1,192 research outputs found

    Deep LOFAR observations of the merging galaxy cluster CIZA J2242.8+5301

    Get PDF
    Previous studies have shown that CIZA J2242.8+5301 (the 'Sausage' cluster, z = 0.192) is a massive merging galaxy cluster that hosts a radio halo and multiple relics. In this paper, we present deep, high-fidelity, low-frequency images made with the LOw-Frequency Array (LOFAR) between 115.5 and 179 MHz. These images, with a noise of 140 μJy beam- 1 and a resolution of θbeam = 7.3 arcsec × 5.3 arcsec, are an order of magnitude more sensitive and five times higher resolution than previous low-frequency images of this cluster. We combined the LOFAR data with the existing Giant Metrewave Radio Telescope (GMRT) (153, 323, 608 MHz) and Westerbork Synthesis Radio Telescope (WSRT) (1.2, 1.4, 1.7, 2.3 GHz) data to study the spectral properties of the radio emission from the cluster. Assuming diffusive shock acceleration (DSA), we found Mach numbers of Mn=2.7{}_{-0.3}^{+0.6} and Ms=1.9_{-0.2}^{+0.3} for the northern and southern shocks. The derived Mach number for the northern shock requires an acceleration efficiency of several percent to accelerate electrons from the thermal pool, which is challenging for DSA. Using the radio data, we characterized the eastern relic as a shock wave propagating outwards with a Mach number of Me=2.4_{-0.3}^{+0.5}, which is in agreement with MeX=2.5{}_{-0.2}^{+0.6} that we derived from Suzaku data. The eastern shock is likely to be associated with the major cluster merger. The radio halo was measured with a flux of 346 ± 64 mJy at 145 MHz. Across the halo, we observed a spectral index that remains approximately constant (α ^{145 MHz-2.3 GHz}_{{across ˜ 1 Mpc}^2}=-1.01± 0.10) after the steepening in the post-shock region of the northern relic. This suggests a generation of post-shock turbulence that re-energies aged electrons

    The nature of the low-frequency emission of M51: First observations of a nearby galaxy with LOFAR

    Get PDF
    The grand-design spiral galaxy M51 was observed with the LOFAR High Frequency Antennas (HBA) and imaged in total intensity and polarisation. This observation covered the frequencies between 115 MHz and 175 MHz. We produced an image of total emission of M51 at the mean frequency of 151 MHz with 20 arcsec resolution and 0.3 mJy rms noise, which is the most sensitive image of a galaxy at frequencies below 300 MHz so far. The integrated spectrum of total radio emission is described well by a power law, while flat spectral indices in the central region indicate thermal absorption. We observe that the disk extends out to 16 kpc and see a break in the radial profile near the optical radius of the disk. Our main results, the scale lengths of the inner and outer disks at 151 MHz and 1.4 GHz, arm--interarm contrast, and the break scales of the radio--far-infrared correlations, can be explained consistently by CRE diffusion, leading to a longer propagation length of CRE of lower energy. The distribution of CRE sources drops sharply at about 10 kpc radius, where the star formation rate also decreases sharply. We find evidence that thermal absorption is primarily caused by HII regions. The non-detection of polarisation from M51 at 151 MHz is consistent with the estimates of Faraday depolarisation. Future searches for polarised emission in this frequency range should concentrate on regions with low star formation rates.Comment: 20 pages, 18 figures, accepted for publication in A&

    LOFAR MSSS: The Scaling Relation between AGN Cavity Power and Radio Luminosity at Low Radio Frequencies

