21 research outputs found

    Hybrid Surgery for Severe Mitral Valve Calcification: Limitations and Caveats for an Open Transcatheter Approach

    Get PDF
    Background and Objectives: Mitral stenosis with extensive mitral annular calcification (MAC) remains surgically challenging in respect to clinical outcome. Prolonged surgery time with imminent ventricular rupture and systolic anterior motion can be considered as a complex of causal factors. The aim of our alternative hybrid approach was to reduce the risk of annual rupture and paravalvular leaks and to avoid obstruction of the outflow tract. A review of the current literature was also carried out. Materials and Methods: Six female patients (mean age 76 +/- 9 years) with severe mitral valve stenosis and severely calcified annulus underwent an open implantation of an Edwards Sapien 3 prosthesis on cardiopulmonary bypass. Our hybrid approach involved resection of the anterior mitral leaflet, placement of anchor sutures and the deployment of a balloon expanded prosthesis under visual control. Concomitant procedures were carried out in three patients. Results: The mean duration of cross-clamping was 95 +/- 31 min and cardiopulmonary bypass was 137 +/- 60 min. The perioperative TEE showed in three patients an inconspicuous, heart valve-typical gradient on all implanted prostheses and a clinically irrelevant paravalvular leakage occurred in the anterior annulus. In the left ventricular outflow tract, mild to moderately elevated gradients were recorded. No adverse cerebrovascular events and pacemaker implantations were observed. All but one patient survived to discharge. Survival at one year was 83.3%. Conclusions: This off label implantation of the Edwards Sapien 3 prosthesis may be considered as a suitable bail-out approach for patients at high-risk for mitral valve surgery or deemed inoperable due to extensive MAC

    Immediate surgical coronary revascularisation in patients presenting with acute myocardial infarction

    Get PDF
    Background: The number of patients presenting with acute myocardial infarction (AMI) and being untreatable by interventional cardiologists increased during the last years. Previous experience in emergency coronary artery bypass grafting (CABG) in these patients spurred us towards a more liberal acceptance for surgery. Following a prospective protocol, patients were operated on and further analysed. Methods: Within a two year interval, 127 patients (38 female, age 68 +/- 12 years, EuroScore (ES) II 6.7 +/- 7.2\%) presenting with AMI (86 non-ST-elevated myocardial infarction (NSTEMI), 41 STEMI) were immediately accepted for emergency CABG and operated on within six hours after cardiac catheterisation (77\% three-vessel-disease, 47\% left main stem stenosis, 11\% cardiogenic shock, 21\% preoperative intraaortic balloon pump (IABP), left ventricular ejection fraction 48 +/- 15\%). Results: 30-day-mortality was 6\% (8 patients, 2 NSTEMI (2\%) 6 STEMI (15\%), p=0.014). Complete revascularisation could be achieved in 80\% of the patients using 2 +/- 1 grafts and 3 +/- 1 distal anastomoses. In total, 66\% were supported by IABP, extracorporal life support (ECLS) systems were implanted in two patients. Logistic regression analysis revealed the ES II as an independent risk factor for mortality (p<0.001, HR 1.216, 95\%-CI-Intervall 1.082-1.366). Conclusions: Quo ad vitam, results of emergency CABG for patients presenting with NSTEMI can be compared with those of elective revascularisation. Complete revascularisation obviously offers a clear benefit for the patients. Mortality in patients presenting with STEMI and cardiogenic shock is substantially high. For these patients, other concepts regarding timing of surgical revascularisation and bridging until surgery need to be taken into consideration

    Hybrid Surgery for Severe Mitral Valve Calcification: Limitations and Caveats for an Open Transcatheter Approach

    Get PDF
    Background and Objectives: Mitral stenosis with extensive mitral annular calcification (MAC) remains surgically challenging in respect to clinical outcome. Prolonged surgery time with imminent ventricular rupture and systolic anterior motion can be considered as a complex of causal factors. The aim of our alternative hybrid approach was to reduce the risk of annual rupture and paravalvular leaks and to avoid obstruction of the outflow tract. A review of the current literature was also carried out. Materials and Methods: Six female patients (mean age 76 9 years) with severe mitral valve stenosis and severely calcified annulus underwent an open implantation of an Edwards Sapien 3 prosthesis on cardiopulmonary bypass. Our hybrid approach involved resection of the anterior mitral leaflet, placement of anchor sutures and the deployment of a balloon expanded prosthesis under visual control. Concomitant procedures were carried out in three patients. Results: The mean duration of cross-clamping was 95 31 min and cardiopulmonary bypass was 137 60 min. The perioperative TEE showed in three patients an inconspicuous, heart valve-typical gradient on all implanted prostheses and a clinically irrelevant paravalvular leakage occurred in the anterior annulus. In the left ventricular outflow tract, mild to moderately elevated gradients were recorded. No adverse cerebrovascular events and pacemaker implantations were observed. All but one patient survived to discharge. Survival at one year was 83.3%. Conclusions: This “off label” implantation of the Edwards Sapien 3 prosthesis may be considered as a suitable bail-out approach for patients at high-risk for mitral valve surgery or deemed inoperable due to extensive MAC

