30 research outputs found

    Trends in the incidence of pulmonary nodules in chest computed tomography:10-year results from two Dutch hospitals

    Get PDF
    Objective: To study trends in the incidence of reported pulmonary nodules and stage I lung cancer in chest CT. Methods: We analyzed the trends in the incidence of detected pulmonary nodules and stage I lung cancer in chest CT scans in the period between 2008 and 2019. Imaging metadata and radiology reports from all chest CT studies were collected from two large Dutch hospitals. A natural language processing algorithm was developed to identify studies with any reported pulmonary nodule. Results: Between 2008 and 2019, a total of 74,803 patients underwent 166,688 chest CT examinations at both hospitals combined. During this period, the annual number of chest CT scans increased from 9955 scans in 6845 patients in 2008 to 20,476 scans in 13,286 patients in 2019. The proportion of patients in whom nodules (old or new) were reported increased from 38% (2595/6845) in 2008 to 50% (6654/13,286) in 2019. The proportion of patients in whom significant new nodules (≥ 5 mm) were reported increased from 9% (608/6954) in 2010 to 17% (1660/9883) in 2017. The number of patients with new nodules and corresponding stage I lung cancer diagnosis tripled and their proportion doubled, from 0.4% (26/6954) in 2010 to 0.8% (78/9883) in 2017. Conclusion: The identification of incidental pulmonary nodules in chest CT has steadily increased over the past decade and has been accompanied by more stage I lung cancer diagnoses. Clinical relevance statement: These findings stress the importance of identifying and efficiently managing incidental pulmonary nodules in routine clinical practice. Key Points: • The number of patients who underwent chest CT examinations substantially increased over the past decade, as did the number of patients in whom pulmonary nodules were identified. • The increased use of chest CT and more frequently identified pulmonary nodules were associated with more stage I lung cancer diagnoses.</p

    Role of Sox-9, ER81 and VE-Cadherin in Retinoic Acid-Mediated Trans-Differentiation of Breast Cancer Cells

    Get PDF
    Many aspects of development, tumor growth and metastasis depend upon the provision of an adequate vasculature. This can be a result of regulated angiogenesis, recruitment of circulating endothelial progenitors and/or vascular trans-differentiation. The present study demonstrates that treatment of SKBR-3 breast cancer cells with retinoic acid (RA), an important regulator of embryogenesis, cancer and other diseases, stimulates the formation of networks in Matrigel. RA-treatment of SKBR-3 cells co-cultured with human umbilical vein endothelial cells resulted in the formation of mixed structures. RA induces expression of many endothelial genes including vascular endothelial (VE) cadherin. VE-cadherin was also induced by RA in a number of other breast cancer cells. We show that RA-induced VE-cadherin is responsible for the RA-induced morphological changes. RA rapidly induced the expression of Sox-9 and ER81, which in turn form a complex on the VE-cadherin promoter and are required to mediate the transcriptional regulation of VE-cadherin by RA. These data indicate that RA may promote the expression of endothelial genes resulting in endothelial-like differentiation, or provide a mechanism whereby circulating endothelial progenitor cells could be incorporated into a growing organ or tumor

    Demand, supply, and restraint: Determinants of domestic water conflict and cooperation

    Get PDF
    This article focuses on one of the most likely empirical manifestations of the "environment-conflict" claim by examining how demand for and supply of water may lead to domestic water conflict. It also studies what factors may reduce the risk of conflict and, hence, induce cooperation. To this end, the article advances several theory-based arguments about the determinants of water conflict and cooperation, and then analyzes time-series cross-section data for 35 Mediterranean, Middle Eastern, and Sahel countries between 1997 and 2009. The empirical results show that demand-side drivers, such as population pressure, agricultural productivity, and economic development are likely to have a stronger impact on water conflict risk than supply-side factors, represented by climate variability. The analysis also reveals that violent water conflicts are extremely rare, and that factors conducive to restraint, such as stable political conditions, may stimulate cooperation. Overall, these results suggest that the joint analysis of demand, supply, and restraint improves our ability to account for domestic water-related conflict and cooperation

    Calibration of the CMS hadron calorimeters using proton-proton collision data at root s=13 TeV

    Get PDF
    Methods are presented for calibrating the hadron calorimeter system of theCMSetector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities vertical bar eta vertical bar ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.Peer reviewe

    Aid on Demand: African Leaders and the Geography of China's Foreign Assistance

    Full text link

    Musculoskeletal radiologist-level performance by using deep learning for detection of scaphoid fractures on conventional multi-view radiographs of hand and wrist.