    Get PDF
    This article has been accepted for publication in a forthcoming issue of Astronomy & Astrophysics. Reproduced with permission from Astronomy & Astrophysics. © 2018 ESO.We present a new analysis of the widely used relation between cavity power and radio luminosity in clusters of galaxies with evidence for strong AGN feedback. We study the correlation at low radio frequencies using two new surveys - the First Alternative Data Release of the TIFR GMRT Sky Survey (TGSS ADR1) at 148 MHz and LOFAR's first all-sky survey, the Multifrequency Snapshot Sky Survey (MSSS) at 140 MHz. We find a scaling relation PcavL148βP_{\rm cav} \propto L_{148}^{\beta}, with a logarithmic slope of β=0.51±0.14\beta = 0.51 \pm 0.14, which is in good agreement with previous results based on data at 327 MHz. The large scatter present in this correlation confirms the conclusion reached at higher frequencies that the total radio luminosity at a single frequency is a poor predictor of the total jet power. We show that including measurements at 148 MHz alone is insufficient to reliably compute the bolometric radio luminosity and reduce the scatter in the correlation. For a subset of four well-resolved sources, we examine the detected extended structures at low frequencies and compare with the morphology known from higher frequency images and Chandra X-ray maps. In Perseus we discuss details in the structures of the radio mini-halo, while in the 2A 0335+096 cluster we observe new diffuse emission associated with multiple X-ray cavities and likely originating from past activity. For A2199 and MS 0735.6+7421, we confirm that the observed low-frequency radio lobes are confined to the extents known from higher frequencies. This new low-frequency analysis highlights the fact that existing cavity power to radio luminosity relations are based on a relatively narrow range of AGN outburst ages. We discuss how the correlation could be extended using low frequency data from the LOFAR Two-metre Sky Survey (LoTSS) in combination with future, complementary deeper X-ray observations.Peer reviewe

    Polarized point sources in the LOFAR Two-meter Sky Survey: A preliminary catalog

    Get PDF
    The polarization properties of radio sources at very low frequencies (h45m–15h30m right ascension, 45°–57° declination, 570 square degrees). We have produced a catalog of 92 polarized radio sources at 150 MHz at 4.′3 resolution and 1 mJy rms sensitivity, which is the largest catalog of polarized sources at such low frequencies. We estimate a lower limit to the polarized source surface density at 150 MHz, with our resolution and sensitivity, of 1 source per 6.2 square degrees. We find that our Faraday depth measurements are in agreement with previous measurements and have significantly smaller errors. Most of our sources show significant depolarization compared to 1.4 GHz, but there is a small population of sources with low depolarization indicating that their polarized emission is highly localized in Faraday depth. We predict that an extension of this work to the full LOTSS data would detect at least 3400 polarized sources using the same methods, and probably considerably more with improved data processing

    Molecular Typing of Mycobacterium tuberculosis Strains with a Common Two-Band IS6110 Pattern

    Get PDF
    We conducted a population-based molecular typing of all Mycobacterium tuberculosis isolates obtained in Alabama since 1994. Of 2,452 isolates, 1,013 (41%) had fewer than 6 bands of IS6110; 348 (14%) had a single two-band pattern (JH2). With conventional epidemiologic methods, we identified three groups of related patients with JH2 isolates. Spoligotyping and pattern of variable number of tandem repeats identified 10 molecular groups; two found by conventional methods were subdivided

    LOFAR Sparse Image Reconstruction

    Get PDF
    Context. The LOw Frequency ARray (LOFAR) radio telescope is a giant digital phased array interferometer with multiple antennas distributed in Europe. It provides discrete sets of Fourier components of the sky brightness. Recovering the original brightness distribution with aperture synthesis forms an inverse problem that can be solved by various deconvolution and minimization methods Aims. Recent papers have established a clear link between the discrete nature of radio interferometry measurement and the "compressed sensing" (CS) theory, which supports sparse reconstruction methods to form an image from the measured visibilities. Empowered by proximal theory, CS offers a sound framework for efficient global minimization and sparse data representation using fast algorithms. Combined with instrumental direction-dependent effects (DDE) in the scope of a real instrument, we developed and validated a new method based on this framework Methods. We implemented a sparse reconstruction method in the standard LOFAR imaging tool and compared the photometric and resolution performance of this new imager with that of CLEAN-based methods (CLEAN and MS-CLEAN) with simulated and real LOFAR data Results. We show that i) sparse reconstruction performs as well as CLEAN in recovering the flux of point sources; ii) performs much better on extended objects (the root mean square error is reduced by a factor of up to 10); and iii) provides a solution with an effective angular resolution 2-3 times better than the CLEAN images. Conclusions. Sparse recovery gives a correct photometry on high dynamic and wide-field images and improved realistic structures of extended sources (of simulated and real LOFAR datasets). This sparse reconstruction method is compatible with modern interferometric imagers that handle DDE corrections (A- and W-projections) required for current and future instruments such as LOFAR and SKAComment: Published in A&A, 19 pages, 9 figure

    Perceptions and experiences of healthcare workers during the COVID-19 pandemic in the UK

