11 research outputs found

    Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

    No full text
    The use of medium cut-off (MCO) polyarylethersulfone and polyvinylpyrrolidone blend membrane is an emerging mode in hemodialysis. Recent studies have shown that MCO membranes exhibit a middle high molecular weight uremic toxin clearance superior to standard high flux hemodialysis. We conducted a systematic literature review and meta-analysis of randomized controlled trials to investigate whether MCO membranes efficiently increase the reduction ratio of middle molecules, and to explore the potential clinical applications of MCO membranes. We selected articles that compared beta 2-microglobulin (β2M), kappa free light chain (κFLC), lambda free light chain (λFLC), interleukin-6 (IL-6), and albumin levels among patients undergoing hemodialysis. Five randomized studies with 328 patients were included. The meta-analysis demonstrated a significantly higher reduction ratio of serum β2M (p < 0.0001), κFLC (p < 0.0001), and λFLC (p = 0.02) in the MCO group. No significant difference was found in serum IL-6 levels after hemodialysis. Albumin loss was observed in the MCO group (p = 0.04). In conclusion, this meta-analysis study demonstrated the MCO membranes’ superior ability to clear β2M, κFLC, and λFLC. Serum albumin loss is an issue and should be monitored. Further studies are expected to identify whether MCO membranes could significantly improve clinical outcomes and overall survival

    Comparison of the removal of uraemic toxins with medium cut-off and high-flux dialysers: a randomized clinical trial

    No full text
    International audienceBACKGROUND:Accumulation of middle-weight uraemic toxins in haemodialysis (HD) patients results in increased morbidity and mortality. Whether medium cut-off HD (MCO-HD) improves removal of middle-weight uraemic toxins remains to be demonstrated.METHODS: This cross-over prospective study included 40 patients randomly assigned to receive either 3 months of MCO-HD followed by 3 months of high-flux HD (HF-HD), or vice versa. The primary endpoint was myoglobin reduction ratio (RR) after 3 months of MCO-HD. Secondary endpoints were the effect of MCO-HD on other middle-weight toxins and protein-bound toxins, and on parameters of nutrition, inflammation, anaemia and oxidative stress.RESULTS: Compared with HF-HD, MCO-HD provided higher mean RR of myoglobin (36 ± 8 versus 57 ± 13%, P < 0.0001), beta2-microglobulin (68 ± 6 versus 73 ± 15%, P = 0.04), prolactin (32 ± 13 versus 59 ± 11%, P < 0.0001), fibroblast growth factor 23 (20 ± 21 versus 41 ± 22%, P = 0.0002), homocysteine (43 ± 7 versus 46 ± 9%, P = 0.03) and higher median RR of kappa [54 (48-58) versus 70 (63-74)%, P < 0.0001] and lambda free light chain (FLC) [15 (9-22) versus 44 (38-49)%, P < 0.0001]. Mean ± SD pre-dialysis levels of beta2-microglobulin (28.4 ± 5.6 versus 26.9 ± 5.1 mg/L, P = 0.01) and oxidized low-density lipoprote (6.9 ± 4.4 versus 5.5 ± 2.5 pg/mL, P = 0.04), and median (interquartile range) kappa FLC [145 (104-203) versus 129 (109-190) mg/L, P < 0.03] and lambda FLC [106 (77-132) versus 89 (62-125) mg/L, P = 0.002] were significantly lower. Mean albumin levels decreased significantly (38.2 ± 4.1 versus 36.9 ± 4.3 g/L, P = 0.004), without an effect on nutritional status as suggested by unchanged normalized protein catabolic rate and transthyretin level.CONCLUSIONS: Compared with HF-HD, MCO-HD provides higher myoglobin and other middle molecules RR and is associated with moderate hypoalbuminemia. The potential benefits of this strategy on long-term clinical outcomes deserve further evaluation

    Overexposure to Bisphenol A and Its Chlorinated Derivatives of Patients with End-Stage Renal Disease during Online Hemodiafiltration

    No full text
    International audienceThe health safety conditions governing the practice of online hemodiafiltration (OL-HDF) do not yet incorporate the risks related to the presence of endocrine disruptors such as bisphenol A (BPA). The aim of this study was to assess, for the first time, the exposure to BPA but also to its chlorinated derivatives (ClxBPA) (100 times more estrogenic than BPA) during OL-HDF. We demonstrated that BPA is transmitted by the different medical devices used in OL-HDF: ultrafilters, dialysis concentrate cartridges (and not only dialyzers, as previously described). Moreover, BPA has been found in dialysis water as well as in ultrapure dialysate and replacement fluid due to contamination of water coming from municipal network. Indeed, due to contaminations provided by both ultrafilters and water, high levels of BPA were determined in the infused replacement fluid (1033 ng.L−1) from the beginning of the session. Thus, our results demonstrate that dialysis water must be considered as an important exposure source to endocrine disruptors, especially since other micropollutants such as ClxBPA have also been detected in dialysis fluids. While assessment of the impact of this exposure remains to be done, these new findings should be taken into account to assess exposure risks in end-stage renal disease patient
    corecore