284 research outputs found

    Efficacy and safety of 4 weeks' treatment with combined fluticasone furoate/vilanterol in a single inhaler given once daily in COPD: a placebo-controlled randomised trial

    Get PDF
    Background: Fluticasone furoate/vilanterol (FF/VI) is a novel once-daily (OD) inhaled corticosteroid/long-acting beta(2) agonist combination in development for chronic obstructive pulmonary disease (COPD) and asthma. Trial design: A multicentre, randomised, double-blind, parallel-group, placebo-controlled study. Methods: Participants were patients with moderate-to-severe COPD treated with placebo or FF/VI 400/25 mu g OD for 4 weeks. Study objectives were to assess the safety and efficacy of FF/VI 400/25 mg OD administered for 4 weeks via a novel dry powder inhaler. Co-primary end points were change from baseline in weighted mean (wm) heart rate 0-4 h postdose at day 28 and the incidence of adverse events (AEs). Secondary end points included change from baseline in trough forced expiratory volume in one second (FEV1) (23-24 h postdose; day 29) and wm FEV1 (0-4 h postdose; day 28). Patients were randomised to receive FF/VI 400/25 mg or placebo in a 2: 1 ratio; all patients and investigators were blinded to active or placebo treatment. Results: 60 patients (mean age 64 years) were randomised (FF/VI: n=40; placebo: n=20), and all contributed data to the analysis. Mean screening post-bronchodilator FEV1 per cent predicted was comparable between groups (FF/VI: 58.5%; placebo: 60.1%). The wm heart rate 0-4 h postdose was similar between groups (difference: 0.6 beats per minute; 95% CI -3.9 to 5.1). More on-treatment AEs were reported in the FF/VI group (68%) compared with the placebo group (50%). The most common drug-related AEs in the FF/VI group were oral candidiasis (8%) and dysphonia (5%). There were no clinically relevant effects on laboratory values, including glucose and potassium, or on vital signs or ECGs/Holters. The FF/VI group had statistically greater improvements compared with placebo in trough FEV1 (mean difference 183 ml) and 0-4 h postdose wm FEV1 (mean difference 236 ml). Conclusion: FF/VI has a good safety and tolerability profile and improves lung function compared with placebo in patients with COPD. Trial registration number: clinical trials. gov-NCT00731822

    Efficacy and safety of 4 weeks' treatment with combined fluticasone furoate/vilanterol in a single inhaler given once daily in COPD: a placebo-controlled randomised trial

    Get PDF
    Background. Fluticasone furoate/vilanterol (FF/VI) is a novel once-daily (OD) inhaled corticosteroid/long-acting β2 agonist combination in development for chronic obstructive pulmonary disease (COPD) and asthma. Trial design. A multicentre, randomised, double-blind, parallel-group, placebo-controlled study. Methods. Participants were patients with moderate-to-severe COPD treated with placebo or FF/VI 400/25 μg OD for 4 weeks. Study objectives were to assess the safety and efficacy of FF/VI 400/25 μg OD administered for 4 weeks via a novel dry powder inhaler. Co-primary end points were change from baseline in weighted mean (wm) heart rate 0–4 h postdose at day 28 and the incidence of adverse events (AEs). Secondary end points included change from baseline in trough forced expiratory volume in one second (FEV1) (23–24 h postdose; day 29) and wm FEV1 (0–4 h postdose; day 28). Patients were randomised to receive FF/VI 400/25 μg or placebo in a 2:1 ratio; all patients and investigators were blinded to active or placebo treatment. Results. 60 patients (mean age 64 years) were randomised (FF/VI: n=40; placebo: n=20), and all contributed data to the analysis. Mean screening post-bronchodilator FEV1 per cent predicted was comparable between groups (FF/VI: 58.5%; placebo: 60.1%). The wm heart rate 0–4 h postdose was similar between groups (difference: 0.6 beats per minute; 95% CI −3.9 to 5.1). More on-treatment AEs were reported in the FF/VI group (68%) compared with the placebo group (50%). The most common drug-related AEs in the FF/VI group were oral candidiasis (8%) and dysphonia (5%). There were no clinically relevant effects on laboratory values, including glucose and potassium, or on vital signs or ECGs/Holters. The FF/VI group had statistically greater improvements compared with placebo in trough FEV1 (mean difference 183 ml) and 0–4 h postdose wm FEV1 (mean difference 236 ml). Conclusion. FF/VI has a good safety and tolerability profile and improves lung function compared with placebo in patients with COPD.publishedVersio

    Evaluation of an ambulatory system for the quantification of cough frequency in patients with chronic obstructive pulmonary disease

