832 research outputs found
TEM10 homodyne detection as an optimal small displacement and tilt measurements scheme
We report an experimental demonstration of optimal measurements of small
displacement and tilt of a Gaussian beam - two conjugate variables - involving
a homodyne detection with a TEM10 local oscillator. We verify that the standard
split detection is only 64% efficient. We also show a displacement measurement
beyond the quantum noise limit, using a squeezed vacuum TEM10 mode within the
input beam.Comment: 9 pages, 8 figure
Quantum measurements of spatial conjugate variables: Displacement and tilt of a Gaussian beam
We consider the problem of measurement of optical transverse profile
parameters and their conjugate variable. Using multi-mode analysis, we
introduce the concept of detection noise-modes. For Gaussian beams,
displacement and tilt are a pair of transverse profile conjugate variables. We
experimentally demonstrate their optimal encoding and detection with a spatial
homodyning scheme. Using higher order spatial mode squeezing, we show the
sub-shot noise measurements for the displacement and tilt of a Gaussian beam.Comment: 3 page
Quantum cascade laser-based reflectance spectroscopy: a robust approach for the classification of plastic type
© The Author(s), 2020. This article is distributed under the terms of the Creative Commons Attribution License. The definitive version was published in Michel, A. P. M., Morrison, A. E., Colson, B. C., Pardis, W. A., Moya, X. A., Harb, C. C., & White, H. K. Quantum cascade laser-based reflectance spectroscopy: a robust approach for the classification of plastic type. Optics Express, 28(12), (2020): 17741-17756, doi:10.1364/OE.393231.The identification of plastic type is important for environmental applications ranging from recycling to understanding the fate of plastics in marine, atmospheric, and terrestrial environments. Infrared reflectance spectroscopy is a powerful approach for plastics identification, requiring only optical access to a sample. The use of visible and near-infrared wavelengths for plastics identification are limiting as dark colored plastics absorb at these wavelengths, producing no reflectance spectra. The use of mid-infrared wavelengths instead enables dark plastics to be identified. Here we demonstrate the capability to utilize a pulsed, widely-tunable (5.59 - 7.41 µm) mid-infrared quantum cascade laser, as the source for reflectance spectroscopy, for the rapid and robust identification of plastics. Through the application of linear discriminant analysis to the resulting spectral data set, we demonstrate that we can correctly classify five plastic types: polyethylene terephthalate (PET), high density polyethylene (HDPE), low density polyethylene (LDPE), polypropylene (PP), and polystyrene (PS), with a 97% accuracy rate.Richard Saltonstall Charitable Foundation; National Academies Keck Futures Initiative (NAKFI DBS13)
Intensity noise of injection-locked lasers: Quantum theory using a linearized input-output method
We derive analytical expressions for the quantum-noise spectra of an atomic laser using a linearized input-output method. We generalize the method to the problem of injection-locked lasers. We identify three distinct spectral noise regimes in the solution, unifying previous results. The approach offers insights into the physical processes and is especially suited for comparison with experiment. The quantum spectral noise properties of the pump laser and the injected laser appear explicitly in the solution
Fermi-LAT Search for Pulsar Wind Nebulae around gamma-ray Pulsars
The high sensitivity of the Fermi-LAT (Large Area Telescope) offers the first
opportunity to study faint and extended GeV sources such as pulsar wind nebulae
(PWNe). After one year of observation the LAT detected and identified three
pulsar wind nebulae: the Crab Nebula, Vela-X and the PWN inside MSH 15-52. In
the meantime, the list of LAT detected pulsars increased steadily. These
pulsars are characterized by high energy loss rates from ~3 \times 10^{33} erg
s to 5 \times 10 erg s and are therefore likely to power a
PWN. This paper summarizes the search for PWNe in the off-pulse windows of 54
LAT-detected pulsars using 16 months of survey observations. Ten sources show
significant emission, seven of these likely being of magnetospheric origin. The
detection of significant emission in the off-pulse interval offers new
constraints on the gamma-ray emitting regions in pulsar magnetospheres. The
three other sources with significant emission are the Crab Nebula, Vela-X and a
new pulsar wind nebula candidate associated with the LAT pulsar PSR J1023-5746,
coincident with the TeV source HESS J1023-575. We further explore the
association between the H.E.S.S. and the Fermi source by modeling its spectral
energy distribution. Flux upper limits derived for the 44 remaining sources are
used to provide new constraints on famous PWNe that have been detected at keV
and/or TeV energies.Comment: Accepted for publication in Astrophysical Journal, 42 pages, 17
figure
TriTrypDB: a functional genomic resource for the Trypanosomatidae
TriTrypDB (http://tritrypdb.org) is an integrated database providing access to genome-scale datasets for kinetoplastid parasites, and supporting a variety of complex queries driven by research and development needs. TriTrypDB is a collaborative project, utilizing the GUS/WDK computational infrastructure developed by the Eukaryotic Pathogen Bioinformatics Resource Center (EuPathDB.org) to integrate genome annotation and analyses from GeneDB and elsewhere with a wide variety of functional genomics datasets made available by members of the global research community, often pre-publication. Currently, TriTrypDB integrates datasets from Leishmania braziliensis, L. infantum, L. major, L. tarentolae, Trypanosoma brucei and T. cruzi. Users may examine individual genes or chromosomal spans in their genomic context, including syntenic alignments with other kinetoplastid organisms. Data within TriTrypDB can be interrogated utilizing a sophisticated search strategy system that enables a user to construct complex queries combining multiple data types. All search strategies are stored, allowing future access and integrated searches. ‘User Comments’ may be added to any gene page, enhancing available annotation; such comments become immediately searchable via the text search, and are forwarded to curators for incorporation into the reference annotation when appropriate
Test beam performance measurements for the Phase I upgrade of the CMS pixel detector
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is (99.95 ± 0.05) %, while the intrinsic spatial resolutions are (4.80 ± 0.25) μm and (7.99 ± 0.21) μm along the 100 μm and 150 μm pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.Peer reviewe
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to neq/cm. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations
- …