN and 4 supporting invasive carcinoma. Findings that differed across diagnostic categories were lumen-spanning neoplastic cells (P < .001), 2× benign duct diameters (P < .001), duct space contours (round, irregular, and branched) (P < .001), papillary growth (P = .048), dense cribriform or solid growth (both P = .023), and comedonecrosis (P = .015). When the 19 of 38 images that attained consensus for HGPIN or invasive carcinoma were removed from consideration, lack of IDC consensus was most often attributable to only loose cribriform growth (5/19), central nuclear maturation (5/19), or comedonecrosis (3/19). Of the 9 histologic criteria, only 1 retained significant correlation with a consensus diagnosis of IDC: the presence of solid areas (P = .038). One case that attained IDC consensus had less than 2× duct enlargement yet still had severe nuclear atypia and nucleomegaly. Six fold nuclear enlargement was not significant (P = .083), although no image had both 6× nuclei and papillary or loose cribriform growth: a combination postulated as sufficient criteria for IDC. Finally, 20.5% of respondents agreed that an isolated diagnosis of IDC on needle biopsy warrants definitive therapy, 20.5% disagreed, and 59.0% considered the decision to depend upon clinicopathologic variables. Although IDC diagnosis remains challenging, we propose these criteria: a lumen-spanning proliferation of neoplastic cells in preexisting ducts with a dense cribriform or partial solid growth pattern. Solid growth, in any part of the duct space, emerges as the most reproducible finding to rule in a diagnosis of IDC. Comedonecrosis is a rarer finding, but in most cases, it should rule in IDC. Duct space enlargement to greater than 2× the diameter of the largest, adjacent benign spaces is usually present in IDC, although there may be rare exceptions.18333-4
    corecore