615 research outputs found
Gluon fusion contribution to W+W- + jet production
We describe the computation of the process that contributes
to the production of two -bosons and a jet at the CERN Large Hadron Collider
(LHC). While formally of next-to-next-to-leading order (NNLO) in QCD, this
process can be evaluated separately from the bulk of NNLO QCD corrections
because it is finite and gauge-invariant. It is also enhanced by the large
gluon flux and by selection cuts employed in the Higgs boson searches in the
decay channel , as was first pointed out by Binoth {\it et al.}
in the context of production. For cuts employed by the ATLAS
collaboration, we find that the gluon fusion contribution to
enhances the background by about ten percent and can lead to moderate
distortions of kinematic distributions which are instrumental for the ongoing
Higgs boson searches at the LHC. We also release a public code to compute the
NLO QCD corrections to this process, in the form of an add-on to the package
{\tt MCFM}.Comment: 13 pages, 4 figures, 3 table
Dielectric and thermal relaxation in the energy landscape
We derive an energy landscape interpretation of dielectric relaxation times
in undercooled liquids, comparing it to the traditional Debye and
Gemant-DiMarzio-Bishop pictures. The interaction between different local
structural rearrangements in the energy landscape explains qualitatively the
recently observed splitting of the flow process into an initial and a final
stage. The initial mechanical relaxation stage is attributed to hopping
processes, the final thermal or structural relaxation stage to the decay of the
local double-well potentials. The energy landscape concept provides an
explanation for the equality of thermal and dielectric relaxation times. The
equality itself is once more demonstrated on the basis of literature data for
salol.Comment: 7 pages, 3 figures, 41 references, Workshop Disordered Systems,
Molveno 2006, submitted to Philosophical Magazin
Automation of one-loop QCD corrections
We present the complete automation of the computation of one-loop QCD
corrections, including UV renormalization, to an arbitrary scattering process
in the Standard Model. This is achieved by embedding the OPP integrand
reduction technique, as implemented in CutTools, into the MadGraph framework.
By interfacing the tool so constructed, which we dub MadLoop, with MadFKS, the
fully automatic computation of any infrared-safe observable at the
next-to-leading order in QCD is attained. We demonstrate the flexibility and
the reach of our method by calculating the production rates for a variety of
processes at the 7 TeV LHC.Comment: 64 pages, 12 figures. Corrected the value of m_Z in table 1. In table
2, corrected the values of cross sections in a.4 and a.5 (previously computed
with mu=mtop/2 rather than mu=mtop/4). In table 2, corrected the values of
NLO cross sections in b.3, b.6, c.3, and e.7 (the symmetry factor for a few
virtual channels was incorrect). In sect. A.4.3, the labeling of the
four-momenta was incorrec
Scattering AMplitudes from Unitarity-based Reduction Algorithm at the Integrand-level
SAMURAI is a tool for the automated numerical evaluation of one-loop
corrections to any scattering amplitudes within the dimensional-regularization
scheme. It is based on the decomposition of the integrand according to the
OPP-approach, extended to accommodate an implementation of the generalized
d-dimensional unitarity-cuts technique, and uses a polynomial interpolation
exploiting the Discrete Fourier Transform. SAMURAI can process integrands
written either as numerator of Feynman diagrams or as product of tree-level
amplitudes. We discuss some applications, among which the 6- and 8-photon
scattering in QED, and the 6-quark scattering in QCD. SAMURAI has been
implemented as a Fortran90 library, publicly available, and it could be a
useful module for the systematic evaluation of the virtual corrections oriented
towards automating next-to-leading order calculations relevant for the LHC
phenomenology.Comment: 35 pages, 7 figure
Hepta-Cuts of Two-Loop Scattering Amplitudes
We present a method for the computation of hepta-cuts of two loop scattering
amplitudes. Four dimensional unitarity cuts are used to factorise the integrand
onto the product of six tree-level amplitudes evaluated at complex momentum
values. Using Gram matrix constraints we derive a general parameterisation of
the integrand which can be computed using polynomial fitting techniques. The