    No full text
    OBJECTIVES: To assess how an artificial intelligence (AI) algorithm performs against five experienced musculoskeletal radiologists in diagnosing scaphoid fractures and whether it aids their diagnosis on conventional multi-view radiographs. METHODS: Four datasets of conventional hand, wrist, and scaphoid radiographs were retrospectively acquired at two hospitals (hospitals A and B). Dataset 1 (12,990 radiographs from 3353 patients, hospital A) and dataset 2 (1117 radiographs from 394 patients, hospital B) were used for training and testing a scaphoid localization and laterality classification component. Dataset 3 (4316 radiographs from 840 patients, hospital A) and dataset 4 (688 radiographs from 209 patients, hospital B) were used for training and testing the fracture detector. The algorithm was compared with the radiologists in an observer study. Evaluation metrics included sensitivity, specificity, positive predictive value (PPV), area under the characteristic operating curve (AUC), Cohen's kappa coefficient (κ), fracture localization precision, and reading time. RESULTS: The algorithm detected scaphoid fractures with a sensitivity of 72%, specificity of 93%, PPV of 81%, and AUC of 0.88. The AUC of the algorithm did not differ from each radiologist (0.87 [radiologists' mean], p ≥ .05). AI assistance improved five out of ten pairs of inter-observer Cohen's κ agreements (p < .05) and reduced reading time in four radiologists (p < .001), but did not improve other metrics in the majority of radiologists (p ≥ .05). CONCLUSIONS: The AI algorithm detects scaphoid fractures on conventional multi-view radiographs at the level of five experienced musculoskeletal radiologists and could significantly shorten their reading time. KEY POINTS: • An artificial intelligence algorithm automatically detects scaphoid fractures on conventional multi-view radiographs at the same level of five experienced musculoskeletal radiologists. • There is preliminary evidence that automated scaphoid fracture detection can significantly shorten the reading time of musculoskeletal radiologists

    Musculoskeletal radiologist-level performance by using deep learning for detection of scaphoid fractures on conventional multi-view radiographs of hand and wrist

    No full text
    Objectives: To assess how an artificial intelligence (AI) algorithm performs against five experienced musculoskeletal radiologists in diagnosing scaphoid fractures and whether it aids their diagnosis on conventional multi-view radiographs. Methods: Four datasets of conventional hand, wrist, and scaphoid radiographs were retrospectively acquired at two hospitals (hospitals A and B). Dataset 1 (12,990 radiographs from 3353 patients, hospital A) and dataset 2 (1117 radiographs from 394 patients, hospital B) were used for training and testing a scaphoid localization and laterality classification component. Dataset 3 (4316 radiographs from 840 patients, hospital A) and dataset 4 (688 radiographs from 209 patients, hospital B) were used for training and testing the fracture detector. The algorithm was compared with the radiologists in an observer study. Evaluation metrics included sensitivity, specificity, positive predictive value (PPV), area under the characteristic operating curve (AUC), Cohen’s kappa coefficient (κ), fracture localization precision, and reading time. Results: The algorithm detected scaphoid fractures with a sensitivity of 72%, specificity of 93%, PPV of 81%, and AUC of 0.88. The AUC of the algorithm did not differ from each radiologist (0.87 [radiologists’ mean], p ≥.05). AI assistance improved five out of ten pairs of inter-observer Cohen’s κ agreements (p <.05) and reduced reading time in four radiologists (p <.001), but did not improve other metrics in the majority of radiologists (p ≥.05). Conclusions: The AI algorithm detects scaphoid fractures on conventional multi-view radiographs at the level of five experienced musculoskeletal radiologists and could significantly shorten their reading time. Key Points: • An artificial intelligence algorithm automatically detects scaphoid fractures on conventional multi-view radiographs at the same level of five experienced musculoskeletal radiologists. • There is preliminary evidence that automated scaphoid fracture detection can significantly shorten the reading time of musculoskeletal radiologists

    Musculoskeletal radiologist-level performance by using deep learning for detection of scaphoid fractures on conventional multi-view radiographs of hand and wrist

    No full text
    Objectives: To assess how an artificial intelligence (AI) algorithm performs against five experienced musculoskeletal radiologists in diagnosing scaphoid fractures and whether it aids their diagnosis on conventional multi-view radiographs. Methods: Four datasets of conventional hand, wrist, and scaphoid radiographs were retrospectively acquired at two hospitals (hospitals A and B). Dataset 1 (12,990 radiographs from 3353 patients, hospital A) and dataset 2 (1117 radiographs from 394 patients, hospital B) were used for training and testing a scaphoid localization and laterality classification component. Dataset 3 (4316 radiographs from 840 patients, hospital A) and dataset 4 (688 radiographs from 209 patients, hospital B) were used for training and testing the fracture detector. The algorithm was compared with the radiologists in an observer study. Evaluation metrics included sensitivity, specificity, positive predictive value (PPV), area under the characteristic operating curve (AUC), Cohen’s kappa coefficient (κ), fracture localization precision, and reading time. Results: The algorithm detected scaphoid fractures with a sensitivity of 72%, specificity of 93%, PPV of 81%, and AUC of 0.88. The AUC of the algorithm did not differ from each radiologist (0.87 [radiologists’ mean], p ≥.05). AI assistance improved five out of ten pairs of inter-observer Cohen’s κ agreements (p <.05) and reduced reading time in four radiologists (p <.001), but did not improve other metrics in the majority of radiologists (p ≥.05). Conclusions: The AI algorithm detects scaphoid fractures on conventional multi-view radiographs at the level of five experienced musculoskeletal radiologists and could significantly shorten their reading time. Key Points: • An artificial intelligence algorithm automatically detects scaphoid fractures on conventional multi-view radiographs at the same level of five experienced musculoskeletal radiologists. • There is preliminary evidence that automated scaphoid fracture detection can significantly shorten the reading time of musculoskeletal radiologists
    corecore