    The physical oceanography of the transport of floating marine debris

    Get PDF
    Marine plastic debris floating on the ocean surface is a major environmental problem. However, its distribution in the ocean is poorly mapped, and most of the plastic waste estimated to have entered the ocean from land is unaccounted for. Better understanding of how plastic debris is transported from coastal and marine sources is crucial to quantify and close the global inventory of marine plastics, which in turn represents critical information for mitigation or policy strategies. At the same time, plastic is a unique tracer that provides an opportunity to learn more about the physics and dynamics of our ocean across multiple scales, from the Ekman convergence in basin-scale gyres to individual waves in the surfzone. In this review, we comprehensively discuss what is known about the different processes that govern the transport of floating marine plastic debris in both the open ocean and the coastal zones, based on the published literature and referring to insights from neighbouring fields such as oil spill dispersion, marine safety recovery, plankton connectivity, and others. We discuss how measurements of marine plastics (both in situ and in the laboratory), remote sensing, and numerical simulations can elucidate these processes and their interactions across spatio-temporal scales

    New insights into valve-related intramural and intracellular bacterial diversity in infective endocarditis

    Get PDF
    Aims: In infective endocarditis (IE), a severe inflammatory disease of the endocardium with an unchanged incidence and mortality rate over the past decades, only 1% of the cases have been described as polymicrobial infections based on microbiological approaches. The aim of this study was to identify potential biodiversity of bacterial species from infected native and prosthetic valves. Furthermore, we compared the ultrastructural micro-environments to detect the localization and distribution patterns of pathogens in IE. Material and methods: Using next-generation sequencing (NGS) of 16S rDNA, which allows analysis of the entire bacterial community within a single sample, we investigated the biodiversity of infectious bacterial species from resected native and prosthetic valves in a clinical cohort of 8 IE patients. Furthermore, we investigated the ultrastructural infected valve micro-environment by focused ion beam scanning electron microscopy (FIB-SEM). Results: Biodiversity was detected in 7 of 8 resected heart valves. This comprised 13 bacterial genera and 16 species. In addition to 11 pathogens already described as being IE related, 5 bacterial species were identified as having a novel association. In contrast, valve and blood culture-based diagnosis revealed only 4 species from 3 bacterial genera and did not show any relevant antibiotic resistance. The antibiotics chosen on this basis for treatment, however, did not cover the bacterial spectra identified by our amplicon sequencing analysis in 4 of 8 cases. In addition to intramural distribution patterns of infective bacteria, intracellular localization with evidence of bacterial immune escape mechanisms was identified. Conclusion: The high frequency of polymicrobial infections, pathogen diversity, and intracellular persistence of common IE-causing bacteria may provide clues to help explain the persistent and devastating mortality rate observed for IE. Improved bacterial diagnosis by 16S rDNA NGS that increases the ability to tailor antibiotic therapy may result in improved outcomes

    Hybrid Surgery for Severe Mitral Valve Calcification: Limitations and Caveats for an Open Transcatheter Approach

    No full text
    Background and Objectives: Mitral stenosis with extensive mitral annular calcification (MAC) remains surgically challenging in respect to clinical outcome. Prolonged surgery time with imminent ventricular rupture and systolic anterior motion can be considered as a complex of causal factors. The aim of our alternative hybrid approach was to reduce the risk of annual rupture and paravalvular leaks and to avoid obstruction of the outflow tract. A review of the current literature was also carried out. Materials and Methods: Six female patients (mean age 76 ± 9 years) with severe mitral valve stenosis and severely calcified annulus underwent an open implantation of an Edwards Sapien 3 prosthesis on cardiopulmonary bypass. Our hybrid approach involved resection of the anterior mitral leaflet, placement of anchor sutures and the deployment of a balloon expanded prosthesis under visual control. Concomitant procedures were carried out in three patients. Results: The mean duration of cross-clamping was 95 ± 31 min and cardiopulmonary bypass was 137 ± 60 min. The perioperative TEE showed in three patients an inconspicuous, heart valve-typical gradient on all implanted prostheses and a clinically irrelevant paravalvular leakage occurred in the anterior annulus. In the left ventricular outflow tract, mild to moderately elevated gradients were recorded. No adverse cerebrovascular events and pacemaker implantations were observed. All but one patient survived to discharge. Survival at one year was 83.3%. Conclusions: This “off label” implantation of the Edwards Sapien 3 prosthesis may be considered as a suitable bail-out approach for patients at high-risk for mitral valve surgery or deemed inoperable due to extensive MAC

    Hybrid Surgery for Severe Mitral Valve Calcification: Limitations and Caveats for an Open Transcatheter Approach

