26 research outputs found

    Population-based study of multiplexed IgE sensitization in relation to asthma, exhaled nitric oxide, and bronchial responsiveness.

    No full text
    To access publisher's full text version of this article. Please click on the hyperlink in Additional Links field.IgE sensitization is an important risk factor for the development of asthma. The aim of this study was to investigate the IgE antibody profile for a broad spectrum of allergen molecules in asthmatic patients. Participants from the European Community Respiratory Health Survey II (n=467) were tested with ImmunoCAP ISAC against 103 allergen molecules. The presence of bronchial hyperresponsiveness was measured with a methacholine challenge test and bronchial inflammation with fraction of exhaled nitric oxide (Feno). A total of 38% of the controls and 72% of the asthmatic patients were sensitized against at least 1 of the allergen components (P<.0001). Asthma was independently related to having IgE antibodies against pollen (odds ratio=2.2) and perennial airway allergens (odds ratio=5.6), increased Feno was independently related to having IgE antibodies against food allergens and perennial allergens, while bronchial responsiveness was independently associated with having IgE antibodies against only perennial allergens. Sensitization to food allergens was related to asthma and increased Feno if IgE antibody against pollen allergens was present. Simultaneous sensitization to perennial, pollen, and food allergens involves the highest risk of asthma (odds ratio=18.3), bronchial inflammation, and responsiveness. Feno, bronchial responsiveness, and the risk of asthma increase with multiple sensitizations to different allergen groups. We show for the first time that the presence of IgE antibodies against food allergens is independently associated with increased Feno and increases the risk of asthma in subjects with simultaneous sensitization to pollen allergens.Swedish Agency for Innovation Systems Swedish Heart and Lung Foundation Vardal Foundation for Health Care Science and Allergy Research Swedish Association Against Asthma and Allergy Agnes and Mac Rudberg's Foundation Bror Hjerpstedt Foundation Phadia (Sweden

    Volatile organic compounds (VOC) in homes associated with asthma and lung function among adults in Northern Europe

    Get PDF
    Associations between measured specific VOC reported to be associated with dampness and microbial growth in dwellings and asthma, lung function were investigated in 159 adults (one adult/home) from three North European cities (Reykjavik, Uppsala and Tartu). Spirometry was performed and forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1) and FEV1/FVC were measured. Among 159 participants, 58% were females, 24.5% atopics, 25.8% current smokers and 41% reported dampness or mold at home. Dimethyl disulphide (p = 0.004), ethyl isobutyrate (p = 0.021) and ethyl 2-methylbutyrate (p = 0.035) were associated with asthma. Isobutanol (p = 0.043), 3-methyl-1-butanol (p = 0.020), 2-hexanone (p = 0.033), 1-octen-3-ol (p = 0.027), 2-methyl-1-butanol (p = 0.022) and 2-ethyl-1-hexanol (p = 0.045) were associated with lower FEV1. Isobutanol (p = 0.004), 3-methyl-1-butanol (p = 0.001), 2-heptanone (p = 0.047) and 2-methyl-1-butanol (p = 0.002) were associated with lower FEV1/FVC. The association between dimethyl disulphide and asthma was more pronounced in females (p for interaction 0.099). The association between 1-butanol and lower FEV1 was more pronounced in males (p for interaction 0.046). The associations between 3-octanone (p for interaction 0.064), 2-ethyl-1-hexanol (p for interaction 0.049) and lower FEV1, and between 2-heptanone (p for interaction 0.021), 3-octanone (p for interaction 0.008) and lower FEV1/FVC were stronger in homes with dampness/mold. Factor analysis identified one VOC factor related to asthma and two VOC factors related to lower lung function. Increased air concentrations of 2-heptanone, ethyl 2-methylbutyrate and ethyl isobutyrate were related to prescence of certain mold species (Aspergillus sp., Cladosporum sp. and Penicillium sp.) or building dampness. Some VOC were associated with type of dwelling, building age and pet keeping. In conclusion, some VOC reported to be associated with dampness and microbial growth can be associated with asthma and lower lung function in adults. Associations between these VOC and respiratory illness can be stronger in homes with dampness/mold. There can be gender differences in respiratory health effects when exposed to indoor VOC

    Airborne molds and bacteria, microbial volatile organic compounds (MVOC), plasticizers and formaldehyde in dwellings in three North European cities in relation to sick building syndrome (SBS).

