329 research outputs found
Low temperature degradation behaviour of 10Ce-TZP/Al2O3 bioceramics obtained by microwave sintering technology
Zirconia is one of the most used ceramics, especially for biomedical applications, due to its exceptional mechanical properties. However, it is commonly known that its properties can be diminished owing to a low temperature degradation (LTD). This phenomenon consists on a spontaneous phase transformation, from tetragonal to monoclinic, under certain conditions, which is accelerated when the samples are exposed under high levels of humidity at a temperature range between 20-300 ÂșC. In addition to the fact that the monoclinic phase presents worse mechanical properties than the tetragonal one, there is a volume change of 4% between phases that gives rise to defects in the material as microcracks. Due to this reason, zirconia prostheses failed catastrophically inside the human body between 1999 and 2001 (1). Previous researches reveal that Al2O3 addition suppress the propagation of phase transformation (2). Thus, the aim of the present work is to study the hydrothermal ageing of zirconia doped with ceria and toughened with alumina (10Ce-TZP/Al2O3) composite, which has been sintered by microwave employing two different frequencies: 2.45 and 5.8 GHz. Microwave heating technology is based on the absorption of electromagnetic radiation by the material, which allows the sample to be heated. So far, most microwave heating equipments use 2.45 GHz; accordingly, the novelty of this study is to employ a frequency of 5.8 GHz and to investigate its effect on LTD. LTD is carried out in an autoclaved in steam at 120 ÂșC and 1.2 bar, because these conditions accelerate the hydrothermal aging process (3). In order to characterize the degraded samples, micro-Raman spectroscopy, AFM, nanoindentation technique and electronic microscopy have been performed.
References
1. Norton, M. R., Yarlagadda, R., Anderson, G. H. J. Bone Joint Surg. Br., 2002, 84âB, 631â635.
2. Fabbri, P., Piconi, C., Burresi, E., Magnani, G., Mazzanti, F., Mingazzini, C. Dent. Mater., 2014.
3. Presenda, Ă., Salvador, M. D., Moreno, R., Borrell, A. J. Am. Ceram. Soc., 2015, 98, 3680â3689
The impact of chorionicity on pregnancy outcome and neurodevelopment at 2 years old among twins born preterm: the EPIPAGE-2 cohort study
OBJECTIVE
To compare the shortâ and midâterm outcomes of preterm twins by chorionicity of pregnancy.
DESIGN
Prospective nationwide populationâbased EPIPAGEâ2 cohort study.
SETTING
546 maternity units in France, between March and December 2011.
POPULATION
A total of 1700 twin neonates born between 24 and 34 weeks of gestation.
METHODS
The association of chorionicity with outcomes was analysed using multivariate regression models.
MAIN OUTCOME MEASURES
First, survival at 2âyear corrected age with or without neurosensory impairment, and second, perinatal, shortâ, and midâterm outcomes (survival at discharge, survival at discharge without severe morbidity) were described and compared by chorionicity.
RESULTS
In the EPIPAGE 2 cohort, 1700 preterm births were included (850 twin pregnancies). In all, 1220 (71.8%) were from dichorionic (DC) pregnancies and 480 from monochorionic (MC) pregnancies. MC pregnancies had three times more medical terminations than DC pregnancies (1.67 versus 0.51%, P < 0.001), whereas there were three times more stillbirths in MC than in DC pregnancies (10.09 versus 3.78%, P < 0.001). Both twins were alive at birth in 86.6% of DC pregnancies compared with 80.0% among MC pregnancies (P = 0.008). No significant difference according to chorionicity was found regarding neonatal deaths and morbidities. Likewise, for children born earlier than 32 weeks, the 2âyear followâup neurodevelopmental results were not significantly different between DC and MC twins.
