559 research outputs found

    Comment maintenir propres verres d'observation de chambres humides pom les priises de vue en accéléreré

    Get PDF
    The author examines different methods to avoid moisture condensation on observation windows caused by irregular temperature distribution. The respective measures consist of covering the window with a water-absorbent layer and heating with electrical current or through absorption of radiation. Furthermore, the culture-medium can be fixed in suitable cases on the observation window, through which photographs can be taken.L'auteur indique differentes methodes pour eviter les condensations d'humidite sur les verres d'observation provoquees par une repartition inegale des temperatures. On peut par exemple recouvrir le verre d'une couche susceptible de gontler, le chauffer par un courant electrique ou par l'absorption d'un rayonnement. On peut en outre, dans les cas qui s'y pretent, placer la couche nourriciere sur la verre d'observation et faire la prise de vue a travers

    Dispositifs simples de la prise de vue acceleree avee temps de pose variables

    Get PDF
    When filming in time-Iapse with low picture frequencies it is advantageous to work with an impuls method of operation, i. e. to switch in the camera for only a small proportion of the total time. The length of the exposure and the picture-frequency should be able to be regulated as independantly as possible from one another. The author discusses the possibilities given in this field and describes a suitable apparatus for the purpose.Pour des prises de vues a basse frequence d'images, il est interessant de travailler avec un dispositif a intermittences ; e. a. d. de faire fonctionner la camera seulement une fraction du temps total. Il est souhaitable de pouvoir regler independamment le temps dc pose et la frequence des images. L'auteur passe en revue les diverses possibilites et combinaisons offertes et donne un mode d'emploi

    Efficient implementation of a CCA2-secure variant of McEliece using generalized Srivastava codes

    No full text
    International audienceIn this paper we present efficient implementations of McEliece variants using quasi-dyadic codes. We provide secure parameters for a classical McEliece encryption scheme based on quasi-dyadic generalized Srivastava codes, and successively convert our scheme to a CCA2-secure protocol in the random oracle model applying the Fujisaki-Okamoto transform. In contrast with all other CCA2-secure code-based cryptosystems that work in the random oracle model, our conversion does not require a constant weight encoding function. We present results for both 128-bit and 80-bit security level, and for the latter we also feature an implementation for an embedded device

    Validation of coronary angiography-derived vessel fractional flow reserve in heart transplant patients with suspected graft vasculopathy

    Get PDF
    Cardiac transplant-related vasculopathy remains a leading cause of morbidity and mortality in heart transplant (HTx) recipients. Recently, coronary angiography-derived vessel fractional flow reserve (vFFR) has emerged as a new diagnostic computational tool to functionally evaluate the severity of coronary artery disease. Although vFFR estimates have been shown to perform well against invasive FFR in atherosclerotic coronary artery disease, data on the use of vFFR in heart transplant recipients suffering from cardiac transplant-related arteriopathy are lacking. The aim of the presented study was to validate coronary angiography-derived vessel fractional flow reserve to calculate fractional flow reserve in HTx patients with and without cardiac transplant-related vasculopathy. A prospective, single center study of HTx patients referred for annual check-up, undergoing surveillance coronarography was conducted. Invasive FFR was measured using a motorized device at the speed of 1.0 mm/s in all three major coronary arteries. Angiography-derived pullback FFR was derived from the angiogram and compared with invasive FFR pullback curve. Overall, 18,059 FFR values were extracted from the FFR pullback curves from 23 HTx patients. The mean age was 59.3 ± 9.7 years, the mean time after transplantation was 5.24 years [IQR 1.20, 11.25]. A total of 39 vessels from 23 patients (24 LAD, 11 LCX, 4 RCA) were analyzed. Mean distal vFFR was 0.87 ± 0.14 whereas invasive distal FFR was 0.88 ± 0.17. An excellent correlation was found between invasive distal FFR and vFFR (r = 0.92; p < 0.001). The correlation of the pullback tracing was high, with a correlation coefficient between vFFR and invasive FFR pullback values of 0.72 (95% CI 0.71 to 0.73, p < 0.001). The mean difference between vFFR and invasive FFR pullback values was −0.01 with 0.06 of SD (limits of agreements −0.12 to 0.13). In HTx patients, coronary angiography-derived FFR correlates excellently with invasively measured wire-derived FFR. Therefore, angiography derived FFR could be used as a novel diagnostic tool to quantify the functional severity of graft vasculopathy