resulting expression is further reduced to master integrals using conventional
integration by parts methods. We consider both planar and non-planar topologies
for 2 to 2 scattering processes and apply the method to compute hepta-cut
contributions to gluon-gluon scattering in Yang-Mills theory with adjoint
fermions and scalars.Comment: 37 pages, 6 figures. version 2 : minor updates, published versio
Anatomical-Molecular Distribution of EphrinA1 in Infarcted Mouse Heart Using MALDI Mass Spectrometry Imaging
EphrinA1 is a tyrosine kinase receptor localized in the cellular membrane of healthy cardiomyocytes, the expression of which is lost upon myocardial infarction (MI). Intra-cardiac injection of the recombinant form of ephrinA1 (ephrinA1-Fc) at the time of ligation in mice has shown beneficial effects by reducing infarct size and myocardial necrosis post-MI. To date, immunohistochemistry and Western blotting comprise the only experimental approaches utilized to localize and quantify relative changes of ephrinA1 in sections and homogenates of whole left ventricle, respectively. Herein, we used matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI-MSI) coupled with a time-of-flight mass spectrometer (MALDI/TOF MS) to identify intact as well as tryptic fragments of ephrinA1 in healthy controls and acutely infarcted murine hearts. The purpose of the present study was 3-fold: (1) to spatially resolve the molecular distribution of endogenous ephrinA1, (2) to determine the anatomical expression profile of endogenous ephrinA1 after acute MI, and (3) to identify molecular targets of ephrinA1-Fc action post-MI. The tryptic fragments detected were identified as the ephrinA1-isoform with 38% and 34% sequence coverage and Mascot scores of 25 for the control and MI hearts, respectively. By using MALDI-MSI, we have been able to simultaneously measure the distribution and spatial localization of ephrinA1, as well as additional cardiac proteins, thus offering valuable information for the elucidation of molecular partners, mediators, and targets of ephrinA1 action in cardiac muscle.Open Access Fun
Co-prescription of medication for bipolar disorder and diabetes mellitus : a nationwide population based study with focus on gender differences
BackgroundStudies have shown a correlation between bipolar disorder and diabetes mellitus. It is unclear if this correlation is a part of common pathophysiological pathways, or if medication for bipolar disorder has negative effects on blood sugar regulation.MethodsThe Norwegian prescription database was analyzed. Prescriptions for lithium, lamotrigine, carbamazepine and valproate were used as proxies for bipolar disorder. Prescriptions for insulin and oral anti-diabetic agents were used as proxies for diabetes mellitus. We explored the association between medication for bipolar disorder and diabetes medication by logistic regressionResultsWe found a strong association between concomitant use of medication to treat diabetes mellitus and mood stabilizers for the treatment of bipolar disorder. Females had a 30% higher risk compared to men of being treated for both disorders. Persons using oral anti-diabetic agents had higher odds of receiving valproate than either lithium or lamotrigine. Use of insulin as monotherapy seemed to have lower odds than oral anti-diabetic agents of co-prescription of mood stabilizers, compared to the general population.ConclusionsThis study showed a strong association between the use of mood stabilizers and anti-diabetic agents. The association was stronger among women than men
Recommended from our members
The Views of Mental Health Manager Towards the Use of a Family Work Model for Psychosis in Guangzhou, China
Family Interventions in Psychosis (FIP) have been promoted internationally but have been criticised for being based on western cultural models. This paper reports on a focus group study with 10 Integrated Mental Health Service Managers in Guangzhou, China using thematic analysis. Managers believed FIP might benefit families but identified potential difficulties due to (a) families avoiding services due to the ‘shame’ of mental illness (b) unrealistic expectations of services amongst families (c) deferral to ‘key decision-makers’ within families when discussing family issues with workers. The findings indicate that FIP work should focus on interaction between carers in the first instance with service users being introduced into sessions at a later date and that more attention needs to be given by the research community to how FIP may be adapted to cultural norms within China
