179 research outputs found
Foam posturography: standing on foam is not equivalent to standing with decreased rapidly adapting mechanoreceptive sensation
This is an accepted manuscript of an article published by Springer in Experimental Brain Research on 01/12/2010, available online: https://doi.org/10.1007/s00221-010-2498-6
The accepted version of the publication may differ from the final published version.Standing on a foam surface is believed to exaggerate balance deficits by decreasing the reliability of somatosensory information from cutaneous mechanoreceptors on the plantar soles (i.e. base of feet) and by altering the effectiveness of ankle torque. The aim was to further document the nature of foam posturography testing by comparing between standing on foam and standing with decreased Rapidly Adapting Mechanoreceptive Sensation (RAMS). Sixteen healthy adults (mean age 20.8 years) were tested with posturography, standing with eyes open and closed on a solid surface and on foam, with and without decreased plantar RAMS. Standing balance was measured as torque variance and further analyzed by being divided into three spectral categories. Plantar cutaneous hypothermic anesthesia by ice-cooling was used to decrease RAMS. Plantar mechanoreceptive sensation was precisely determined with tactile sensitivity and vibration perception tests. Vibration perception was significantly decreased by hypothermic anesthesia, but tactile sensitivity was not. The anterior-posterior torque variance was significantly larger for frequencies less than 0.1 Hz under eyes closed conditions when standing on a solid surface with decreased RAMS compared to normal sensation. No effect of decreased RAMS was seen with eyes open on a solid surface, nor on foam with eyes open or closed. Decreased RAMS produced body sway responses on a solid surface that were different in spectral composition, amplitude, direction and that responded differently to vision compared with standing on foam. Hence, this study showed that RAMS contributes to postural control but reduction in RAMS does not produce a similar challenge as standing on foam.Published versio
Spectra of supernovae in the nebular phase
When supernovae enter the nebular phase after a few months, they reveal
spectral fingerprints of their deep interiors, glowing by radioactivity
produced in the explosion. We are given a unique opportunity to see what an
exploded star looks like inside. The line profiles and luminosities encode
information about physical conditions, explosive and hydrostatic
nucleosynthesis, and ejecta morphology, which link to the progenitor properties
and the explosion mechanism. Here, the fundamental properties of spectral
formation of supernovae in the nebular phase are reviewed. The formalism
between ejecta morphology and line profile shapes is derived, including effects
of scattering and absorption. Line luminosity expressions are derived in
various physical limits, with examples of applications from the literature. The
physical processes at work in the supernova ejecta, including gamma-ray
deposition, non-thermal electron degradation, ionization and excitation, and
radiative transfer are described and linked to the computation and application
of advanced spectral models. Some of the results derived so far from
nebular-phase supernova analysis are discussed.Comment: Book chapter for 'Handbook of Supernovae,' edited by Alsabti and
Murdin, Springer. 51 pages, 14 figure
Effects of dyslexia on postural control in adults
This is an accepted manuscript of an article published by Wiley in Dyslexia on 01/02/2010, available online: https://doi.org/10.1002/dys.398
The accepted version of the publication may differ from the final published version.Dyslexia has been shown to affect postural control. The aim of the present study was to investigate the difference in postural stability measured as torque variance in an adult dyslexic group (n =14, determined using the Adult Dyslexia Checklist (ADCL) and nonsense word repetition test) and an adult nonâdyslexic group (n =39) on a firm surface and on a foam block and with eyes open and eyes closed. Another aim was to investigate the correlation between ADCL scores and postural stability.
Findings showed that ADCL scores correlated with torque variance in the anteroposterior direction on foam with eyes closed (p =0.001) and in the lateral direction on the foam surface with eyes closed (p =0.040) and open (p =0.010). General Linear Model analysis showed that high dyslexia scores were associated with increased torque variance (p <0.001). However, we found no significant difference between dyslexics and nonâdyslexics, though there were indications of larger torque variance in the dyslexics.