    Simplified Assessment of the Index of Microvascular Resistance

    Get PDF
    Background. To validate a simplified invasive method for the calculation of the index of microvascular resistance (IMR). Methods. This is a prospective, single-center study of patients with chronic coronary syndromes presenting with nonobstructive coronary artery disease. IMR was obtained using both intravenous (IV) adenosine and intracoronary (IC) papaverine. Each IMR measurement was obtained in duplicate. The primary objective was the agreement between IMR acquired using adenosine and papaverine. Secondary objectives include reproducibility of IMR and time required for the IMR measurement. Results. One hundred and sixteen IMR measurements were performed in 29 patients. The mean age was 68.8 ± 7.24 years, and 27.6% was diabetics. IMR values were similar between papaverine and adenosine (17.7 ± 7.26 and 20.1 ± 8.6, p=0.25; Passing-Bablok coefficient A 0.58, 95% CI -2.42 to 3.53; coefficient B 0.90, 95% CI -0.74 to 1.07). The reproducibility of IMR was excellent with both adenosine and papaverine (ICC 0.78, 95% CI 0.63 to 0.88 and ICC 0.93, 95% CI 0.87 to 0.97). The time needed for microvascular assessment was significantly shortened by the use of IC papaverine (3.23 (2.84, 3.78) mins vs. 5.48 (4.94, 7.09) mins, p<0.0001). Conclusion. IMR can be reliably measured using IC papaverine with similar results compared to intravenous infusion of adenosine with increased reproducibility and reduced procedural time. This approach simplifies the invasive assessment of the coronary microcirculation in the catheterization laboratory

    Review of the C-nat(n,gamma) cross section and criticality calculations of the graphite moderated reactor BR1

    Full text link
    A review of the experimental data for natC(n,c) and 12C(n,c) was made to identify the origin of the natC capture cross sections included in evaluated data libraries and to clarify differences observed in neutronic calculations for graphite moderated reactors using different libraries. The performance of the JEFF-3.1.2 and ENDF/B-VII.1 libraries was verified by comparing results of criticality calculations with experimental results obtained for the BR1 reactor. This reactor is an air-cooled reactor with graphite as moderator and is located at the Belgian Nuclear Research Centre SCK-CEN in Mol (Belgium). The results of this study confirm conclusions drawn from neutronic calculations of the High Temperature Engineering Test Reactor (HTTR) in Japan. Furthermore, both BR1 and HTTR calculations support the capture cross section of 12C at thermal energy which is recommended by Firestone and Révay. Additional criticality calculations were carried out in order to illustrate that the natC thermal capture cross section is important for systems with a large amount of graphite. The present study shows that only the evaluation carried out for JENDL-4.0 reflects the current status of the experimental data

    Time-of-flight and activation experiments on 147Pm and 171Tm for astrophysics

    Get PDF
    The neutron capture cross section of several key unstable isotopes acting as branching points in the s-process are crucial for stellar nucleosynthesis studies, but they are very challenging to measure due to the difficult production of sufficient sample material, the high activity of the resulting samples, and the actual (n,γ) measurement, for which high neutron fluxes and effective background rejection capabilities are required. As part of a new program to measure some of these important branching points, radioactive targets of 147Pm and 171Tm have been produced by irradiation of stable isotopes at the ILL high flux reactor. Neutron capture on 146Nd and 170Er at the reactor was followed by beta decay and the resulting matrix was purified via radiochemical separation at PSI. The radioactive targets have been used for time-of-flight measurements at the CERN n-TOF facility using the 19 and 185 m beam lines during 2014 and 2015. The capture cascades were detected using a set of four C6D6 scintillators, allowing to observe the associated neutron capture resonances. The results presented in this work are the first ever determination of the resonance capture cross section of 147Pm and 171Tm. Activation experiments on the same 147Pm and 171Tm targets with a high-intensity 30 keV quasi-Maxwellian flux of neutrons will be performed using the SARAF accelerator and the Liquid-Lithium Target (LiLiT) in order to extract the corresponding Maxwellian Average Cross Section (MACS). The status of these experiments and preliminary results will be presented and discussed as well

    High accuracy 234U(n,f) cross section in the resonance energy region

    Get PDF
    New results are presented of the 234U neutron-induced fission cross section, obtained with high accuracy in the resonance region by means of two methods using the 235U(n,f) as reference. The recent evaluation of the 235U(n,f) obtained with SAMMY by L. C. Leal et al. (these Proceedings), based on previous n-TOF data [1], has been used to calculate the 234U(n,f) cross section through the 234U/235U ratio, being here compared with the results obtained by using the n-TOF neutron flux

    Characterization of the n-TOF EAR-2 neutron beam

    Get PDF
    The experimental area 2 (EAR-2) at CERNs neutron time-of-flight facility (n-TOF), which is operational since 2014, is designed and built as a short-distance complement to the experimental area 1 (EAR-1). The Parallel Plate Avalanche Counter (PPAC) monitor experiment was performed to characterize the beam prole and the shape of the neutron 'ux at EAR-2. The prompt γ-flash which is used for calibrating the time-of-flight at EAR-1 is not seen by PPAC at EAR-2, shedding light on the physical origin of this γ-flash

    Development of a novel segmented mesh MicroMegas detector for neutron beam profiling

    Get PDF
    A novel MicroMegas detector based on microbulk technology with an embedded XY strip structure was developed, obtained by segmenting both the mesh and the anode in perpendicular directions. This results in a very low-mass device with good energy and spatial resolution capabilities. Such a detector is practically “transparent” to neutrons, being ideal for in-beam neutron measurements and can be used as a quasi-online neutron beam profiler at neutron time-of-flight facilities. A dedicated front end electronics and acquisition system has been developed and used. The first studies of this new detection system are presented and discussed
    corecore