    Get PDF
    OBJECTIVE: The COVID-19 pandemic has set unprecedented demand on the healthcare workforce around the world. The UK has been one of the most affected countries in Europe. The aim of this study was to explore the perceptions and experiences of healthcare workers (HCWs) in relation to COVID-19 and care delivery models implemented to deal with the pandemic in the UK. METHODS: The study was designed as a rapid appraisal combining: (1) a review of UK healthcare policies (n=35 policies), (2) mass media and social media analysis of front-line staff experiences and perceptions (n=101 newspaper articles, n=1 46 000 posts) and (3) in-depth (telephone) interviews with front-line staff (n=30 interviews). The findings from all streams were analysed using framework analysis. RESULTS: Limited personal protective equipment (PPE) and lack of routine testing created anxiety and distress and had a tangible impact on the workforce. When PPE was available, incorrect size and overheating complicated routine work. Lack of training for redeployed staff and the failure to consider the skills of redeployed staff for new areas were identified as problems. Positive aspects of daily work reported by HCWs included solidarity between colleagues, the establishment of well-being support structures and feeling valued by society. CONCLUSION: Our study highlighted the importance of taking into consideration the experiences and concerns of front-line staff during a pandemic. Staff working in the UK during the COVID-19 pandemic advocated clear and consistent guidelines, streamlined testing of HCWs, administration of PPE and acknowledgement of the effects of PPE on routine practice

    Comparison of immunohistochemistry with immunoassay (ELISA) for the detection of components of the plasminogen activation system in human tumour tissue

    Get PDF
    Enzyme-linked immunosorbent assay (ELISA) methods and immunohistochemistry (IHC) are techniques that provide information on protein expression in tissue samples. Both methods have been used to investigate the impact of the plasminogen activation (PA) system in cancer. In the present paper we first compared the expression levels of uPA, tPA, PAI-1 and uPAR in a compound group consisting of 33 cancer lesions of various origin (breast, lung, colon, cervix and melanoma) as quantitated by ELISA and semi-quantitated by IHC. Secondly, the same kind of comparison was performed on a group of 23 melanoma lesions and a group of 28 breast carcinoma lesions. The two techniques were applied to adjacent parts of the same frozen tissue sample, enabling the comparison of results obtained on material of almost identical composition. Spearman correlation coefficients between IHC results and ELISA results for uPA, tPA, PAI-1 and uPAR varied between 0.41 and 0.78, and were higher for the compound group and the breast cancer group than for the melanoma group. Although a higher IHC score category was always associated with an increased median ELISA value, there was an overlap of ELISA values from different scoring classes. Hence, for the individual tumour cases the relation between ELISA and IHC is ambiguous. This indicates that the two techniques are not directly interchangeable and that their value for clinical purposes may be different. © 1999 Cancer Research Campaig

    Perceptions and experiences of healthcare workers during the COVID-19 pandemic in the UK

    Get PDF
    Objective The COVID-19 pandemic has set unprecedented demand on the healthcare workforce around the world. The UK has been one of the most affected countries in Europe. The aim of this study was to explore the perceptions and experiences of healthcare workers (HCWs) in relation to COVID-19 and care delivery models implemented to deal with the pandemic in the UK. Methods The study was designed as a rapid appraisal combining: (1) a review of UK healthcare policies (n=35 policies), (2) mass media and social media analysis of front-line staff experiences and perceptions (n=101 newspaper articles, n=1 46 000 posts) and (3) in-depth (telephone) interviews with front-line staff (n=30 interviews). The findings from all streams were analysed using framework analysis. Results Limited personal protective equipment (PPE) and lack of routine testing created anxiety and distress and had a tangible impact on the workforce. When PPE was available, incorrect size and overheating complicated routine work. Lack of training for redeployed staff and the failure to consider the skills of redeployed staff for new areas were identified as problems. Positive aspects of daily work reported by HCWs included solidarity between colleagues, the establishment of well-being support structures and feeling valued by society. Conclusion Our study highlighted the importance of taking into consideration the experiences and concerns of front-line staff during a pandemic. Staff working in the UK during the COVID-19 pandemic advocated clear and consistent guidelines, streamlined testing of HCWs, administration of PPE and acknowledgement of the effects of PPE on routine practice
    corecore