339 research outputs found
Calibration and performance tests of the Very-Front-End electronics for the CMS electromagnetic calorimeter
The Very-Front-End electronics processing signals from photodetectors of the CMS electromagnetic calorimeter have been put through an extensive test programme to guarantee functionality and reliability. The final characteristics of the VFE boards designed for the calorimeter barrel and endcaps are presented. The results, which have been also verified during test beam at CERN, confirm the high quality of the boards production and show that the CMS detector specifications are reached
Performance of Glass Resistive Plate Chambers for a high granularity semi-digital calorimeter
A new design of highly granular hadronic calorimeter using Glass Resistive
Plate Chambers (GRPCs) with embedded electronics has been proposed for the
future International Linear Collider (ILC) experiments. It features a 2-bit
threshold semi-digital read-out. Several GRPC prototypes with their electronics
have been successfully built and tested in pion beams. The design of these
detectors is presented along with the test results on efficiency, pad
multiplicity, stability and reproducibility.Comment: 16 pages, 15 figure
Construction and commissioning of a technological prototype of a high-granularity semi-digital hadronic calorimeter
A large prototype of 1.3m3 was designed and built as a demonstrator of the
semi-digital hadronic calorimeter (SDHCAL) concept proposed for the future ILC
experiments. The prototype is a sampling hadronic calorimeter of 48 units. Each
unit is built of an active layer made of 1m2 Glass Resistive Plate
Chamber(GRPC) detector placed inside a cassette whose walls are made of
stainless steel. The cassette contains also the electronics used to read out
the GRPC detector. The lateral granularity of the active layer is provided by
the electronics pick-up pads of 1cm2 each. The cassettes are inserted into a
self-supporting mechanical structure built also of stainless steel plates
which, with the cassettes walls, play the role of the absorber. The prototype
was designed to be very compact and important efforts were made to minimize the
number of services cables to optimize the efficiency of the Particle Flow
Algorithm techniques to be used in the future ILC experiments. The different
components of the SDHCAL prototype were studied individually and strict
criteria were applied for the final selection of these components. Basic
calibration procedures were performed after the prototype assembling. The
prototype is the first of a series of new-generation detectors equipped with a
power-pulsing mode intended to reduce the power consumption of this highly
granular detector. A dedicated acquisition system was developed to deal with
the output of more than 440000 electronics channels in both trigger and
triggerless modes. After its completion in 2011, the prototype was commissioned
using cosmic rays and particles beams at CERN.Comment: 49 pages, 41 figure
First test of a power-pulsed electronics system on a GRPC detector in a 3-Tesla magnetic field
An important technological step towards the realization of an ultra-granular
hadronic calorimeter to be used in the future International Linear Collider
(ILC) experiments has been made. A 33X50 cm2 GRPC detector equipped with a
power-pulsed electronics board offering a 1cm2 lateral segmentation was
successfully tested in a 3-Tesla magnet operating at the H2 beam line of the
CERN SPS. An important reduction of power consumption with no deterioration of
the detector performance is obtained when the power-pulsing mode is applied.
This important result shows that ultra-granular calorimeters for ILC
experiments are not only an attractive but also a realistic option.Comment: 10 pages, 9 figure
Influence of segmental chromosome abnormalities on survival in children over the age of 12 months with unresectable localised peripheral neuroblastic tumours without MYCN amplification.
BACKGROUND: The prognostic impact of segmental chromosome alterations (SCAs) in children older than 1 year, diagnosed with localised unresectable neuroblastoma (NB) without MYCN amplification enrolled in the European Unresectable Neuroblastoma (EUNB) protocol is still to be clarified, while, for other group of patients, the presence of SCAs is associated with poor prognosis.
METHODS: To understand the role of SCAs we performed multilocus/pangenomic analysis of 98 tumour samples from patients enrolled in the EUNB protocol.
