535 research outputs found

    Revision of a Failed Primary Total Hip Arthroplasty following Excessive Reaming with a Medial Cup Protrusion.

    Get PDF
    Background and Objectives: Atraumatic intrapelvic protrusion of the acetabular component following excessive reaming of the acetabulum with a far medial positioning of the cup is a rare, but serious complication of a total hip arthroplasty (THA). This study analyzes the factors contributing to this uncommon complication and presents the outcome after the revision surgery using the Ganz reinforcement ring combined with a bone graft and plating of the posterior column and/or screws for the anterior column. Materials and Methods: A retrospective case series study with seven patients (four males, mean age 76 ± 10 years (60-86)) that underwent a revision THA within 24 ± 17 days (5-60) after an atraumatic periprosthetic acetabular fracture with a medial cup protrusion was performed. All fractures were reconstructed with a Ganz reinforcement ring and bone graft with a mean follow-up of 1.7 ± 1.7 years (0.5-5). Radiographs were evaluated for the following: (i) cup positioning immediately after the primary THA and the revision surgery, (ii) cup migration in the follow-up, and (iii) fracture healing. Results: The position of the acetabular component as assessed on the postoperative radiographs after the index surgery and before the complete medial cup protrusion showed a cup placement beyond the ilioischial line indicative of a fracture of the medial wall. The revision surgery with the reconstruction of the medial wall with a Ganz reinforcement ring combined with a bone graft restored in the presented cases the center of rotation in the horizontal direction with a statistical significance (p < 0.05). During the follow-up, there was no aseptic loosening with the relevant cup migration or significant change in the position of the acetabular cup at the final follow-up (p > 0.05) after the revision. All seven fractures and bone grafts realized a bone union until the latest follow-up. Conclusions: Following excessive reaming, the acetabular component was placed too far medially and resulted in an intrapelvic cup protrusion. An unstable cup following a fracture of the medial wall was evident on the immediate postoperative radiographs. In the case of the medial wall perforation with an intrapelvic cup protrusion after the primary THA, the reconstruction with a Ganz reinforcement ring was a successful treatment option resulting in the fracture healing and a stable cup positioning. Surgeons should be aware of that rare and probably underreported complication and restore the anatomic center of rotation by treating the defect intraoperatively

    On the de Haas-van Alphen effect in inhomogeneous alloys

    Full text link
    We show that Landau level broadening in alloys occurs naturally as a consequence of random variations in the local quasiparticle density, without the need to consider a relaxation time. This approach predicts Lorentzian-broadened Landau levels similar to those derived by Dingle using the relaxation-time approximation. However, rather than being determined by a finite relaxation time τ\tau, the Landau-level widths instead depend directly on the rate at which the de Haas-van Alphen frequency changes with alloy composition. The results are in good agreement with recent data from three very different alloy systems.Comment: 5 pages, no figure

    Influence of normal and radial contributions of local current density on local electrochemical impedance spectroscopy.

    Get PDF
    A new tri-electrode probe is presented and applied to local electrochemical impedance spectroscopy (LEIS) measurements. As opposed to two-probe systems, the three-probe one allows measurement not only of normal, but also of radial contributions of local current densities to the local impedance values. The results concerning the cases of the blocking electrode and the electrode with faradaic reaction are discussed from the theoretical point of view for a disk electrode. Numerical simulations and experimental results are compared for the case of the ferri/ferrocyanide electrode reaction at the Pt working electrode disk. At the centre of the disk, the impedance taking into account both normal and radial contributions was in good agreement with the local impedance measured in terms of only the normal contribution. At the periphery of the electrode, the impedance taking into account both normal and radial contributions differed significantly from the local impedance measured in terms of only the normal contribution. The radial impedance results at the periphery of the electrode are in good agreement with the usual explanation that the associated larger current density is attributed to the geometry of the electrode, which exhibits a greater accessibility at the electrode edge

    A falls prevention programme to improve quality of life, physical function and falls efficacy in older people receiving home help services: study protocol for a randomised controlled trial

    Get PDF
    BACKGROUND: Falls and fall-related injuries in older adults are associated with great burdens, both for the individuals, the health care system and the society. Previous research has shown evidence for the efficiency of exercise as falls prevention. An understudied group are older adults receiving home help services, and the effect of a falls prevention programme on health-related quality of life is unclear. The primary aim of this randomised controlled trial is to examine the effect of a falls prevention programme on quality of life, physical function and falls efficacy in older adults receiving home help services. A secondary aim is to explore the mediating factors between falls prevention and health-related quality of life. METHODS: The study is a single-blinded randomised controlled trial. Participants are older adults, aged 67 or older, receiving home help services, who are able to walk with or without walking aids, who have experienced at least one fall during the last 12 months and who have a Mini Mental State Examination of 23 or above. The intervention group receives a programme, based on the Otago Exercise Programme, lasting 12 weeks including home visits and motivational telephone calls. The control group receives usual care. The primary outcome is health-related quality of life (SF-36). Secondary outcomes are leg strength, balance, walking speed, walking habits, activities of daily living, nutritional status and falls efficacy. All measurements are performed at baseline, following intervention at 3 months and at 6 months' follow-up. Sample size, based on the primary outcome, is set to 150 participants randomised into the two arms, including an estimated 15-20% drop out. Participants are recruited from six municipalities in Norway. DISCUSSION: This trial will generate new knowledge on the effects of an exercise falls prevention programme among older fallers receiving home help services. This knowledge will be useful for clinicians, for health managers in the primary health care service and for policy makers

