1,161 research outputs found

    Hands-free, precision control for small hovering vehicles - A flying qualities study Final report

    Get PDF
    Flight simulator determination of human balancing reflex for control of small hovering vehicle

    Fermi Large Area Telescope Fourth Source Catalog Data Release 4 (4FGL-DR4)

    Full text link
    We present an incremental version (4FGL-DR4, for Data Release 4) of the fourth Fermi-LAT catalog of gamma-ray sources. Based on the first 14 years of science data in the energy range from 50 MeV to 1 TeV, it uses the same analysis methods as the 4FGL-DR3 catalog did for 12 years of data, with only a few improvements. The spectral parameters, spectral energy distributions, light curves and associations are updated for all sources. We add four new extended sources and modify two existing ones. Among the 6658 4FGL-DR3 sources, we delete 14 and change the localization of 10, while 26 are newly associated and two associations were changed. We add 546 point sources, among which 8 are considered identified and 228 have a plausible counterpart at other wavelengths. Most are just above the detection threshold, and 14 are transient sources below the detection threshold that can affect the light curves of nearby sources.Comment: Data files at https://fermi.gsfc.nasa.gov/ssc/data/access/lat/14yr_catalog/. Refereed paper is DOI 10.3847/1538-4365/ac675

    Is the black-widow pulsar PSR J1555-2908 in a hierarchical triple system?

    Get PDF
    The 559 Hz black-widow pulsar PSR J1555-2908, originally discovered in radio, is also a bright gamma-ray pulsar. Timing its pulsations using 12 yr of Fermi-LAT gamma-ray data reveals long-term variations in its spin frequency that are much larger than is observed from other millisecond pulsars. While this variability in the pulsar rotation rate could be intrinsic "timing noise", here we consider an alternative explanation: the variations arise from the presence of a very-low-mass third object in a wide multi-year orbit around the neutron star and its low-mass companion. With current data, this hierarchical-triple-system model describes the pulsar's rotation slightly more accurately than the best-fitting timing-noise model. Future observations will show if this alternative explanation is correct

    Measurement of 1.7 to 74 MeV polarised gamma rays with the HARPO TPC

    Full text link
    Current {\gamma}-ray telescopes based on photon conversions to electron-positron pairs, such as Fermi, use tungsten converters. They suffer of limited angular resolution at low energies, and their sensitivity drops below 1 GeV. The low multiple scattering in a gaseous detector gives access to higher angular resolution in the MeV-GeV range, and to the linear polarisation of the photons through the azimuthal angle of the electron-positron pair. HARPO is an R&D program to characterise the operation of a TPC (Time Projection Chamber) as a high angular-resolution and sensitivity telescope and polarimeter for {\gamma} rays from cosmic sources. It represents a first step towards a future space instrument. A 30 cm cubic TPC demonstrator was built, and filled with 2 bar argon-based gas. It was put in a polarised {\gamma}-ray beam at the NewSUBARU accelerator in Japan in November 2014. Data were taken at different photon energies from 1.7 MeV to 74 MeV, and with different polarisation configurations. The electronics setup is described, with an emphasis on the trigger system. The event reconstruction algorithm is quickly described, and preliminary measurements of the polarisation of 11 MeVphotons are shown.Comment: Proceedings VCI201

    Mrk 421, Mrk 501, and 1ES 1426+428 at 100 GeV with the CELESTE Cherenkov Telescope

    Get PDF
    We have measured the gamma-ray fluxes of the blazars Mrk 421 and Mrk 501 in the energy range between 50 and 350 GeV (1.2 to 8.3 x 10^25 Hz). The detector, called CELESTE, used first 40, then 53 heliostats of the former solar facility "Themis" in the French Pyrenees to collect Cherenkov light generated in atmospheric particle cascades. The signal from Mrk 421 is often strong. We compare its flux with previously published multi-wavelength studies and infer that we are straddling the high energy peak of the spectral energy distribution. The signal from Mrk 501 in 2000 was weak (3.4 sigma). We obtain an upper limit on the flux from 1ES 1426+428 of less than half that of the Crab flux near 100 GeV. The data analysis and understanding of systematic biases have improved compared to previous work, increasing the detector's sensitivity.Comment: 15 pages, 14 figures, accepted to A&A (July 2006) August 19 -- corrected error in author lis

    Alteration of the in vivo nicotinic receptor density in ADNFLE patients: a PET study