    Get PDF
    BACKGROUND: To date, methods used to assess cough have been primarily subjective, and only broadly reflect the impact of chronic cough and/or chronic cough therapies on quality of life. Objective assessment of cough has been attempted, but early techniques were neither ambulatory nor feasible for long-term data collection. We evaluated a novel ambulatory cardio-respiratory monitoring system with an integrated unidirectional, contact microphone, and report here the results from a study of patients with COPD who were videotaped in a quasi-controlled environment for 24 continuous hours while wearing the ambulatory system. METHODS: Eight patients with a documented history of COPD with ten or more years of smoking (6 women; age 57.4 ± 11.8 yrs.; percent predicted FEV(1 )49.6 ± 13.7%) who complained of cough were evaluated in a clinical research unit equipped with video and sound recording capabilities. All patients wore the LifeShirt(® )system (LS) while undergoing simultaneous video (with sound) surveillance. Video data were visually inspected and annotated to indicate all cough events. Raw physiologic data records were visually inspected by technicians who remained blinded to the video data. Cough events from LS were analyzed quantitatively with a specialized software algorithm to identify cough. The output of the software algorithm was compared to video records on a per event basis in order to determine the validity of the LS system to detect cough in COPD patients. RESULTS: Video surveillance identified a total of 3,645 coughs, while LS identified 3,363 coughs during the same period. The median cough rate per patient was 21.3 coughs·hr(-1 )(Range: 10.1 cghs·hr(-1 )– 59.9 cghs·hr(-1)). The overall accuracy of the LS system was 99.0%. Overall sensitivity and specificity of LS, when compared to video surveillance, were 0.781 and 0.996, respectively, while positive- and negative-predictive values were 0.846 and 0.994. There was very good agreement between the LS system and video (kappa = 0.807). CONCLUSION: The LS system demonstrated a high level of accuracy and agreement when compared to video surveillance for the measurement of cough in patients with COPD

    Electron Transfer from Cyt b559 and Tyrosine-D to the S2 and S3 states of the water oxidizing complex in Photosystem II at Cryogenic Temperatures

    Get PDF
    The Mn4CaO5 cluster of photosystem II (PSII) catalyzes the oxidation of water to molecular oxygen through the light-driven redox S-cycle. The water oxidizing complex (WOC) forms a triad with Tyrosine(Z) and P-680, which mediates electrons from water towards the acceptor side of PSII. Under certain conditions two other redox-active components, Tyrosine(D) (Y-D) and Cytochrome b (559) (Cyt b (559)) can also interact with the S-states. In the present work we investigate the electron transfer from Cyt b (559) and Y-D to the S-2 and S-3 states at 195 K. First, Y-D (aEuro cent) and Cyt b (559) were chemically reduced. The S-2 and S-3 states were then achieved by application of one or two laser flashes, respectively, on samples stabilized in the S-1 state. EPR signals of the WOC (the S-2-state multiline signal, ML-S-2), Y-D (aEuro cent) and oxidized Cyt b (559) were simultaneously detected during a prolonged dark incubation at 195 K. During 163 days of incubation a large fraction of the S-2 population decayed to S-1 in the S-2 samples by following a single exponential decay. Differently, S-3 samples showed an initial increase in the ML-S-2 intensity (due to S-3 to S-2 conversion) and a subsequent slow decay due to S-2 to S-1 conversion. In both cases, only a minor oxidation of Y-D was observed. In contrast, the signal intensity of the oxidized Cyt b (559) showed a two-fold increase in both the S-2 and S-3 samples. The electron donation from Cyt b (559) was much more efficient to the S-2 state than to the S-3 state

    Spektroskopische Eigenschaften eines biologisch‐relevanten [Fe2(μ‐O)2] Diamond‐Core‐Motivs mit einem kurzen Eisen‐Eisen‐Abstand

    Get PDF
    Dieisen-Kofaktoren in Enzymen vollziehen diverse anspruchsvolle Transformationen. Die Strukturen hoch-valenter Intermediate (Q in der löslichen Methanmonooxygenase und X in der Ribonukleotidreduktase) sind Gegenstand aktueller Diskussionen, seit Fe-Fe-Abstände von 2.1–3.4 Å eine Zuordnung zu geöffneten und geschlossen Kernen mit verbrückenden oder terminalen Oxido-Gruppen in den aktiven Zentren ermöglichen. In dieser Studie berichten wir die kristallografische und spektroskopische Charakterisierung eines FeIII2(μ-O)2-Komplexes (2) mit tetraedrischen (4C) Zentren sowie einem geringen Fe-Fe-Abstand (2.52 Å), der in Lösungsmitteln beständig ist. 2 zeigt eine große Fe-K-Vorkanten-Intensität. Diese resultiert aus der starken Asymmetrie an den TD-FeIII-Zentren bedingt durch die kurzen Fe-μ-O-Bindungen. Während ein Fe-Fe-Abstand von ≈2.5 Å für sechsfach-koordinierte Zentren in Q und X unwahrscheinlich ist, könnte ein Fe2(μ-O)2-Kern mit vierfacher (oder möglicherweise auch fünffacher) Koordination flexibel genug sein, um eine kurze Fe-Fe-Separierung mit großer Vorkanten-Intensität zu ermöglichen. Diese Erkenntnis kann dazu beitragen, dass weitere Modelle für die Strukturen der hoch-valenten Dieisen-Intermediate, die sich im Zuge der biologischen O2-Aktivierung bilden, in Betracht gezogen werden