CONCLUSIONS
This study confirms that MC pregnancies have a higher risk of adverse outcomes. However, the outcomes among preterm twins admitted to neonatal intensive care units are similar irrespective of chorionicity
New England Medical Center Posterior Circulation Stroke Registry: I. Methods, Data Base, Distribution of Brain Lesions, Stroke Mechanisms, and Outcomes
Among 407 New England Medical Center Posterior Circulation Registry (NEMC-PCR) patients, 59% had strokes without transient ischemic attacks (TIAs), 24% had TIAs before strokes, and 16% had only posterior circulation TIAs. Embolism was the commonest stroke mechanism accounting for 40% of cases (24% cardiac origin, 14% arterial origin, 2% had potential cardiac and arterial sources). In 32%, large artery occlusive lesions caused hemodynamic brain infarction. Stroke mechanisms in the posterior and anterior circulation are very similar. Infarcts most often included the distal posterior circulation territory (rostral brainstem, superior cerebellum and occipital and temporal lobes), while the proximal (medulla and posterior inferior cerebellum) and middle (pons and anterior inferior cerebellum) territories were equally involved. Infarcts that included the distal territory were twice as common as those that included the proximal or middle territories. Most distal territory infarcts were attributable to embolism. Thirty day mortality was low (3.6%). Embolic stroke mechanism, distal territory location, and basilar artery occlusive disease conveyed the worst prognosis
Expression of Glycogen Phosphorylase Isoforms in Cultured Muscle from Patients with McArdle's Disease Carrying the p.R771PfsX33 PYGM Mutation
Mutations in the PYGM gene encoding skeletal muscle glycogen phosphorylase (GP) cause a metabolic disorder known as McArdle's disease. Previous studies in muscle biopsies and cultured muscle cells from McArdle patients have shown that PYGM mutations abolish GP activity in skeletal muscle, but that the enzyme activity reappears when muscle cells are in culture. The identification of the GP isoenzyme that accounts for this activity remains controversial
Characterization method of dielectric properties of free falling drops in a microwave processing cavity and its application in microwave internal gelation
[EN] Microwave internal gelation (MIG) is a chemical process proposed for the production of nuclear particle fuel. The internal gelation reaction is triggered by a temperature increase of aqueous droplets falling by gravity by means of non-contact microwave heating. Due to the short residence time of a solution droplet in a microwave heating cavity, a detailed knowledge of the interaction between microwaves and chemical solution (shaped in small drops) is required. This paper describes a procedure that enables the measurement of the dielectric properties of aqueous droplets that freely fall through a microwave cavity. These measurements provide the information to determine the optimal values of the parameters (such as frequency and power) that dictate the heating of such a material under microwaves.This work is a part of the PINE (Platform for Innovative Nuclear FuEls) project which targets the development of an advanced production method for Sphere-Pac fuel and is financed by the Swiss Competence Center for Energy and Mobility. The work has been also financed by the European Commission through contract no 295664 regarding the FP7 PELGRIMM Project, as well as contract no 295825 regarding the FP7-ASGARD Project. MC-S would like to thank the ITACA research team (UPV Valencia, Spain) and the EMPA Thun (Switzerland) for their support in the measurements and Carl Beard (PSI, Switzerland) for the help provided in respect with CST simulations. The work of FLP-F was supported by the Conselleria d'Educacio of the Generalitat Valenciana for economic support (BEST/2012/010).Cabanes Sempere, M.; CatalĂĄ Civera, JM.; Penaranda-Foix, FL.; Cozzo, C.; Vaucher, S.; Pouchon, MA. (2013). Characterization method of dielectric properties of free falling drops in a microwave processing cavity and its application in microwave internal gelation. Measurement Science and Technology. 24(9). https://doi.org/10.1088/0957-0233/24/9/095009S24