    Get PDF
    Nicotinic acetylcholine receptors (nAChRs) are involved in a familial form of frontal lobe epilepsy, autosomal dominant nocturnal frontal lobe epilepsy (ADNFLE). In several ADNFLE families, mutations were identified in the nAChR α4 or β2 subunit, which together compose the main cerebral nAChR. Electrophysiological assessment using in vitro expression systems indicated a gain of function of the mutant receptors. However the precise mechanisms by which they contribute to the pathogenesis of a focal epilepsy remain obscure, especially since α4β2 nAChRs are known to be widely distributed within the entire brain. PET study using [18F]-F-A-85380, a high affinity agonist at the α4β2 nAChRs, allows the determination of the regional distribution and density of the nAChRs in healthy volunteers and in ADNFLE patients, thus offering a unique opportunity to investigate some in vivo consequences of the molecular defect. We have assessed nAChR distribution in eight non-smoking ADNFLE patients (from five families) bearing an identified mutation in nAChRs and in seven age-matched non-smoking healthy volunteers using PET and [18F]-F-A-85380. Parametric images of volume of distribution (Vd) were generated as the ratio of tissue to plasma radioactivities. The images showed a clear difference in the pattern of the nAChR density in the brains of the patients compared to the healthy volunteers. Vd values revealed a significant increase (between 12 and 21%, P < 0.05) in the ADNFLE patients in the mesencephalon, the pons and the cerebellum when compared to control subjects. Statistical parametric mapping (SPM) was then used to better analyse subtle regional differences. This analysis confirmed clear regional differences between patients and controls: patients had increased nAChR density in the epithalamus, ventral mesencephalon and cerebellum, but decreased nAChR density in the right dorsolateral prefrontal region. In five patients who underwent an additional [18F]-fluorodeoxyglucose (FDG) PET experiment, hypometabolism was observed in the neighbouring area of the right orbitofrontal cortex. The demonstration of a regional nAChR density decrease in the prefrontal cortex, despite the known distribution of these receptors throughout the cerebral cortex, is consistent with a focal epilepsy involving the frontal lobe. We also propose that the nAChR density increase in mesencephalon is involved in the pathophysiology of ADNFLE through the role of brainstem ascending cholinergic systems in arousa

    Advanced Silicon-on-Insulator: Crystalline Silicon on Atomic Layer Deposited Beryllium Oxide

    Get PDF
    Silicon-on-insulator (SOI) technology improves the performance of devices by reducing parasitic capacitance. Devices based on SOI or silicon-on-sapphire technology are primarily used in high-performance radio frequency (RF) and radiation sensitive applications as well as for reducing the short channel effects in microelectronic devices. Despite their advantages, the high substrate cost and overheating problems associated with complexities in substrate fabrication as well as the low thermal conductivity of silicon oxide prevent broad applications of this technology. To overcome these challenges, we describe a new approach of using beryllium oxide (BeO). The use of atomic layer deposition (ALD) for producing this material results in lowering the SOI wafer production cost. Furthermore, the use of BeO exhibiting a high thermal conductivity might minimize the self-heating issues. We show that crystalline Si can be grown on ALD BeO and the resultant devices exhibit potential for use in advanced SOI technology applications

    GPs' reasons for referral of patients with chest pain: a qualitative study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Prompt diagnosis of an acute coronary syndrome is very important and urgent referral to a hospital is imperative because fast treatment can be life-saving and increase the patient's life expectancy and quality of life. The aim of our study was to identify GPs' reasons for referring or not referring patients presenting with chest pain.</p> <p>Methods</p> <p>In a semi-structured interview, 21 GPs were asked to describe why they do or do not refer a patient presenting with chest pain. Interviews were taped, transcribed and qualitatively analysed.</p> <p>Results</p> <p>Histories of 21 patients were studied. Six were not referred, seven were referred to a cardiologist and eight to the emergency department. GPs' reasons for referral were background knowledge about the patient, patient's age and cost-benefit estimation, the perception of a negative attitude from the medical rescue team, recent patient contact with a cardiologist without detection of a coronary disease and the actual presentation of signs and symptoms, gut feeling, clinical examination and ECG results.</p> <p>Conclusion</p> <p>This study suggests that GPs believe they do not exclusively use the 'classical' signs and symptoms in their decision-making process for patients presenting with chest pain. Background knowledge about the patient, GPs' personal ideas and gut feeling are also important.</p

    Discovery, Timing, and Multiwavelength Observations of the Black Widow Millisecond Pulsar PSR J1555-2908

    Get PDF
    We report the discovery of PSR J1555-2908, a 1.79 ms radio and gamma-ray pulsar in a 5.6 hr binary system with a minimum companion mass of 0.052 MM_\odot. This fast and energetic (E˙=3×1035\dot E = 3 \times 10^{35} erg/s) millisecond pulsar was first detected as a gamma-ray point source in Fermi LAT sky survey observations. Guided by a steep spectrum radio point source in the Fermi error region, we performed a search at 820 MHz with the Green Bank Telescope that first discovered the pulsations. The initial radio pulse timing observations provided enough information to seed a search for gamma-ray pulsations in the LAT data, from which we derive a timing solution valid for the full Fermi mission. In addition to the radio and gamma-ray pulsation discovery and timing, we searched for X-ray pulsations using NICER but no significant pulsations were detected. We also obtained time-series r-band photometry that indicates strong heating of the companion star by the pulsar wind. Material blown off the heated companion eclipses the 820 MHz radio pulse during inferior conjunction of the companion for ~10% of the orbit, which is twice the angle subtended by its Roche lobe in an edge-on system
    corecore