292 research outputs found

    Advancing Tests of Relativistic Gravity via Laser Ranging to Phobos

    Get PDF
    Phobos Laser Ranging (PLR) is a concept for a space mission designed to advance tests of relativistic gravity in the solar system. PLR's primary objective is to measure the curvature of space around the Sun, represented by the Eddington parameter Îł\gamma, with an accuracy of two parts in 10710^7, thereby improving today's best result by two orders of magnitude. Other mission goals include measurements of the time-rate-of-change of the gravitational constant, GG and of the gravitational inverse square law at 1.5 AU distances--with up to two orders-of-magnitude improvement for each. The science parameters will be estimated using laser ranging measurements of the distance between an Earth station and an active laser transponder on Phobos capable of reaching mm-level range resolution. A transponder on Phobos sending 0.25 mJ, 10 ps pulses at 1 kHz, and receiving asynchronous 1 kHz pulses from earth via a 12 cm aperture will permit links that even at maximum range will exceed a photon per second. A total measurement precision of 50 ps demands a few hundred photons to average to 1 mm (3.3 ps) range precision. Existing satellite laser ranging (SLR) facilities--with appropriate augmentation--may be able to participate in PLR. Since Phobos' orbital period is about 8 hours, each observatory is guaranteed visibility of the Phobos instrument every Earth day. Given the current technology readiness level, PLR could be started in 2011 for launch in 2016 for 3 years of science operations. We discuss the PLR's science objectives, instrument, and mission design. We also present the details of science simulations performed to support the mission's primary objectives.Comment: 25 pages, 10 figures, 9 table

    Cost of poor adherence to anti-hypertensive therapy in five European countries

    Get PDF
    The financial burden for EU health systems associated with cardiovascular disease (CV) has been estimated to be nearly €110 billion in 2006, corresponding to 10 % of total healthcare expenditure across EU or a mean €223 annual cost per capita. The main purpose of this study is to estimate the costs related to hypertension and the economic impact of increasing adherence to anti-hypertensive therapy in five European countries (Italy, Germany, France, Spain and England). A probabilistic prevalence-based decision tree model was developed to estimate the direct costs of CV related to hypertension (CV defined as: stroke, heart attack, heart failure) in five European countries. Our model considered adherence to hypertension treatment as a main driver of blood pressure (BP) control (BP < 140/90 mmHg). Relative risk of CV, based on controlled or uncontrolled BP group, was estimated from the Framingham Heart Study and national review data. Prevalence and cost data were estimated from national literature reviews. A national payer (NP) perspective for 10 years was considered. Probabilistic sensitivity analysis was performed in order to evaluate uncertainty around the results (given as 95 % confidence intervals). The model estimated a total of 8.6 million (1.4 in Italy, 3.3 in Germany, 1.2 in Spain, 1.8 in France and 0.9 in England) CV events related to hypertension over the 10-year time horizon. Increasing the adherence rate to anti-hypertensive therapy to 70 % (baseline value is different for each country) would lead to 82,235 fewer CV events (24,058 in Italy, 7,870 in Germany, 18,870 in Spain, 24,855 in France and 6,553 in England). From the NP perspective, the direct cost associated with hypertension was estimated to be €51.3 billion (8.1 in Italy, 17.1 in Germany, 12.2 in Spain, 8.8 in France and 5.0 in England). Increasing adherence to anti-hypertensive therapy to 70 % would save a total of €332 million (CI 95 %: €319-346 million) from the NPs perspective. This study is the first attempt to estimate the economic impact of non-adherence amongst patients with diagnosed hypertension in Europe, using data from five European countries (Italy, France, Germany, Spain and England). © 2014 Springer-Verlag Berlin Heidelberg

    Increased aortic stiffness and blood pressure in non-classic Pompe disease

    Get PDF
    Vascular abnormalities and glycogen accumulation in vascular smooth muscle fibres have been described in Pompe disease. Using carotid-femoral pulse wave velocity (cfPWV), the gold standard methodology for determining aortic stiffness, we studied whether aortic stiffness is increased in patients with Pompe disease. Eighty-four adult Pompe patients and 179 age- and gender-matched volunteers participated in this cross-sectional case-controlled study. Intima media thickness and the distensibility of the right common carotid artery were measured using a Duplex scanner. Aortic augmentation index, central pulse pressure, aortic reflexion time and cfPWV were assessed using the SphygmoCor¼ system. CfPWV was higher in patients than in volunteers (8.8 versus 7.4 m/s, p < 0.001). This difference was still present after adjustment for age, gender, mean arterial blood pressure (MAP), heart rate and diabetes mellitus (p = 0.001), and was shown by subgroup analysis to apply to the 40-59 years age group (p = 0.004) and 60+ years age group (p = 0.01), but not to younger age groups (p = 0.99). Except for a shorter aortic reflexion time (p = 0.02), indirect indicators of arterial stiffness did not differ between patients and volunteers. Relative to volunteers (20 %), more Pompe patients had a history of hypertension (36 %, p = 0.005), and the MAP was higher than in volunteers (100 versus 92 mmHg, p < 0.001). This study shows that patients with non-classic Pompe disease have increased aortic stiffness and blood pressure. Whether this is due to glycogen accumulation requires further investigation. To reduce the potential risk of cardiovascular diseases, we recommend that blood pressure and other common cardiovascular risk factors are monitored regularly

    Validation of the adherence evaluation of osteoporosis treatment (ADEOS) questionnaire for osteoporotic post-menopausal women

    Get PDF
    SUMMARY: We developed and validated a specific 12-item questionnaire to evaluate adherence to oral antiresorptive medication by post-menopausal osteoporotic women in everyday practice. Over the following 9 months, an index of ≀16 was associated with an increase in the risk of treatment discontinuation of 1.69 and of 2.10 for new patients who had started treatment within the previous year. INTRODUCTION: Adherence to medication in osteoporosis is poor. The goal of this study was to develop and validate a disease-specific questionnaire to evaluate adherence to treatment of women with post-menopausal osteoporosis taking oral antiresorptive medication. METHODS: A prototype adherence questionnaire with 45 items developed from patient interview, literature review, and physician opinion was evaluated in a sample of 350 post-menopausal women with osteoporosis treated in primary care. Item responses were matched against scores on the Morisky Medication Adherence Scale (MMAS). The most discriminant items were retained in the final questionnaire. Concurrent and predictive validity were assessed. RESULTS: Twelve items were associated with MMAS score at a probability level of 0.05. These were retained in the final questionnaire which provided an adherence index ranging from 0 to 22. An index of ≄20 was associated with a high probability of persistence and an index ≀ 16 with a high probability of treatment discontinuation in the following 9 months. CONCLUSIONS: The ADEOS-12 is a simple patient-reported measure to determine adherence to osteoporosis treatments with good concurrent and discriminant validity. This is the first disease-specific adherence measure to have been developed for osteoporosis

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE

    Get PDF
    This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model

    Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC

    Get PDF
    DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6  ×  6  ×  6 m 3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties

    Snowmass Neutrino Frontier: DUNE Physics Summary

    Get PDF
    The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of ÎŽCP. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter

    Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

    Full text link
    The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3σ\sigma (5σ\sigma) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3σ\sigma level with a 100 kt-MW-yr exposure for the maximally CP-violating values \delta_{\rm CP}} = \pm\pi/2. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest
    • 

    corecore