The effects of neuromuscular electrical stimulation for dysphagia in opercular syndrome: a case study
A 76-year-old man with opercular syndrome characterized by complete bilateral loss of voluntary control of facial, lingual, pharyngeal and masticatory muscles is presented with focus on the severe dysphagia. Three years earlier the patient had experienced two strokes resulting in opercular syndrome with severe dysphagia. Despite initial logopedic dysphagia treatment, swallowing did not improve. A new treatment for dysphagia, consisting of neuromuscular electrical stimulation was applied on the patient. He returned to oral feeding. Clinical and treatment observations are reported
Mobile Manipulation Hackathon: Moving into Real World Applications
The Mobile Manipulation Hackathon was held in late 2018 during the IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) to showcase the latest applications of wheeled robotic manipulators. The challenge had an open format, where teams developed an application using simulation tools and integrated it into a robotic platform. This article presents the competition and analyzes the results, with information gathered during the event and from a survey circulated among the finalist teams. We provide an overview of the mobile manipulation field, identify key areas required for further development to facilitate the implementation of mobile manipulators in real applications, and discuss ideas about how to structure future hackathon-style competitions to enhance their impact on the scientific and industrial communities.Peer ReviewedPostprint (published version
Microwave sensor system for continuous monitoring of adhesive curing processes
A microwave sensor system has been developed for monitoring adhesive curing processes. The system provides continuous, real-time information about the curing progress without interfering with the reaction. An open-coaxial resonator is used as the sensor head, and measurements of its resonance frequency and quality factor are performed during cure to follow the reaction progress. Additionally, the system provides other interesting parameters such as reaction rate or cure time. The adhesive dielectric properties can also be computed off-line, which gives additional information about the process. The results given by the system correlate very well with conventional measurement techniques such as differential scanning calorimetry, combining accuracy and rate with simplicity and an affordable cost. © 2012 IOP Publishing Ltd.The authors thank Rut Benavente Martinez for her assistance in the DSC experiments. The contract of BG-B is financed by the Ministry of Science and Innovation of Spain, through the 'Torres Quevedo' Sub-programme, which is also co-financed by the European Social Fund (ESF). This work has been financed by the Ministry of Science and Innovation of Spain through the project MONIDIEL (TEC2008-04109).GarcĂa Baños, B.; CatalĂĄ Civera, JM.; Penaranda-Foix, FL.; CanĂłs MarĂn, AJ.; Sahuquillo Navarro, O. (2012). Microwave sensor system for continuous monitoring of adhesive curing processes. Measurement Science and Technology. 23(3). https://doi.org/10.1088/0957-0233/23/3/035101S233Jost, M., & Sernek, M. (2008). Shear strength development of the phenolâformaldehyde adhesive bond during cure. Wood Science and Technology, 43(1-2), 153-166. doi:10.1007/s00226-008-0217-2Costa, M. L., Botelho, E. C., Paiva, J. M. F. de, & Rezende, M. C. (2005). Characterization of cure of carbon/epoxy prepreg used in aerospace field. Materials Research, 8(3), 317-322. doi:10.1590/s1516-14392005000300016Chen, J., & Hojjati, M. (2007). Microdielectric analysis and curing kinetics of an epoxy resin system. Polymer Engineering & Science, 47(2), 