Coronary MR angiography at 3T: fat suppression versus water-fat separation
Objectives: To compare Dixon water-fat suppression with spectral pre-saturation with inversion recovery (SPIR) at 3T for coronary magnetic resonance angiography (MRA) and to demonstrate the feasibility of fat suppressed coronary MRA at 3T without administration of a contrast agent. Materials and methods: Coronary MRA with Dixon water-fat separation or with SPIR fat suppression was compared on a 3T scanner equipped with a 32-channel cardiac receiver coil. Eight healthy volunteers were examined. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), right coronary artery (RCA), and left anterior descending (LAD) coronary artery sharpness and length were measured and statistically compared. Two experienced cardiologists graded the visual image quality of reformatted Dixon and SPIR images (1: poor quality to 5: excellent quality). Results: Coronary MRA images in healthy volunteers showed improved contrast with the Dixon technique compared to SPIR (CNR blood-fat: Dixon = 14.9 ± 2.9 and SPIR = 13.9 ± 2.1; p = 0.08, CNR blood-myocardium: Dixon = 10.2 ± 2.7 and SPIR = 9.11 ± 2.6; p = 0.1). The Dixon method led to similar fat suppression (fat SNR with Dixon: 2.1 ± 0.5 vs. SPIR: 2.4 ± 1.2, p = 0.3), but resulted in significantly increased SNR of blood (blood SNR with Dixon: 19.9 ± 4.5 vs. SPIR: 15.5 ± 3.1, p < 0.05). This means the residual fat signal is slightly lower with the Dixon compared to the SIPR technique (although not significant), while the SNR of blood is significantly higher with the Dixon technique. Vessel sharpness of the RCA was similar for Dixon and SPIR (57 ± 7 % vs. 56 ± 9 %, p = 0.2), while the RCA visualized vessel length was increased compared to SPIR fat suppression (107 ± 21 vs. 101 ± 21 mm, p < 0.001). For the LAD, vessel sharpness (50 ± 13 % vs. 50 ± 7 %, p = 0.4) and vessel length (92 ± 46 vs. 90 ± 47 mm, p = 0.4) were similar with both techniques. Consequently, the Dixon technique resulted in an improved visual score of the coronary arteries in the water fat separated images of healthy subjects (RCA: 4.6 ± 0.5 vs. 4.1 ± 0.7, p = 0.01, LAD: 4.1 ± 0.7 vs. 3.5 ± 0.8, p = 0.007). Conclusions: Dixon water-fat separation can significantly improve coronary artery image quality without the use of a contrast agent at 3T
Feasibility of MR-Based Body Composition Analysis in Large Scale Population Studies
Introduction
Quantitative and accurate measurements of fat and muscle in the body are important for prevention and diagnosis of diseases related to obesity and muscle degeneration. Manually segmenting muscle and fat compartments in MR body-images is laborious and time-consuming, hindering implementation in large cohorts. In the present study, the feasibility and success-rate of a Dixon-based MR scan followed by an intensity-normalised, non-rigid, multi-atlas based segmentation was investigated in a cohort of 3,000 subjects.
Materials and Methods
3,000 participants in the in-depth phenotyping arm of the UK Biobank imaging study underwent a comprehensive MR examination. All subjects were scanned using a 1.5 T MR-scanner with the dual-echo Dixon Vibe protocol, covering neck to knees. Subjects were scanned with six slabs in supine position, without localizer. Automated body composition analysis was performed using the AMRA Profilerâ„¢ system, to segment and quantify visceral adipose tissue (VAT), abdominal subcutaneous adipose tissue (ASAT) and thigh muscles. Technical quality assurance was performed and a standard set of acceptance/rejection criteria was established. Descriptive statistics were calculated for all volume measurements and quality assurance metrics.
Results
Of the 3,000 subjects, 2,995 (99.83%) were analysable for body fat, 2,828 (94.27%) were analysable when body fat and one thigh was included, and 2,775 (92.50%) were fully analysable for body fat and both thigh muscles. Reasons for not being able to analyse datasets were mainly due to missing slabs in the acquisition, or patient positioned so that large parts of the volume was outside of the field-of-view.
Discussion and Conclusions
In conclusion, this study showed that the rapid UK Biobank MR-protocol was well tolerated by most subjects and sufficiently robust to achieve very high success-rate for body composition analysis. This research has been conducted using the UK Biobank Resource
- …