1,161 research outputs found

    Manchester Clinical Placement Index (MCPI): Conditions for medical students’ learning in hospital and community placements

    Get PDF
    The drive to quality-manage medical education has created a need for valid measurement instruments. Validity evidence includes the theoretical and contextual origin of items, choice of response processes, internal structure, and interrelationship of a measure’s variables. This research set out to explore the validity and potential utility of an 11-item measurement instrument, whose theoretical and empirical origins were in an Experience Based Learning model of how medical students learn in communities of practice (COPs), and whose contextual origins were in a community-oriented, horizontally integrated, undergraduate medical programme. The objectives were to examine the psychometric properties of the scale in both hospital and community COPs and provide validity evidence to support using it to measure the quality of placements. The instrument was administered twice to students learning in both hospital and community placements and analysed using exploratory factor analysis and a generalizability analysis. 754 of a possible 902 questionnaires were returned (84% response rate), representing 168 placements. Eight items loaded onto two factors, which accounted for 78% of variance in the hospital data and 82% of variance in the community data. One factor was the placement learning environment, whose five constituent items were how learners were received at the start of the placement, people’s supportiveness, and the quality of organisation, leadership, and facilities. The other factor represented the quality of training—instruction in skills, observing students performing skills, and providing students with feedback. Alpha coefficients ranged between 0.89 and 0.93 and there were no redundant or ambiguous items. Generalisability analysis showed that between 7 and 11 raters would be needed to achieve acceptable reliability. There is validity evidence to support using the simple 8-item, mixed methods Manchester Clinical Placement Index to measure key conditions for undergraduate medical students’ experience based learning: the quality of the learning environment and the training provided within it. Its conceptual orientation is towards Communities of Practice, which is a dominant contemporary theory in undergraduate medical education

    Report of the Working Group on `W Mass and QCD' (Phenomenology Workshop on LEP2 Physics, Oxford, April 1997)

    Get PDF
    The W Mass and QCD Working Group discussed a wide variety of topics relating to present and future measurements of M(W) at LEP2, including QCD backgrounds to W+W- production. Particular attention was focused on experimental issues concerning the direct reconstruction and threshold mass measurements, and on theoretical and experimental issues concerning the four jet final state. This report summarises the main conclusions.Comment: 43 pages LaTeX and 15 encapsulated postscript figures. Uses epsfig and ioplppt macros. Full Proceedings to be published in Journal of Physics

    Interim Design Report

    Get PDF
    The International Design Study for the Neutrino Factory (the IDS-NF) was established by the community at the ninth "International Workshop on Neutrino Factories, super-beams, and beta- beams" which was held in Okayama in August 2007. The IDS-NF mandate is to deliver the Reference Design Report (RDR) for the facility on the timescale of 2012/13. In addition, the mandate for the study [3] requires an Interim Design Report to be delivered midway through the project as a step on the way to the RDR. This document, the IDR, has two functions: it marks the point in the IDS-NF at which the emphasis turns to the engineering studies required to deliver the RDR and it documents baseline concepts for the accelerator complex, the neutrino detectors, and the instrumentation systems. The IDS-NF is, in essence, a site-independent study. Example sites, CERN, FNAL, and RAL, have been identified to allow site-specific issues to be addressed in the cost analysis that will be presented in the RDR. The choice of example sites should not be interpreted as implying a preferred choice of site for the facility

    Foreign policy beliefs and support for Stephen Harper and the Conservative Party

    Get PDF
    Similar to other recent Canadian elections, foreign policy did not feature prominently in the 2011 federal election campaign. In fact, many doubt Canadian public opinion on international affairs is linked to the actions taken by recent Governments. In this paper, we examine Canadian public opinion toward a range of foreign policy issues and argue that the survey questions measure two latent dimensions —militarism and internationalism. Our survey evidence indicates the existence of an “issue public” which is prepared to endorse military action and is skeptical of human rights and overseas aid programs, and this group is far more supportive of Prime Minister Harper and the Conservative Party than other Canadians. The absence of an elite discussion, either among politicians or between media elites, about the direction of Canadian foreign policy does not prevent the Canadian voter from thinking coherently about questions pertaining to this issue domain and employing these beliefs to support or oppose political parties and their leaders

    The design, construction and performance of the MICE scintillating fibre trackers

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2011 ElsevierCharged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and simulation software and the data-acquisition system. Finally, the performance of the MICE tracker, determined using cosmic rays, is presented.This work was supported by the Science and Technology Facilities Council under grant numbers PP/E003214/1, PP/E000479/1, PP/E000509/1, PP/E000444/1, and through SLAs with STFC-supported laboratories. This work was also supportedby the Fermi National Accelerator Laboratory, which is operated by the Fermi Research Alliance, under contract No. DE-AC02-76CH03000 with the U.S. Department of Energy, and by the U.S. National Science Foundation under grants PHY-0301737,PHY-0521313, PHY-0758173 and PHY-0630052. The authors also acknowledge the support of the World Premier International Research Center Initiative (WPI Initiative), MEXT, Japan

    Characterisation of the muon beams for the Muon Ionisation Cooling Experiment

    Get PDF
    A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.2–2.3 π mm-rad horizontally and 0.6–1.0 π mm-rad vertically, a horizontal dispersion of 90–190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE

    Strong constraints on the rare decays Bs -> mu+ mu- and B0 -> mu+ mu-

    Get PDF
    A search for Bs -> mu+ mu- and B0 -> mu+ mu- decays is performed using 1.0 fb^-1 of pp collision data collected at \sqrt{s}=7 TeV with the LHCb experiment at the Large Hadron Collider. For both decays the number of observed events is consistent with expectation from background and Standard Model signal predictions. Upper limits on the branching fractions are determined to be BR(Bs -> mu+ mu-) mu+ mu-) < 1.0 (0.81) x 10^-9 at 95% (90%) confidence level.Comment: 2+6 pages; 4 figures; Accepted for publication in Physical Review Letter

    First observation of Bs -> D_{s2}^{*+} X mu nu decays

    Get PDF
    Using data collected with the LHCb detector in proton-proton collisions at a centre-of-mass energy of 7 TeV, the semileptonic decays Bs -> Ds+ X mu nu and Bs -> D0 K+ X mu nu are detected. Two structures are observed in the D0 K+ mass spectrum at masses consistent with the known D^+_{s1}(2536) and $D^{*+}_{s2}(2573) mesons. The measured branching fractions relative to the total Bs semileptonic rate are B(Bs -> D_{s2}^{*+} X mu nu)/B(Bs -> X mu nu)= (3.3\pm 1.0\pm 0.4)%, and B(Bs -> D_{s1}^+ X munu)/B(Bs -> X mu nu)= (5.4\pm 1.2\pm 0.5)%, where the first uncertainty is statistical and the second is systematic. This is the first observation of the D_{s2}^{*+} state in Bs decays; we also measure its mass and width.Comment: 8 pages 2 figures. Published in Physics Letters

    MICE: The muon ionization cooling experiment. Step I: First measurement of emittance with particle physics detectors

    Get PDF
    Copyright @ 2011 APSThe Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.This work was supported by NSF grant PHY-0842798
    corecore