    No full text
    Background and Objectives: Mitral stenosis with extensive mitral annular calcification (MAC) remains surgically challenging in respect to clinical outcome. Prolonged surgery time with imminent ventricular rupture and systolic anterior motion can be considered as a complex of causal factors. The aim of our alternative hybrid approach was to reduce the risk of annual rupture and paravalvular leaks and to avoid obstruction of the outflow tract. A review of the current literature was also carried out. Materials and Methods: Six female patients (mean age 76 9 years) with severe mitral valve stenosis and severely calcified annulus underwent an open implantation of an Edwards Sapien 3 prosthesis on cardiopulmonary bypass. Our hybrid approach involved resection of the anterior mitral leaflet, placement of anchor sutures and the deployment of a balloon expanded prosthesis under visual control. Concomitant procedures were carried out in three patients. Results: The mean duration of cross-clamping was 95 31 min and cardiopulmonary bypass was 137 60 min. The perioperative TEE showed in three patients an inconspicuous, heart valve-typical gradient on all implanted prostheses and a clinically irrelevant paravalvular leakage occurred in the anterior annulus. In the left ventricular outflow tract, mild to moderately elevated gradients were recorded. No adverse cerebrovascular events and pacemaker implantations were observed. All but one patient survived to discharge. Survival at one year was 83.3%. Conclusions: This “off label” implantation of the Edwards Sapien 3 prosthesis may be considered as a suitable bail-out approach for patients at high-risk for mitral valve surgery or deemed inoperable due to extensive MAC

    Single-centre retrospective evaluation of intraoperative hemoadsorption in left-sided acute infective endocarditis

    Full text link
    Background: Cardiac surgery in patients with infective endocarditis (IE) is still associated with high mortality and morbidityan already present inflammation might further be aggravated due to a cardiopulmonary bypass-induced dysregulated immune response. Intraoperative hemoadsorption therapy may attenuate this septic response. Our objective was therefore to assess the efficacy of intraoperative hemoadsorption in active left-sided native- and prosthetic infective endocarditis. Methods: Consecutive high-risk patients with active left-sided infective endocarditis were enrolled between January 2015 and April 2021. Patients with intraoperative hemoadsorption (Cytosorbents, Princeton, NJ, USA) were compared to patients without hemoadsorption (control). Endpoints were the incidence of postoperative sepsis, sepsis-associated death and in-hospital mortality. Predictors for sepsis-associated mortality and in-hospital mortality were analysed by multivariable logistic regression. Results: A total of 202 patients were included, 135 with active left-sided native and 67 with prosthetic valve infective endocarditis. Ninety-nine patients received intraoperative hemoadsorption and 103 patients did not. Ninety-nine propensity-matched pairs were selected for final analyses. Postoperative sepsis and sepsis-related mortality was reduced in the hemoadsorption group (22.2% vs. 39.4%, p = 0.014 and 8.1% vs. 22.2%, p = 0.01, respectively). In-hospital mortality tended to be lower in the hemoadsorption group (14.1% vs. 26.3%, p = 0.052). Key predictors for sepsis-associated mortality and in-hospital mortality were preoperative inotropic support, lactate-levels 24 h after surgery, C-reactive protein levels on postoperative day 1, chest tube output, cumulative inotropes and white blood cell counts on postoperative day 2, and new onset of dialysis. Multivariate regression analysis revealed intraoperative hemoadsorption to be associated with lower sepsis-associated (OR 0.09, 95% CI 0.013–0.62, p = 0.014) as well as in-hospital mortality (OR 0.069, 95% CI 0.006–0.795, p = 0.032). Conclusions: Intraoperative hemoadsorption holds promise to reduce sepsis and sepsis-associated mortality after cardiac surgery for active left-sided native and prosthetic valve infective endocarditis

    Hybrid Surgery for Severe Mitral Valve Calcification: Limitations and Caveats for an Open Transcatheter Approach

    No full text
    Background and Objectives: Mitral stenosis with extensive mitral annular calcification (MAC) remains surgically challenging in respect to clinical outcome. Prolonged surgery time with imminent ventricular rupture and systolic anterior motion can be considered as a complex of causal factors. The aim of our alternative hybrid approach was to reduce the risk of annual rupture and paravalvular leaks and to avoid obstruction of the outflow tract. A review of the current literature was also carried out. Materials and Methods: Six female patients (mean age 76 9 years) with severe mitral valve stenosis and severely calcified annulus underwent an open implantation of an Edwards Sapien 3 prosthesis on cardiopulmonary bypass. Our hybrid approach involved resection of the anterior mitral leaflet, placement of anchor sutures and the deployment of a balloon expanded prosthesis under visual control. Concomitant procedures were carried out in three patients. Results: The mean duration of cross-clamping was 95 31 min and cardiopulmonary bypass was 137 60 min. The perioperative TEE showed in three patients an inconspicuous, heart valve-typical gradient on all implanted prostheses and a clinically irrelevant paravalvular leakage occurred in the anterior annulus. In the left ventricular outflow tract, mild to moderately elevated gradients were recorded. No adverse cerebrovascular events and pacemaker implantations were observed. All but one patient survived to discharge. Survival at one year was 83.3%. Conclusions: This “off label” implantation of the Edwards Sapien 3 prosthesis may be considered as a suitable bail-out approach for patients at high-risk for mitral valve surgery or deemed inoperable due to extensive MAC
    corecore