    Chrysomelidial in the Opisthonotal Glands of the Oribatid Mite, Oribotritia berlesei

    Get PDF
    Gas chromatographic–mass spectrometric analyses of whole body extracts of Oribotritia berlesei, a large-sized soil-dwelling oribatid mite, revealed a consistent chemical pattern of ten components, probably originating from the well-developed opisthonotal glands. The three major components of the extract were the iridoid monoterpene, (3S,8S)-chrysomelidial (about 45% of the extract), the unsaturated hydrocarbon 6,9-heptadecadiene, and the diterpene β-springene (the latter two, each about 20–25% of the extract). The remaining minor components (together about 10% of the extract) included a series of hydrocarbons (tridecene, tridecane, pentadecene, pentadecane, 8-heptadecene, and heptadecane) and the tentatively identified 9,17-octadecadienal. In contrast, analysis of juveniles showed only two compounds, namely a 2:1 mixture of (3S,8S)-chrysomelidial and its epimer, epi-chrysomelidial (3S,8R-chrysomelidial). Unexpectedly, neither adult nor juvenile secretions contained the so-called astigmatid compounds, which are considered characteristic of secretions of oribatids above moderately derived Mixonomata. The chrysomelidials, as well as β-springene and octadecadienal, are newly identified compounds in the opisthonotal glands of oribatid mites and have chemotaxonomic potential for this group. This is the first instance of finding chrysomelidials outside the Coleoptera

    Is Mn-Bound Substrate Water Protonated in the S2 State of Photosystem II?

    Get PDF
    In spite of great progress in resolving the geometric structure of the water-splitting Mn4OxCa cluster in photosystem II, the binding sites and modes of the two substrate water molecules are still insufficiently characterized. While time-resolved membrane-inlet mass spectrometry measurements indicate that both substrate water molecules are bound to the oxygen-evolving complex (OEC) in the S2 and S3 states (Hendry and Wydrzynski in Biochemistry 41:13328–13334, 2002), it is not known (1) if they are both Mn-bound, (2) if they are terminal or bridging ligands, and (3) in what protonation state they are bound in the different oxidation states Si (i = 0, 1, 2, 3, 4) of the OEC. By employing 17O hyperfine sublevel correlation (HYSCORE) spectroscopy we recently demonstrated that in the S2 state there is only one (type of) Mn-bound oxygen that is water exchangeable. We therefore tentatively identified this oxygen as one substrate ‘water’ molecule, and on the basis of the finding that it has a hyperfine interaction of about 10 MHz with the electron spin of the Mn4OxCa cluster, we suggest that it is bound as a Mn–O–Mn bridge within a bis-μ2 oxo-bridged unit (Su et al. in J Am Chem Soc 130:786–787, 2008). Employing pulse electron paramagnetic resonance, 1H/2H Mims electron-nuclear double resonance and 2H-HYSCORE spectroscopies together with 1H/2H-exchange here, we test this hypothesis by probing the protonation state of this exchangeable oxygen. We conclude that this oxygen is fully deprotonated. This result is discussed in the light of earlier reports in the literature

    Guiding principles for the development and application of solid-phase phosphorus adsorbents for freshwater ecosystems

    Get PDF
    While a diverse array of phosphorus (P)-adsorbent materials is currently available for application to freshwater aquatic systems, selection of the most appropriate P-adsorbents remains problematic. In particular, there has to be a close correspondence between attributes of the P-adsorbent, its field performance, and the management goals for treatment. These management goals may vary from a rapid reduction in dissolved P to address seasonal enrichments from internal loading, targeting external fluxes due to anthropogenic sources, or long term inactivation of internal P inventories contained within bottom sediments. It also remains a challenge to develop new methods and materials that are ecologically benign and cost-effective. We draw on evidence in the literature and the authors’ personal experiences in the field, to summarise the attributes of a range of P-adsorbent materials. We offer 'guiding principles' to support practical use of existing materials and outline key development needs for new materials
    corecore