794 research outputs found
Geoneutrinos in Borexino
This paper describes the Borexino detector and the high-radiopurity studies
and tests that are integral part of the Borexino technology and development.
The application of Borexino to the detection and studies of geoneutrinos is
discussed.Comment: Conference: Neutrino Geophysics Honolulu, Hawaii December 14-16, 200
Double-beta decay of Te to the first 0 excited state of Xe with CUORICINO
The CUORICINO experiment was an array of 62 TeO single-crystal
bolometers with a total Te mass of kg. The experiment finished
in 2008 after more than 3 years of active operating time. Searches for both
and double-beta decay to the first excited state in
Xe were performed by studying different coincidence scenarios. The
analysis was based on data representing a total exposure of
N(Te)t=y. No evidence for a signal was
found. The resulting lower limits on the half lives are y (90% C.L.), and
y (90%
C.L.).Comment: 6 pages, 4 figure
GNO Solar Neutrino Observations: Results for GNOI
We report the first GNO solar neutrino results for the measuring period GNOI,
solar exposure time May 20, 1998 till January 12, 2000. In the present
analysis, counting results for solar runs SR1 - SR19 were used till April 4,
2000. With counting completed for all but the last 3 runs (SR17 - SR19), the
GNO I result is [65.8 +10.2 -9.6 (stat.) +3.4 -3.6 (syst.)]SNU (1sigma) or
[65.8 + 10.7 -10.2 (incl. syst.)]SNU (1sigma) with errors combined. This may be
compared to the result for Gallex(I-IV), which is [77.5 +7.6 -7.8 (incl.
syst.)] SNU (1sigma). A combined result from both GNOI and Gallex(I-IV)
together is [74.1 + 6.7 -6.8 (incl. syst.)] SNU (1sigma).Comment: submitted to Physics Letters B, June 2000. PACS: 26.65. +t ; 14.60
Pq. Corresponding author: [email protected] ; [email protected]
A New Limit on the Neutrinoless DBD of 130Te
We report the present results of CUORICINO a cryogenic experiment on
neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62
crystals of TeO2 with a total active mass of 40.7 kg. The array is framed
inside of a dilution refrigerator, heavily shielded against environmental
radioactivity and high-energy neutrons, and operated at a temperature of ~8 mK
in the Gran Sasso Underground Laboratory. Temperature pulses induced by
particle interacting in the crystals are recorded and measured by means of
Neutron Transmutation Doped thermistors. The gain of each bolometer is
stabilized with voltage pulses developed by a high stability pulse generator
across heater resistors put in thermal contact with the absorber.
The calibration is performed by means of two thoriated wires routinely
inserted in the set-up. No evidence for a peak indicating neutrinoless DBD of
130Te is detected and a 90% C.L. lower limit of 1.8E24 years is set for the
lifetime of this process. Taking largely into account the uncertainties in the
theoretical values of nuclear matrix elements, this implies an upper boud on
the effective mass of the electron neutrino ranging from 0.2 to 1.1 eV. This
sensitivity is similar to those of the 76Ge experiments.Comment: 4 pages, 2 figure
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.Comment: 22 pages, 15 figures, submitted to EPJ
CUORE: A Cryogenic Underground Observatory for Rare Events
CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being
a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical
towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers
of 4 crystals. The design of the detector is optimized for ultralow-background
searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold
dark matter, solar axions, and rare nuclear decays. A preliminary experiment
involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE
tower is being constructed as a smaller scale experiment called CUORICINO. The
expected performance and sensitivity, based on Monte Carlo simulations and
extrapolations of present results, are reported.Comment: 39 pages, 12 figures, submitted to NI
Search for 14.4 keV solar axions from M1 transition of Fe-57 with CUORE crystals
We report the results of a search for axions from the 14.4 keV M1 transition
from Fe-57 in the core of the sun using the axio-electric effect in TeO2
bolometers. The detectors are 5x5x5 cm3 crystals operated at about 10 mK in a
facility used to test bolometers for the CUORE experiment at the Laboratori
Nazionali del Gran Sasso in Italy. An analysis of 43.65 kg d of data was made
using a newly developed low energy trigger which was optimized to reduce the
detectors energy threshold. An upper limit of 0.63 c kg-1 d-1 was established
at 95% C.L.. From this value, a lower bound at 95% C.L. was placed on the
Peccei-Quinn energy scale of fa >= 0.76 10**6 GeV for a value of S=0.55 for the
flavor-singlet axial vector matrix element. Bounds are given for the interval
0.15 < S < 0.55.Comment: 14 pages, 6 figures, submitted to JCA
Search for Neutrinoless Double-Beta Decay of Te with CUORE-0
We report the results of a search for neutrinoless double-beta decay in a
9.8~kgyr exposure of Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are FWHM and ~counts/(keVkgyr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of Te and place a
Bayesian lower bound on the decay half-life, ~ at 90%~C.L. Combining CUORE-0 data with the 19.75~kgyr
exposure of Te from the Cuoricino experiment we obtain at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
-- .Comment: 6 pages, 5 figures, updated version as published in PR
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.Comment: 9 pages, 10 figure
- …