The findings suggest that adults with high dyslexic ADCL scores may experience subâclinical balance deficits. Hence, assessing motor ability and postural control in those with high ADCL scores is motivated. Copyright © 2010 John Wiley & Sons, Ltd.Published versio
Postural instability in an immersive Virtual Reality adapts with repetition and includes directional and gender specific effects
The ability to handle sensory conflicts and use the most appropriate sensory information is vital for successful recovery of human postural control after injury. The objective was to determine if virtual reality (VR) could provide a vehicle for sensory training, and determine the temporal and spatial nature of such adaptive changes. Twenty healthy subjects participated in the study (10 females). The subjects watched a 90-second VR simulation of railroad (rollercoaster) motion in mountainous terrain during five repeated simulations, while standing on a force platform that recorded their stability. The immediate response to watching the VR movie was an increased level of postural instability. Repeatedly watching the same VR movie significantly reduced both the anteroposterior (62%, pâ<â0.001) and lateral (47%, pâ=â0.001) energy used. However, females adapted more slowly to the VR stimuli as reflected by higher use of total (pâ=â0.007), low frequency (pâ=â0.027) and high frequency (pâ=â0.026) energy. Healthy subjects can significantly adapt to a multidirectional, provocative, visual environment after 4â5 repeated sessions of VR. Consequently, VR technology might be an effective tool for rehabilitation involving visual desensitisation. However, some females may require more training sessions to achieve effects with VR
Differential postural effects of plantar-flexor muscles fatigue under normal, altered and improved vestibular and neck somatosensory conditions
The aim of the present study was to assess the effects of plantar-flexor
muscles fatigue on postural control during quiet standing under normal, altered
and improved vestibular and neck somatosensory conditions. To address this
objective, young male university students were asked to stand upright as still
as possible with their eyes closed in two conditions of No Fatigue and Fatigue
of the plantar-flexor muscles. In Experiment 1 (n=15), the postural task was
executed in two Neutral head and Head tilted backward postures, recognized to
degrade vestibular and neck somatosensory information. In Experiment 2 (n=15),
the postural task was executed in two conditions of No tactile and Tactile
stimulation of the neck provided by the application of strips of adhesive
bandage to the skin over and around the neck. Centre of foot pressure
displacements were recorded using a force platform. Results showed that (1) the
Fatigue condition yielded increased CoP displacements relative to the No
Fatigue condition (Experiment 1 and Experiment 2), (2) this destabilizing
effect was more accentuated in the Head tilted backward posture than Neutral
head posture (Experiment 1) and (3) this destabilizing effect was less
accentuated in the condition of Tactile stimulation than that of No tactile
stimulation of the neck (Experiment 2). In the context of the multisensory
control of balance, these results suggest an increased reliance on vestibular
and neck somatosensory information for controlling posture during quiet
standing in condition of altered ankle neuromuscular function
Hypernovae and Other Black-Hole-Forming Supernovae
During the last few years, a number of exceptional core-collapse supernovae
(SNe) have been discovered. Their kinetic energy of the explosions are larger
by more than an order of magnitude than the typical values for this type of
SNe, so that these SNe have been called `Hypernovae'. We first describe how the
basic properties of hypernovae can be derived from observations and modeling.
These hypernovae seem to come from rather massive stars, thus forming black
holes. On the other hand, there are some examples of massive SNe with only a
small kinetic energy. We suggest that stars with non-rotating black holes are
likely to collapse "quietly" ejecting a small amount of heavy elements (Faint
supernovae). In contrast, stars with rotating black holes are likely to give
rise to very energetic supernovae (Hypernovae). We present distinct
nucleosynthesis features of these two types of "black-hole-forming" supernovae.
Hypernova nucleosynthesis is characterized by larger abundance ratios
(Zn,Co,V,Ti)/Fe and smaller (Mn,Cr)/Fe. Nucleosynthesis in Faint supernovae is
characterized by a large amount of fall-back. We show that the abundance
pattern of the most Fe deficient star, HE0107-5240, and other extremely
metal-poor carbon-rich stars are in good accord with those of
black-hole-forming supernovae, but not pair-instability supernovae. This
suggests that black-hole-forming supernovae made important contributions to the
early Galactic (and cosmic) chemical evolution.Comment: 49 pages, to be published in "Stellar Collapse" (Astrophysics and
Space Science; Kluwer) ed. C. L. Fryer (2003
A hot and fast ultra-stripped supernova that likely formed a compact neutron star binary.
