95 research outputs found

    Gravimetrically prepared carbon dioxide standards in support of atmospheric research

    Get PDF
    We have explored a one-step method for gravimetric preparation of CO2-in-air standards in aluminum cylinders. We consider both adsorption to stainless steel surfaces used in the transfer of highly pure CO2 and adsorption of CO2 to cylinder walls. We demonstrate that CO2-in-air standards can be prepared with relatively low uncertainty (∼&thinsp;0.04&thinsp;%, ∼95&thinsp;% confidence level) by introducing aliquots whose masses are known to high precision and by using well-characterized cylinders. Five gravimetric standards, prepared over the nominal range of 350 to 490&thinsp;µmol mol−1 (parts per million,&thinsp;ppm), showed excellent internal consistency, with residuals from a linear fit equal to 0.05&thinsp;ppm. This work compliments efforts to maintain the World Meteorological Organization, Global Atmosphere Watch, mole fraction scale for carbon dioxide in air, widely used for atmospheric monitoring. This gravimetric technique could be extended to other atmospheric trace gases, depending on the vapor pressure of the gas.</p

    Evaluation of a field-deployable Nafion (TM)-based air-drying system for collecting whole air samples and its application to stable isotope measurements of CO2

    Get PDF
    Atmospheric flask samples are either collected at atmospheric pressure by opening a valve of a pre-evacuated flask or pressurized with the help of a pump to a few bar above ambient pressure. Under humid conditions, there is a risk that water vapor in the sample leads to condensation on the walls of the flask, notably at higher than ambient sampling pressures. Liquid water in sample flasks is known to affect the CO2 mixing ratios and also alters the isotopic composition of oxygen (17O and 18O) in CO2 via isotopic equilibration. Hence, for accurate determination of CO2 mole fractions and its stable isotopic composition, it is vital to dry the air samples to a sufficiently low dew point before they are pressurized in flasks to avoid condensation. Moreover, the drying system itself should not influence the mixing ratio and the isotopic composition of CO2 or that of the other constituents under study. For the Airborne Stable Isotopes of Carbon from the Amazon (ASICA) project focusing on accurate measurements of CO2 and its singly substituted stable isotopologues over the Amazon, an air-drying system capable of removing water vapor from air sampled at a dew point lower than -2 °C, flow rates up to 12 L min-1 and without the need for electrical power was needed. Since to date no commercial air-drying device that meets these requirements has been available, we designed and built our own consumable-free, power-free and portable drying system based on multitube Nafion™ gas sample driers (Perma Pure, Lakewood, USA). The required dry purge air is provided by feeding the exhaust flow of the flask sampling system through a dry molecular sieve (type 3A) cartridge. In this study we describe the systematic evaluation of our Nafion™-based air sample dryer with emphasis on its performance concerning the measurements of atmospheric CO2 mole fractions and the three singly substituted isotopologues of CO2 (16O13C16O, 16O12C17O and 16O12C18O), as well as the trace gas species CH4, CO, N2O and SF6. Experimental results simulating extreme tropical conditions (saturated air at 33 °C) indicated that the response of the air dryer is almost instantaneous and that approximately 85 L of air, containing up to 4 % water vapor, can be processed staying below a -2 °C dew point temperature (at 275 kPa). We estimated that at least eight flasks can be sampled (at an overpressure of 275 kPa) with a water vapor content below -2 °C dew point temperature during a typical flight sampling up to 5 km altitude over the Amazon, whereas the remaining samples would stay well below 5 °C dew point temperature (at 275 kPa). The performance of the air dryer on measurements of CO2, CH4, CO, N2O, and SF6 and the CO2 isotopologues 16O13C16O and 16O12C18O was tested in the laboratory simulating real sampling conditions by compressing humidified air from a calibrated cylinder, after being dried by the air dryer, into sample flasks. We found that the mole fraction and the isotopic composition difference between the different test conditions (including the dryer) and the base condition (dry air, without dryer) remained well within or very close to, in the case of N2O, the World Meteorological Organization recommended compatibility goals for independent measurement programs, proving that the test condition induced no significant bias on the sample measurements

    Making connections: technological interventions to support students in using, and tutors in creating, assessment feedback

    Get PDF
    This paper explores the potential of technology to enhance the assessment and feedback process for both staff and students. The ‘Making Connections’ project aimed to better understand the connections that students make between the feedback that they receive and future assignments, and explored whether technology can help them in this activity. The project interviewed 10 tutors and 20 students, using a semi-structured approach. Data were analysed using a thematic approach, and the findings have identified a number of areas in which improvements could be made to the assessment and feedback process through the use of technology. The findings of the study cover each stage of the assessment process from the perspective of both staff and students. The findings are discussed in the context of current literature, and special attention is given to projects from the UK higher education sector intended to address the same issues. Keywords: feed-forward; assessment; practices; technology; technology-enhanced learnin

    The state of the Martian climate

    Get PDF
    60°N was +2.0°C, relative to the 1981–2010 average value (Fig. 5.1). This marks a new high for the record. The average annual surface air temperature (SAT) anomaly for 2016 for land stations north of starting in 1900, and is a significant increase over the previous highest value of +1.2°C, which was observed in 2007, 2011, and 2015. Average global annual temperatures also showed record values in 2015 and 2016. Currently, the Arctic is warming at more than twice the rate of lower latitudes

    Hydrous upwelling across the mantle transition zone beneath the Afar Triple Junction

    Get PDF
    The mechanisms that drive the upwelling of chemical heterogeneity from the lower to upper mantle (e.g., thermal versus compositional buoyancy) are key to our understanding of whole mantle con- vective processes. We address these issues through a receiver function study on new seismic data from recent deployments located on the Afar Triple Junction, a location associated with deep mantle upwelling. The detailed images of upper mantle and mantle transition zone structure illuminate features that give insights into the nature of upwelling from the deep Earth. A seismic low-velocity layer directly above the mantle transition zone, interpreted as a stable melt layer, along with a prominent 520 km discontinuity sug- gest the presence of a hydrous upwelling. A relatively uniform transition zone thickness across the region suggests a weak thermal anomaly (<100 K) may be present and that upwelling must be at least partly driven by compositional buoyancy. The results suggest that the lower mantle is a source of volatile rich, chemically distinct upwellings that influence the structure of the upper mantle, and potentially the chemis- try of surface lavas
    corecore