    No full text
    To access publisher's full text version of this article. Please click on the hyperlink in Additional Links field.There are few studies on associations between airborne microbial exposure, formaldehyde, plasticizers in dwellings and the symptoms compatible with the sick building syndrome (SBS). As a follow-up of the European Community Respiratory Health Survey (ECRHS II), indoor measurements were performed in homes in three North European cities. The aim was to examine whether volatile organic compounds of possible microbial origin (MVOCs), and airborne levels of bacteria, molds, formaldehyde, and two plasticizers in dwellings were associated with the prevalence of SBS, and to study associations between MVOCs and reports on dampness and mold. The study included homes from three centers included in ECRHS II. A total of 159 adults (57% females) participated (19% from Reykjavik, 40% from Uppsala, and 41% from Tartu). A random sample and additional homes with a history of dampness were included. Exposure measurements were performed in the 159 homes of the participants. MVOCs were analyzed by GCMS with selective ion monitoring (SIM). Symptoms were reported in a standardized questionnaire. Associations were analyzed by multiple logistic regression. In total 30.8% reported any SBS (20% mucosal, 10% general, and 8% dermal symptoms) and 41% of the homes had a history of dampness and molds There were positive associations between any SBS and levels of 2-pentanol (P=0.002), 2-hexanone (P=0.0002), 2-pentylfuran (P=0.009), 1-octen-3-ol (P=0.002), formaldehyde (P=0.05), and 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate (Texanol) (P=0.05). 1-octen-3-ol (P=0.009) and 3-methylfuran (P=0.002) were associated with mucosal symptoms. In dwellings with dampness and molds, the levels of total bacteria (P=0.02), total mold (P=0.04), viable mold (P=0.02), 3-methylfuran (P=0.008) and ethyl-isobutyrate (P=0.02) were higher. In conclusion, some MVOCs like 1-octen-3-ol, formaldehyde and the plasticizer Texanol, may be a risk factor for sick building syndrome. Moreover, concentrations of airborne molds, bacteria and some other MVOCs were slightly higher in homes with reported dampness and mold

    New data analysis in a population study raises the hypothesis that particle size contributes to the pro-asthmatic potential of small pet animal allergens.

    No full text
    BACKGROUND: The size of inhaled particles influences where they deposit and theoretically should be important for the development of airway inflammation and responsiveness. Our aim was to assess if sensitization to smaller-sized aeroallergens relates to higher prevalence of treated asthma, increased airway responsiveness, and airway and systemic inflammation. METHODS: Molecular-based IgE antibody determination was done in 467 subjects. Sensitized subjects were grouped based on the particle size of the aeroallergen: (1) Large particles only (mainly pollen); (2) Medium-sized particles (sensitized to mainly mite and mold and possibly to large particles); and 3) Small particles (sensitized to pet allergens and possibly to medium- and/or large-sized particles). Airway responsiveness to methacholine, exhaled nitric oxide (FENO), and serum eosinophil cationic protein (S-ECP) were measured. Asthma and rhinitis were questionnaire-assessed. RESULTS: Subjects sensitized to small particles had higher prevalence of treated asthma (35% versus 10%, P &lt; 0.001), higher FENO50 (32 versus 17 ppb, P &lt; 0.001), higher S-ECP (10 versus 7.5 ng/mL, P = 0.04), and increased bronchial responsiveness (dose-response slope, 5.6 versus 7.5, P &lt; 0.001) compared with non-atopics. This was consistent after adjusting for potential confounders. Sensitization to only large or to medium and possibly also large aeroallergen particles was not related to any of these outcomes after adjustments. CONCLUSIONS: Sensitization to smaller particles was associated with a higher prevalence of asthma under treatment, higher airway responsiveness, and airway and systemic inflammation. Mapping of IgE sensitization to small particles might help to detect subjects having increased airway and systemic inflammation and bronchial responsiveness, indicating increased risk of developing asthma

    Beaufort, County of Ripon [cartographic material]

    No full text
    Geological map on a cadastral base, showing the occurrence of quartz reefs, shafts and alluvial deposits.; Also available in an electronic version via the Internet at: http://nla.gov.au/nla.map-rm2337-4; Library's copy has been trimmed

    Building dampness and mould in European homes in relation to climate, building characteristics and socio-economic status: The European Community Respiratory Health Survey ECRHS II.

    No full text
    We studied dampness and mold in homes in relation to climate, building characteristics and socio-economic status (SES) across Europe, for 7127 homes in 22 centers. A subsample of 3118 homes was inspected. Multilevel analysis was applied, including age, gender, center, SES, climate, and building factors. Self-reported water damage (10%), damp spots (21%), and mold (16%) in past year were similar as observed data (19% dampness and 14% mold). Ambient temperature was associated with self-reported water damage (OR=1.63 per 10°C; 95% CI 1.02-2.63), damp spots (OR=2.95; 95% CI 1.98-4.39), and mold (OR=2.28; 95% CI 1.04-4.67). Precipitation was associated with water damage (OR=1.12 per 100 mm; 95% CI 1.02-1.23) and damp spots (OR=1.11; 95% CI 1.02-1.20). Ambient relative air humidity was not associated with indoor dampness and mold. Older buildings had more dampness and mold (P<.001). Manual workers reported less water damage (OR=0.69; 95% CI 0.53-0.89) but more mold (OR=1.27; 95% CI 1.03-1.55) as compared to managerial/professional workers. There were correlations between reported and observed data at center level (Spearman rho 0.61 for dampness and 0.73 for mold). In conclusion, high ambient temperature and precipitation and high building age can be risk factors for dampness and mold in homes in Europe
    corecore