288 research outputs found

    Designing a New Raster Sub-System for GRASS-7

    Get PDF
    The paper deals with a design of a new raster sub-system intended for modern GIS systems open for client and server operation, database connection and strong application interface (API). Motivation for such a design comes from the current state of API working in GRASS 6. If found attractive, the here presented design and its implementation (referred as RG7) may be integrated to the future new generation of the GRASS Geographical Information System version 7-8. The paper describes in details the concept of raster tiling, computer storage of rasters and basic raster access procedures. Finally, the paper gives a simple benchmarking experiment of random read access to raster files imported from the Spearfish dataset. The experiment compares the early implementation of RG7 with the current implementation of rasters in GRASS 6. As the result, the experiment shows the RG7 to be significantly faster than GRASS in random read access to large raster files

    Electrospray device

    Get PDF
    An electrospray device includes an electrospray emitter adapted to receive electrospray fluid; an extractor plate spaced from the electrospray emitter and having at least one aperture; and a power supply for applying a first voltage between the extractor plate and emitter for generating at least one Taylor cone emission through the aperture to create an electrospray plume from the electrospray fluid, the extractor plate as well as accelerator and shaping plates may include a porous, conductive medium for transporting and storing excess, accumulated electrospray fluid away from the aperture

    Complementarity of Δ opioid ligand pharmacophore and receptor models

    Full text link
    The elaboration of a pharmacophore model for the Δ opioid receptor selective ligand JOM-13 (Tyr–c[ D -Cys–Phe– D -Pen]OH) and the parallel, independent development of a structural model of the Δ receptor are summarized. Although the backbone conformation of JOM-13's tripeptide cycle is well defined, considerable conformational lability is evident in the Tyr 1 residue and in the Phe 3 side chain, key pharmacophore elements of the ligand. Replacement of these flexible features of the ligand by more conformationally restricted analogues and subsequent correlation of receptor binding and conformational properties allowed the number of possible binding conformations of JOM-13 to be reduced to two. Of these, one was chosen as more likely, based on its better superposition with other conformationally constrained Δ receptor ligands. Our model of the Δ opioid receptor, constructed using a general approach that we have developed for all rhodopsin-like G protein-coupled receptors, contains a large cavity within the transmembrane domain that displays excellent complementarity in both shape and polarity to JOM-13 and other Δ ligands. This binding pocket, however, cannot accommodate the conformer of JOM-13 preferred from analysis of ligands, alone. Rather, only the “alternate” allowed conformer, identified from analysis of the ligands but “disfavored” because it does not permit simultaneous superposition of all pharmacophore elements of JOM-13 with other Δ ligands, fits the binding site. These results argue against a simple view of a single, common fit to a receptor binding site and suggest, instead, that at least some binding site interactions of different ligands may differ. © 2000 John Wiley & Sons, Inc. Biopoly 51: 426–439, 1999Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/34323/1/5_ftp.pd

    Functional and Psychosocial Outcomes of Hand Transplantation Compared with Prosthetic Fitting in Below-Elbow Amputees:A Multicenter Cohort Study

    Get PDF
    BACKGROUND:Hand-transplantation and improvements in the field of prostheses opened new frontiers in restoring hand function in below-elbow amputees. Both concepts aim at restoring reliable hand function, however, the indications, advantages and limitations for each treatment must be carefully considered depending on level and extent of amputation. Here we report our findings of a multi-center cohort study comparing hand function and quality-of-life of people with transplanted versus prosthetic hands. METHODS:Hand function in amputees with either transplant or prostheses was tested with Action Research Arm Test (ARAT), Southampton Hand Assessment Procedure (SHAP) and the Disabilities of the Arm, Shoulder and Hand measure (DASH). Quality-of-life was compared with the Short-Form 36 (SF-36). RESULTS:Transplanted patients (n = 5) achieved a mean ARAT score of 40.86 ± 8.07 and an average SHAP score of 75.00 ± 11.06. Prosthetic patients (n = 7) achieved a mean ARAT score of 39.00 ± 3.61 and an average SHAP score of 75.43 ± 10.81. There was no significant difference between transplanted and prosthetic hands in ARAT, SHAP or DASH. While quality-of-life metrics were equivocal for four scales of the SF-36, transplanted patients reported significantly higher scores in "role-physical" (p = 0.006), "vitality" (p = 0.008), "role-emotional" (p = 0.035) and "mental-health" (p = 0.003). CONCLUSIONS:The indications for hand transplantation or prosthetic fitting in below-elbow amputees require careful consideration. As functional outcomes were not significantly different between groups, patient's best interests and the route of least harm should guide treatment. Due to the immunosuppressive side-effects, the indication for allotransplantation must still be restrictive, the best being bilateral amputees

    Block and gradient copoly(2-oxazoline) micelles : strikingly different on the inside

    Get PDF
    Herein, we provide a direct proof for differences in the micellar structure of amphiphilic diblock and gradient copolymers, thereby unambiguously demonstrating the influence of monomer distribution along the polymer chains on the micellization behavior. The internal structure of amphiphilic block and gradient co poly(2-oxazolines) based on the hydrophilic poly(2-methyl-2-oxazoline) (PMeOx) and the hydrophobic poly(2-phenyl-2-oxazoline) (PPhOx) was studied in water and water ethanol mixtures by small-angle X-ray scattering (SAXS), small angle neutron scattering (SANS), static and dynamic light scattering (SLS/DLS), and H-1 NMR spectroscopy. Contrast matching SANS experiments revealed that block copolymers form micelles with a uniform density profile of the core. In contrast to popular assumption, the outer part of the core of the gradient copolymer micelles has a distinctly higher density than the middle of the core. We attribute the latter finding to back-folding of chains resulting from hydrophilic hydrophobic interactions, leading to a new type of micelles that we refer to as micelles with a "bitterball-core" structure

    Real-Time Image Guided Ablative Prostate Cancer Radiation Therapy: Results From the TROG 15.01 SPARK Trial.

