7 research outputs found

    Endotracheal tube placement with fibre optic sensing

    Get PDF
    Unrecognised oesophageal intubation is often described as a ‘Never Event’; an entirely preventable and extremely serious incident. However, there is still prevalence, with severe consequences for the patient. The current gold standards of visually confirming passage through the vocal cords, observing chest movement, and end-tidal capnography all have limitations. There is an opportunity for an alternative method to determine the correct endotracheal tube placement in the trachea. One such solution is described here, through the development of a compact fibre optic sensor integrated into a standard endotracheal tube. The sensor contains no electrical components inside the invasive portion of the device, and it is magnetic resonance imaging safe. The spectral characteristics of the trachea and oesophagus are observed using a fibre optic probe, with the presence of oxyhaemoglobin being used to distinguish the tissues. A novel epoxy sensor is then designed using plastic optical fibres. A rounded top with a square base sensor shape had the least impact on the overall performance of the ETT. Furthermore, by forming the sensor with two illumination fibres, pulse oximetry can be performed. A fibre separation distance between 1.27 and 2.54 mm is optimal. However, a Monte Carlo simulation demonstrates a viable separation of 0.5 to 3 mm. ThereforeHowever, by reducing this to 0.88 mm, a more compact sensor can be produced whilst still retaining a classification rate (average correct identification of trachea and oesophagus) of >89.2% in ex-vivo models. Two methods for emitting light perpendicularly to the fibre axis are explored, demonstrating that bending the fibres caused an optical power loss of 29.0%, whereas cleaving the fibres at 45° produced an 81.9% loss. The position of the sensor on the endotracheal tube is investigated, finding that integration behind the cuff is preferable. However, placement outside the main lumen of the ETT is also a viable option. Computational methods to process spectral measurements are developed. Data for these methods was provided by two experiments on two different sensor types, providing a high tissue classification rate for both the trachea and oesophagus. The first experiment consisted of 9 ex-vivo porcine samples, producing a correct tissue identification of up to 100.0%. The second consisted of 10 sensors on 1 ex-vivo porcine sample, yielding a maximum correct tissue identification of 89.2% when a support vector machine classifier was used. Application of the sensor in an animal study, which consisted of 3 porcine subjects, generated a maximum correct tissue identification of 98.31.6% using principal component analysis and aa support vector machine. The data were recorded over a combined time of 348 minutes, obtained during varying cuff pressures, endotracheal tube orientations, and movement. Finally, suggested future developments to the sensor design and computational methods demonstrate a potential route to improving tissue identification rates. Changes to the experimental protocol are described to verify classification rates. Concepts for exchanging the spectrometer for photodiodes and optical filters to reduce the cost of the opto-electronic units display potential. The technology has applications in wider healthcare, with examples of integration within naso-/oro- gastric tubes and other invasive medical devices given

    Endotracheal tube placement with fibre optic sensing

    Get PDF
    Unrecognised oesophageal intubation is often described as a ‘Never Event’; an entirely preventable and extremely serious incident. However, there is still prevalence, with severe consequences for the patient. The current gold standards of visually confirming passage through the vocal cords, observing chest movement, and end-tidal capnography all have limitations. There is an opportunity for an alternative method to determine the correct endotracheal tube placement in the trachea. One such solution is described here, through the development of a compact fibre optic sensor integrated into a standard endotracheal tube. The sensor contains no electrical components inside the invasive portion of the device, and it is magnetic resonance imaging safe. The spectral characteristics of the trachea and oesophagus are observed using a fibre optic probe, with the presence of oxyhaemoglobin being used to distinguish the tissues. A novel epoxy sensor is then designed using plastic optical fibres. A rounded top with a square base sensor shape had the least impact on the overall performance of the ETT. Furthermore, by forming the sensor with two illumination fibres, pulse oximetry can be performed. A fibre separation distance between 1.27 and 2.54 mm is optimal. However, a Monte Carlo simulation demonstrates a viable separation of 0.5 to 3 mm. ThereforeHowever, by reducing this to 0.88 mm, a more compact sensor can be produced whilst still retaining a classification rate (average correct identification of trachea and oesophagus) of >89.2% in ex-vivo models. Two methods for emitting light perpendicularly to the fibre axis are explored, demonstrating that bending the fibres caused an optical power loss of 29.0%, whereas cleaving the fibres at 45° produced an 81.9% loss. The position of the sensor on the endotracheal tube is investigated, finding that integration behind the cuff is preferable. However, placement outside the main lumen of the ETT is also a viable option. Computational methods to process spectral measurements are developed. Data for these methods was provided by two experiments on two different sensor types, providing a high tissue classification rate for both the trachea and oesophagus. The first experiment consisted of 9 ex-vivo porcine samples, producing a correct tissue identification of up to 100.0%. The second consisted of 10 sensors on 1 ex-vivo porcine sample, yielding a maximum correct tissue identification of 89.2% when a support vector machine classifier was used. Application of the sensor in an animal study, which consisted of 3 porcine subjects, generated a maximum correct tissue identification of 98.31.6% using principal component analysis and aa support vector machine. The data were recorded over a combined time of 348 minutes, obtained during varying cuff pressures, endotracheal tube orientations, and movement. Finally, suggested future developments to the sensor design and computational methods demonstrate a potential route to improving tissue identification rates. Changes to the experimental protocol are described to verify classification rates. Concepts for exchanging the spectrometer for photodiodes and optical filters to reduce the cost of the opto-electronic units display potential. The technology has applications in wider healthcare, with examples of integration within naso-/oro- gastric tubes and other invasive medical devices given

    Prison(er) auto/biography, 'true crime', and teaching, learning, and research in criminology

    Get PDF
    The main aim of this essay is to explore prisoner life writing within the specific, richly and multiply dependent context of teaching and learning undergraduate criminology at an English university, from the authorial viewpoint of a teacher and her students as budding criminologists and co-authors. This article seeks to redress a continuing resistance to life history approaches in the teaching of criminology, despite the discipline being formally devoted to the understanding of the meaning and experience of imprisonment in all its forms and consequences. What follows is a trucated narrative of what students had to say on the fascinating subjects of prisoner auto/biography and its place in popular and expert discourses on crime, criminality, and punishment, contextualised within the academic discipline of criminology

    Intra-tracheal multiplexed sensing of contact pressure and perfusion

    Get PDF
    Incorrect endotracheal tube (ETT) cuff inflation pressure causes significant problems for intubated patients. The technical development and first in vivo use of a smart ETT for measurements at the cuff-trachea interface during mechanical ventilation are described. The intra-tracheal multiplexed sensing (iTraXS) ETT contains integrated optical fibre sensors to measure contact pressure and blood perfusion. The device is tested during mechanical ventilation in a porcine model (N=6). For contact pressure, signals were obtained in all 30 measurements. For perfusion, data could be obtained in all 33 measurements. In the 3 cases where the cuff was inflated to an artificially high-level, blood occlusion is observed