2,250 research outputs found

    Severe tissue damage and neurological deficit following extravasation of sodium hypochlorite solution during routine endodontic treatment.

    Get PDF
    Endodontic therapy is a routinely practised clinical procedure with few reported complications. Sodium hypochlorite is often used as an irrigant during this procedure, but severe complications may occur if this solution extravasates beyond the root apex. We present a case demonstrating some of the severe sequelae that can occur following the misuse of sodium hypochlorite during endodontic treatment of an upper lateral incisor, which also resulted in the previously unreported complication of isolated facial nerve weakness

    Dysaesthesia in the mental nerve distribution triggered by a foreign body: a case report

    Get PDF
    INTRODUCTION: Foreign bodies' entrapments in the mandibular and submandibular regions are quite common. CASE PRESENTATION: We report an unusual case of foreign body (amalgam filling) entrapment over the mental foramen causing dysaesthesia in the distribution of the mental nerve. An interesting sign was blue discoloration of the overlaying oral mucosa which was interpreted as amalgam tattooing. CONCLUSION: Surgical removal of the foreign object eliminated the reported symptoms

    Determination of ππ\pi\pi scattering lengths from measurement of π+π−\pi^+\pi^- atom lifetime

    Get PDF
    The DIRAC experiment at CERN has achieved a sizeable production of π+π−\pi^+\pi^- atoms and has significantly improved the precision on its lifetime determination. From a sample of 21227 atomic pairs, a 4% measurement of the S-wave ππ\pi\pi scattering length difference ∣a0−a2∣=(.0.2533−0.0078+0.0080∣stat.−0.0073+0.0078∣syst)Mπ+−1|a_0-a_2| = (.0.2533^{+0.0080}_{-0.0078}|_\mathrm{stat}.{}^{+0.0078}_{-0.0073}|_\mathrm{syst})M_{\pi^+}^{-1} has been attained, providing an important test of Chiral Perturbation Theory.Comment: 6 pages, 6 figure

    DIRAC Experiment and Test of Low-Energy QCD

    Get PDF
    The low-energy QCD predictions to be tested by the DIRAC experiment are revised. The experimental method, the setup characteristics and capabilities, along with first experimental results are reported. Preliminary analysis shows good detector performance: alignment error via Λ\Lambda mass measurement mΛ=1115.6MeV/c2m_\Lambda = 1115.6 MeV/c^2 with σ=0.92MeV/c2\sigma = 0.92 MeV/c^2, pπ−p \pi^- relative momentum resolution σQ≈2.7MeV/c\sigma_Q \approx 2.7 MeV/c, and evidence for $\pi^

    The HEV Ventilator

    Full text link
    HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The standard modes provided include PC-A/C(Pressure Assist Control),PC-A/C-PRVC(Pressure Regulated Volume Control), PC-PSV (Pressure Support Ventilation) and CPAP (Continuous Positive airway pressure). HEV is designed to support remote training and post market surveillance via a web interface and data logging to complement the standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the quality of the pressure curves and the reactivity of the trigger, delivering a global performance which will be applicable to ventilator needs beyond theCOVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with their performance evaluation.Comment: 34 pages, 18 figures, Extended version of the article submitted to PNA

    Differential branching fraction and angular analysis of the decay B0→K∗0ÎŒ+Ό−

    Get PDF
    The angular distribution and differential branching fraction of the decay B 0→ K ∗0 ÎŒ + ÎŒ − are studied using a data sample, collected by the LHCb experiment in pp collisions at s√=7 TeV, corresponding to an integrated luminosity of 1.0 fb−1. Several angular observables are measured in bins of the dimuon invariant mass squared, q 2. A first measurement of the zero-crossing point of the forward-backward asymmetry of the dimuon system is also presented. The zero-crossing point is measured to be q20=4.9±0.9GeV2/c4 , where the uncertainty is the sum of statistical and systematic uncertainties. The results are consistent with the Standard Model predictions

    Measurement of the relative rate of prompt χc0, χc1 and χc2 production at √s=7TeV

    Get PDF
    Prompt production of charmonium χc0, χc1 and χc2 mesons is studied using proton-proton collisions at the LHC at a centre-of-mass energy of √s=7TeV. The χc mesons are identified through their decay to J/ÏˆÎł, with J/ψ→Ό+mu− using photons that converted in the detector. A data sample, corresponding to an integrated luminosity of 1.0fb−1 collected by the LHCb detector, is used to measure the relative prompt production rate of χc1 and χc2 in the rapidity range 2.0<y<4.5 as a function of the J/ψ transverse momentum from 3 to 20 GeV/c. First evidence for χc0 meson production at a hadron collider is also presented

    Opposite-side flavour tagging of B mesons at the LHCb experiment

    Get PDF
    The calibration and performance of the oppositeside flavour tagging algorithms used for the measurements of time-dependent asymmetries at the LHCb experiment are described. The algorithms have been developed using simulated events and optimized and calibrated with B + →J/ψK +, B0 →J/ψK ∗0 and B0 →D ∗− ÎŒ + ΜΌ decay modes with 0.37 fb−1 of data collected in pp collisions at √ s = 7 TeV during the 2011 physics run. The oppositeside tagging power is determined in the B + → J/ψK + channel to be (2.10 ± 0.08 ± 0.24) %, where the first uncertainty is statistical and the second is systematic
    • 

    corecore