    Get PDF
    PurposeKilovoltage intrafraction monitoring (KIM) is a novel software platform implemented on standard radiation therapy systems and enabling real-time image guided radiation therapy (IGRT). In a multi-institutional prospective trial, we investigated whether real-time IGRT improved the accuracy of the dose patients with prostate cancer received during radiation therapy.Methods and materialsForty-eight patients with prostate cancer were treated with KIM-guided SABR with 36.25 Gy in 5 fractions. During KIM-guided treatment, the prostate motion was corrected for by either beam gating with couch shifts or multileaf collimator tracking. A dose reconstruction method was used to evaluate the dose delivered to the target and organs at risk with and without real-time IGRT. Primary outcome was the effect of real-time IGRT on dose distributions. Secondary outcomes included patient-reported outcomes and toxicity.ResultsMotion correction occurred in ≥1 treatment for 88% of patients (42 of 48) and 51% of treatments (121 of 235). With real-time IGRT, no treatments had prostate clinical target volume (CTV) D98% dose 5% less than planned. Without real-time IGRT, 13 treatments (5.5%) had prostate CTV D98% doses 5% less than planned. The prostate CTV D98% dose with real-time IGRT was closer to the plan by an average of 1.0% (range, -2.8% to 20.3%). Patient outcomes showed no change in the 12-month patient-reported outcomes compared with baseline and no grade ≥3 genitourinary or gastrointestinal toxicities.ConclusionsReal-time IGRT is clinically effective for prostate cancer SABR

    Induction of reactive oxygen intermediates in human monocytes by tumour cells and their role in spontaneous monocyte cytotoxicity

    Get PDF
    The present study examined the ability of human monocytes to produce reactive oxygen intermediates after a contact with tumour cells. Monocytes generated oxygen radicals, as measured by luminol-enhanced chemiluminescence and superoxide anion production, after stimulation with the tumour, but not with untransformed, cells. The use of specific oxygen radical scavengers and inhibitors, superoxide dismutase, catalase, dimethyl sulphoxide and deferoxamine as well as the myeloperoxidase inhibitor 4-aminobenzoic acid hydrazide, indicated that chemiluminescence was dependent on the production of superoxide anion and hydroxyl radical and the presence of myeloperoxidase. The tumour cell-induced chemiluminescent response of monocytes showed different kinetics from that seen after activation of monocytes with phorbol ester. These results indicate that human monocytes can be directly stimulated by tumour cells for reactive oxygen intermediate production. Spontaneous monocyte-mediated cytotoxicity towards cancer cells was inhibited by superoxide dismutase, catalase, deferoxamine and hydrazide, implicating the role of superoxide anion, hydrogen peroxide, hydroxyl radical and hypohalite. We wish to suggest that so-called ‘spontaneous’ tumoricidal capacity of freshly isolated human monocytes may in fact be an inducible event associated with generation of reactive oxygen intermediates and perhaps other toxic mediators, resulting from a contact of monocytes with tumour cells. © 1999 Cancer Research Campaig

    Comparison of the Safety and Pharmacokinetics of ST-246® after IV Infusion or Oral Administration in Mice, Rabbits and Monkeys

    Get PDF
    ST-246® is an antiviral, orally bioavailable small molecule in clinical development for treatment of orthopoxvirus infections. An intravenous (IV) formulation may be required for some hospitalized patients who are unable to take oral medication. An IV formulation has been evaluated in three species previously used in evaluation of both efficacy and toxicology of the oral formulation. plasma concentrations. These effects were eliminated using slower IV infusions. associated toxicity. Shorter infusions at higher doses in NHP resulted in decreased clearance, suggesting saturated distribution or elimination. Elimination half-lives in all species were similar between oral and IV administration. The administration of ST-246 was well tolerated as a slow IV infusion

    Safety of intravenous ferric carboxymaltose versus oral iron in patients with nondialysis-dependent CKD: an analysis of the 1-year FIND-CKD trial.

    Get PDF
    Background: The evidence base regarding the safety of intravenous (IV) iron therapy in patients with chronic kidney disease (CKD) is incomplete and largely based on small studies of relatively short duration. Methods: FIND-CKD (ClinicalTrials.gov number NCT00994318) was a 1-year, open-label, multicenter, prospective study of patients with nondialysis-dependent CKD, anemia and iron deficiency randomized (1:1:2) to IV ferric carboxymaltose (FCM), targeting higher (400-600 µg/L) or lower (100-200 µg/L) ferritin, or oral iron. A post hoc analysis of adverse event rates per 100 patient-years was performed to assess the safety of FCM versus oral iron over an extended period. Results: The safety population included 616 patients. The incidence of one or more adverse events was 91.0, 100.0 and 105.0 per 100 patient-years in the high ferritin FCM, low ferritin FCM and oral iron groups, respectively. The incidence of adverse events with a suspected relation to study drug was 15.9, 17.8 and 36.7 per 100 patient-years in the three groups; for serious adverse events, the incidence was 28.2, 27.9 and 24.3 per 100 patient-years. The incidence of cardiac disorders and infections was similar between groups. At least one ferritin level ≥800 µg/L occurred in 26.6% of high ferritin FCM patients, with no associated increase in adverse events. No patient with ferritin ≥800 µg/L discontinued the study drug due to adverse events. Estimated glomerular filtration rate remained the stable in all groups. Conclusions: These results further support the conclusion that correction of iron deficiency anemia with IV FCM is safe in patients with nondialysis-dependent CKD
    corecore