    Transiting exoplanets from the CoRoT space mission VIII. CoRoT-7b: the first Super-Earth with measured radius

    Get PDF
    We report the discovery of very shallow (DF/F = 3.4 10-4), periodic dips in the light curve of an active V = 11.7 G9V star observed by the CoRoT satellite, which we interpret as due to the presence of a transiting companion. We describe the 3-colour CoRoT data and complementary ground-based observations that support the planetary nature of the companion. Methods. We use CoRoT color information, good angular resolution ground-based photometric observations in- and out- of transit, adaptive optics imaging, near-infrared spectroscopy and preliminary results from Radial Velocity measurements, to test the diluted eclipsing binary scenarios. The parameters of the host star are derived from optical spectra, which were then combined with the CoRoT light curve to derive parameters of the companion. We examine carefully all conceivable cases of false positives, and all tests performed support the planetary hypothesis. Blends with separation larger than 0.40 arcsec or triple systems are almost excluded with a 8 10-4 risk left. We conclude that, as far as we have been exhaustive, we have discovered a planetary companion, named CoRoT-7b, for which we derive a period of 0.853 59 +/- 3 10-5 day and a radius of Rp = 1.68 +/- 0.09 REarth. Analysis of preliminary radial velocity data yields an upper limit of 21 MEarth for the companion mass, supporting the finding. CoRoT-7b is very likely the first Super-Earth with a measured radius.Comment: Accepted in Astronomy and Astrophysics; typos and language corrections; version sent to the printer w few upgrade

    UV and EUV Instruments

    Full text link
    We describe telescopes and instruments that were developed and used for astronomical research in the ultraviolet (UV) and extreme ultraviolet (EUV) regions of the electromagnetic spectrum. The wavelength ranges covered by these bands are not uniquely defined. We use the following convention here: The EUV and UV span the regions ~100-912 and 912-3000 Angstroem respectively. The limitation between both ranges is a natural choice, because the hydrogen Lyman absorption edge is located at 912 Angstroem. At smaller wavelengths, astronomical sources are strongly absorbed by the interstellar medium. It also marks a technical limit, because telescopes and instruments are of different design. In the EUV range, the technology is strongly related to that utilized in X-ray astronomy, while in the UV range the instruments in many cases have their roots in optical astronomy. We will, therefore, describe the UV and EUV instruments in appropriate conciseness and refer to the respective chapters of this volume for more technical details.Comment: To appear in: Landolt-Boernstein, New Series VI/4A, Astronomy, Astrophysics, and Cosmology; Instruments and Methods, ed. J.E. Truemper, Springer-Verlag, Berlin, 201

    An inclusive search for free quarks at PEP

    Get PDF
    Abstract We report the results of a search for fractionally charged particles in e + e − reactions at a center of mass energy of 29 GeV. We find no evidence for such particles and present upper limitts on R q = σ q q X/σ μμ for change 1 3 e and 2 3 e which range from 1 to 8 × 10 −2 for mass up to 12 GeV/ c 2

    Hadron Energy Reconstruction for the ATLAS Calorimetry in the Framework of the Non-parametrical Method

    Get PDF
    This paper discusses hadron energy reconstruction for the ATLAS barrel prototype combined calorimeter (consisting of a lead-liquid argon electromagnetic part and an iron-scintillator hadronic part) in the framework of the non-parametrical method. The non-parametrical method utilizes only the known e/he/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. Thus, this technique lends itself to an easy use in a first level trigger. The reconstructed mean values of the hadron energies are within ±1\pm 1% of the true values and the fractional energy resolution is [(58±3)/E+(2.5±0.3)[(58\pm3)% /\sqrt{E}+(2.5\pm0.3)%]\oplus (1.7\pm0.2)/E. The value of the e/he/h ratio obtained for the electromagnetic compartment of the combined calorimeter is 1.74±0.041.74\pm0.04 and agrees with the prediction that e/h>1.7e/h > 1.7 for this electromagnetic calorimeter. Results of a study of the longitudinal hadronic shower development are also presented. The data have been taken in the H8 beam line of the CERN SPS using pions of energies from 10 to 300 GeV.Comment: 33 pages, 13 figures, Will be published in NIM

    Search for fractionally charged particles in cosmic rays at large zenith angles

    Get PDF
    We have performed a single-particle search for fractional charge in cosmic rays having residual ranges at sea level >250 g/cm/sup 2/ concrete and zenith angles between 45/sup 0/ and 90/sup 0/. The detector is a hodoscope of 24 layers of plastic scintillator, eight layers of multiwire proportional chambers, and two layers of lucite Cherenkov counters. The acceptance of the instrument is 4.0 x 10/sup 3/ cm/sup 2/sr. An analysis of 3.5 x 10/sup 6/ triggers during a running time of 8 x 10/sup 5/ sec yields no particles with charge Q = (1/3) or Q = (2/3) and velocities greater than roughly-equal0.1c. We deduce an upper limit on the flux of fractionally charged particles of 8.5 x 10/sup -10/ (cm/sup 2/sr sec)/sup -1/ for relativistic Q = (1/3) and 7.6 x 10/sup -10/ (cm/sup 2/sr sec)/sup -1/ for Q = (2/3)
    corecore