RESULTS: Age at diagnosis was categorised into two groups using 18 months as the age cutoff. Significant difference in the presence of SCAs was seen in tumours of patients between 12 and 18 months and over 18 months of age at diagnosis, respectively (P=0.04). A significant correlation (P=0.03) was observed between number of SCAs per tumour and age. Event-free (EFS) and overall survival (OS) were calculated in both age groups, according to both the presence and number of SCAs. In older patients, a poorer survival was associated with the presence of SCAs (EFS=46% vs 75%, P=0.023; OS=66.8% vs 100%, P=0.003). Moreover, OS of older patients inversely correlated with number of SCAs (P=0.002). Finally, SCAs provided additional prognostic information beyond histoprognosis, as their presence was associated with poorer OS in patients over 18 months with unfavourable International Neuroblastoma Pathology Classification (INPC) histopathology (P=0.018).
CONCLUSIONS: The presence of SCAs is a negative prognostic marker that impairs outcome of patients over the age of 18 months with localised unresectable NB without MYCN amplification, especially when more than one SCA is present. Moreover, in older patients with unfavourable INPC tumour histoprognosis, the presence of SCAs significantly affects OS
High rate, fast timing Glass RPC for the high {\eta} CMS muon detectors
The HL-LHC phase is designed to increase by an order of magnitude the amount
of data to be collected by the LHC experiments. To achieve this goal in a
reasonable time scale the instantaneous luminosity would also increase by an
order of magnitude up to . The region of the forward
muon spectrometer () is not equipped with RPC stations. The
increase of the expected particles rate up to (including a
safety factor 3) motivates the installation of RPC chambers to guarantee
redundancy with the CSC chambers already present. The actual RPC technology of
CMS cannot sustain the expected background level. The new technology that will
be chosen should have a high rate capability and provides a good spatial and
timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity
(LR) glass is proposed to equip at least the two most far away of the four high
muon stations of CMS. First the design of small size prototypes and
studies of their performance in high-rate particles flux is presented. Then the
proposed designs for large size chambers and their fast-timing electronic
readout are examined and preliminary results are provided.Comment: 14 pages, 11 figures, Conference proceeding for the 2016 Resistive
Plate Chambers and Related Detector
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
The spatial development of hadronic showers in the CALICE scintillator-steel
analogue hadron calorimeter is studied using test beam data collected at CERN
and FNAL for single positive pions and protons with initial momenta in the
range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron
showers are parametrised with two-component functions. The parametrisation is
fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics
lists from Geant4 version 9.6. The parameters extracted from data and simulated
samples are compared for the two types of hadrons. The response to pions and
the ratio of the non-electromagnetic to the electromagnetic calorimeter
response, h/e, are estimated using the extrapolation and decomposition of the
longitudinal profiles.Comment: 38 pages, 19 figures, 5 tables; author list changed; submitted to
JINS
Characterisation of spin coated engineered <i>Escherichia coli</i> biofilms using atomic force microscopy
The ability of biofilms to withstand chemical and physical extremes gives them the potential to be developed as robust biocatalysts. Critical to this issue is their capacity to withstand the physical environment within a bioreactor; in order to assess this capability knowledge of their surface properties and adhesive strength is required. Novel atomic force microscopy experiments conducted under growth conditions (30° C) were used to characterise Escherichia coli biofilms, which were generated by a recently developed spin-coating method onto a poly-L-lysine coated glass substrate. High-resolution topographical images were obtained throughout the course of biofilm development, quantifying the tip-cell interaction force during the 10 day maturation process. Strikingly, the adhesion force between the Si AFM tip and the biofilm surface increased from 0.8 nN to 40 nN within 3 days. This was most likely due to the production of extracellular polymer substance (EPS), over the maturation period, which was also observed by electron microscopy. At later stages of maturation, multiple retraction events were also identified corresponding to biofilm surface features thought to be EPS components. The spin coated biofilms were shown to have stronger surface adhesion than an equivalent conventionally grown biofilm on the same glass substrate
Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up
Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
A first prototype of a scintillator strip-based electromagnetic calorimeter
was built, consisting of 26 layers of tungsten absorber plates interleaved with
planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a
positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's
performance is presented in terms of the linearity and resolution of the energy
measurement. These results represent an important milestone in the development
of highly granular calorimeters using scintillator strip technology. This
technology is being developed for a future linear collider experiment, aiming
at the precise measurement of jet energies using particle flow techniques
- …