150-158. doi:10.1002/pen.20687Sernek, M., & Kamke, F. A. (2007). Application of dielectric analysis for monitoring the cure process of phenol formaldehyde adhesive. International Journal of Adhesion and Adhesives, 27(7), 562-567. doi:10.1016/j.ijadhadh.2006.10.004NĂșñez, L., GĂłmez-Barreiro, S., Gracia-FernĂĄndez, C. A., & NĂșñez, M. R. (2004). Use of the dielectric analysis to complement previous thermoanalytical studies on the system diglycidyl ether of bisphenol A/1,2 diamine cyclohexane. Polymer, 45(4), 1167-1175. doi:10.1016/j.polymer.2003.12.024Lefebvre, D. R., Han, J., Lipari, J. M., Long, M. A., McSwain, R. L., & Wells, H. C. (2006). Dielectric analysis for in-situ monitoring of gelatin renaturation and crosslinking. Journal of Applied Polymer Science, 101(5), 2765-2775. doi:10.1002/app.21631Cordovez, M., Li, Y., & Karbhari, V. M. (2004). Assessment of Dielectrometry for Characterization of Processing and Moisture Absorption in FRP Composites. Journal of Reinforced Plastics and Composites, 23(4), 445-456. doi:10.1177/0731684404031980Das, N. K., Voda, S. M., & Pozar, D. M. (1987). Two Methods for the Measurement of Substrate Dielectric Constant. IEEE Transactions on Microwave Theory and Techniques, 35(7), 636-642. doi:10.1109/tmtt.1987.1133722Fioretto, D., Livi, A., Rolla, P. A., Socino, G., & Verdini, L. (1994). The dynamics of poly(n-butyl acrylate) above the glass transition. Journal of Physics: Condensed Matter, 6(28), 5295-5302. doi:10.1088/0953-8984/6/28/007Givot, B. L., Krupka, J., & Belete, D. Y. (s. f.). Split post dielectric resonator technique for dielectric cure monitoring of structural adhesives. 13th International Conference on Microwaves, Radar and Wireless Communications. MIKON - 2000. Conference Proceedings (IEEE Cat. No.00EX428). doi:10.1109/mikon.2000.913931Canos, A. J., Catala-Civera, J. M., Penaranda-Foix, F. L., & Reyes-Davo, E. (2006). A novel technique for deembedding the unloaded resonance frequency from measurements of microwave cavities. IEEE Transactions on Microwave Theory and Techniques, 54(8), 3407-3416. doi:10.1109/tmtt.2006.877833Marks, R. B., & Williams, D. F. (1992). A general waveguide circuit theory. Journal of Research of the National Institute of Standards and Technology, 97(5), 533. doi:10.6028/jres.097.024Harrington, R. F. (1967). Matrix methods for field problems. Proceedings of the IEEE, 55(2), 136-149. doi:10.1109/proc.1967.5433Baker-Jarvis, J., Janezic, M. D., Domich, P. D., & Geyer, R. G. (1994). Analysis of an open-ended coaxial probe with lift-off for nondestructive testing. IEEE Transactions on Instrumentation and Measurement, 43(5), 711-718. doi:10.1109/19.328897Taylor, B. N. (1994). Guidelines for evaluating and expressing the uncertainty of NIST measurement results. doi:10.6028/nist.tn.1297Casalini, R., Corezzi, S., Livi, A., Levita, G., & Rolla, P. A. (1997). Dielectric parameters to monitor the crosslink of epoxy resins. Journal of Applied Polymer Science, 65(1), 17-25. doi:10.1002/(sici)1097-4628(19970705)65:13.0.co;2-tPreu, H., & Mengel, M. (2007). Experimental and theoretical study of a fast curing adhesive. International Journal of Adhesion and Adhesives, 27(4), 330-337. doi:10.1016/j.ijadhadh.2006.06.004Harper, D. P., Wolcott, M. P., & Rials, T. G. (2001). Evaluation of the cure kinetics of the wood/pMDI bondline. International Journal of Adhesion and Adhesives, 21(2), 137-144. doi:10.1016/s0143-7496(00)00045-2Garcia-Banos, B., Canos, A. J., Penaranda-Foix, F. L., & Catala-Civera, J. M. (2011). Noninvasive Monitoring of Polymer Curing Reactions by Dielectrometry. IEEE Sensors Journal, 11(1), 62-70. doi:10.1109/jsen.2010.2050475He, Y. (2001). DSC and DEA studies of underfill curing kinetics. Thermochimica Acta, 367-368, 101-106. doi:10.1016/s0040-6031(00)00654-7NĂșñez-Regueira, L., Gracia-FernĂĄndez, C. A., & GĂłmez-Barreiro, S. (2005). Use of rheology, dielectric analysis and differential scanning calorimetry for gel time determination of a thermoset. Polymer, 46(16), 5979-5985. doi:10.1016/j.polymer.2005.05.06
- âŠ