Compact neutron star binary systems are produced from binary massive stars through stellar evolution involving up to two supernova explosions. The final stages in the formation of these systems have not been directly observed. We report the discovery of iPTF 14gqr (SN 2014ft), a type Ic supernova with a fast-evolving light curve indicating an extremely low ejecta mass (â0.2 solar masses) and low kinetic energy (â2 Ă 1050 ergs). Early photometry and spectroscopy reveal evidence of shock cooling of an extended helium-rich envelope, likely ejected in an intense pre-explosion mass-loss episode of the progenitor. Taken together, we interpret iPTF 14gqr as evidence for ultra-stripped supernovae that form neutron stars in compact binary systems
SN 2017dio: A Type-Ic Supernova Exploding in a Hydrogen-rich Circumstellar Medium
SN 2017dio shows both spectral characteristics of a type-Ic supernova (SN) and signs of a hydrogen-rich circumstellar medium (CSM). Prominent, narrow emission lines of H and He are superposed on the continuum. Subsequent evolution revealed that the SN ejecta are interacting with the CSM. The initial SN Ic identification was confirmed by removing the CSM interaction component from the spectrum and comparing with known SNe Ic and, reversely, adding a CSM interaction component to the spectra of known SNe Ic and comparing them to SN 2017dio. Excellent agreement was obtained with both procedures, reinforcing the SN Ic classification. The light curve constrains the pre-interaction SN Ic peak absolute magnitude to be around mag. No evidence of significant extinction is found, ruling out a brighter luminosity required by an SN Ia classification. These pieces of evidence support the view that SN 2017dio is an SN Ic, and therefore the first firm case of an SN Ic with signatures of hydrogen-rich CSM in the early spectrum. The CSM is unlikely to have been shaped by steady-state stellar winds. The mass loss of the progenitor star must have been intense, ( km sâ1) 10,000 km sâ1)â3 M â yrâ1, peaking at a few decades before the SN. Such a high mass-loss rate might have been experienced by the progenitor through eruptions or binary stripping
SN2012dn from early to late times: 09dc-like supernovae reassessed
As a candidate âsuper-Chandrasekharâ or 09dc-like Type Ia supernova (SN Ia), SN 2012dn shares many characteristics with other members of this remarkable class of objects but lacks their extraordinary luminosity. Here, we present and discuss the most comprehensive optical data set of this SN to date, comprised of a densely sampled series of early-time spectra obtained within the Nearby Supernova Factory project, plus photometry and spectroscopy obtained at the Very Large Telescope about 1âyr after the explosion. The light curves, colour curves, spectral time series, and ejecta velocities of SN 2012dn are compared with those of other 09dc-like and normal SNe Ia, the overall variety within the class of 09dc-like SNe Ia is discussed, and new criteria for 09dc-likeness are proposed. Particular attention is directed to additional insight that the late-phase data provide. The nebular spectra show forbidden lines of oxygen and calcium, elements that are usually not seen in late-time spectra of SNe Ia, while the ionization state of the emitting iron plasma is low, pointing to low ejecta temperatures and high densities. The optical light curves are characterized by an enhanced fading starting âŒ60âd after maximum and very low luminosities in the nebular phase, which is most readily explained by unusually early formation of clumpy dust in the ejecta. Taken together, these effects suggest a strongly perturbed ejecta density profile, which might lend support to the idea that 09dc-like characteristics arise from a brief episode of interaction with a hydrogen-deficient envelope during the first hours or days after the explosion
Physiological basis and image processing in functional magnetic resonance imaging: Neuronal and motor activity in brain
Functional magnetic resonance imaging (fMRI) is recently developing as imaging modality used for mapping hemodynamics of neuronal and motor event related tissue blood oxygen level dependence (BOLD) in terms of brain activation. Image processing is performed by segmentation and registration methods. Segmentation algorithms provide brain surface-based analysis, automated anatomical labeling of cortical fields in magnetic resonance data sets based on oxygen metabolic state. Registration algorithms provide geometric features using two or more imaging modalities to assure clinically useful neuronal and motor information of brain activation. This review article summarizes the physiological basis of fMRI signal, its origin, contrast enhancement, physical factors, anatomical labeling by segmentation, registration approaches with examples of visual and motor activity in brain. Latest developments are reviewed for clinical applications of fMRI along with other different neurophysiological and imaging modalities
- âŠ