95 research outputs found

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3–4 microns RMS in the barrel and 3–14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Commissioning and performance of the CMS pixel tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published verion of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Performance of the CMS drift-tube chamber local trigger with cosmic rays

    Get PDF
    The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams

    Performance of the CMS Level-1 trigger during commissioning with cosmic ray muons and LHC beams

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPThe CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Performance of the CMS hadron calorimeter with cosmic ray muons and LHC beam data

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Performance of the CMS Level-1 trigger during commissioning with cosmic ray muons and LHC beams

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPThe CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Performance study of the CMS barrel resistive plate chambers with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPIn October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    DISCORDANCE BETWEEN BODY MASS INDEX AND ANTHROPOMETRIC MEASUREMENTS AMONG HIV-1-INFECTED PATIENTS ON ANTIRETROVIRAL THERAPY AND WITH LIPOATROPHY/LIPOHYPERTROPHY SYNDROME

    Get PDF
    Objetivos: A terapia antirretroviral altamente ativa (HAART) tem melhorado e aumentado a vida de milhares de pessoas que vivem com a infecção pelo HIV/AIDS em todo o mundo. No entanto, este tratamento pode levar ao desenvolvimento da síndrome da lipodistrofia (LDS). Este estudo foi desenvolvido para avaliar a prevalência de auto-relato de LDS, perfil nutricional e medidas antropomÊtricas de pacientes com HIV/AIDS. MÊtodos: Estudo observacional de 227 pacientes adultos, divididos em: Grupo 1: 92 pacientes em HAART e com LDS; Grupo 2: 70 pacientes em tratamento com HAART e sem LDS e Grupo 3: 65 pacientes que não tomam HAART. O estado nutricional foi avaliado pelo índice de massa corporal (IMC) e o percentual de gordura corporal (%GC) por meio de medidas antropomÊtricas. Resultados: A prevalência de auto-relato de LDS foi de 44% entre as mulheres e 39% entre os homens. DC do tríceps (PCT) apresentou-se mais elevada no grupo HAART e LDS (homens p < 0,001; mulheres p < 0,007) em comparação com aqueles sem HAART, respectivamente. IMC revelou excesso de peso para a maioria dos indivíduos. Conclusþes: As medidas antropomÊtricas foram úteis para confirmar a prevalência de auto-relato da síndrome da lipodistrofia. A avaliação das dobras dos braços e pernas revelou-se um bom mÊtodo para avaliação antropomÊtrica de lipoatrofia de membro, independentemente do sexo. Estes resultados permitiram o estabelecimento de estratÊgias para o diagnóstico precoce da LDS na pråtica clínica, em pessoas vivendo com HIV / AIDS.Introduction: Highly Active Antiretroviral Therapy (HAART) has improved and extended the lives of thousands of people living with HIV/AIDS around the world. However, this treatment can lead to the development of adverse reactions such as lipoatrophy/lipohypertrophy syndrome (LLS) and its associated risks. Objective: This study was designed to assess the prevalence of self-reported lipodystrophy and nutritional status by anthropometric measurements in patients with HIV/AIDS. Methods: An observational study of 227 adult patients in the Secondary Immunodeficiencies Outpatient Department of Dermatology, Hospital das Clínicas, Faculty of Medicine, University of São Paulo (3002 ADEE-HCFMUSP). The sample was divided into three groups; Group 1 = 92 patients on HAART and with self-reported lipodystrophy, Group 2 = 70 patients on HAART without self-reported lipodystrophy and Group 3 = 65 patients not taking HAART. The nutritional status of individuals in the study sample was determined by body mass index (BMI) and percentage of body fat (% BF). The cardiovascular risk and diseases associated with abdominal obesity were determined by waist/hip ratio (WHR) and waist circumference (WC). Results: The prevalence of self-reported lipoatrophy/lipohypertrophy syndrome was 33% among women and 59% among men. Anthropometry showed depletion of fat mass in the evaluation of the triceps (TSF) in the treatment groups with HAART and was statistically independent of gender; for men p = 0.001, and for women p = 0.007. Similar results were found in the measurement of skin folds of the upper and lower body (p = 0.001 and p = 0.003 respectively). In assessing the nutritional status of groups by BMI and % BF, excess weight and body fat were more prevalent among women compared to men (p = 0.726). The WHR and WC revealed risks for cardiovascular and other diseases associated with abdominal obesity for women on HAART and with self-reported LLS (p = 0.005) and (p = 0.011). Conclusions: Anthropometric measurements were useful in the confirmation of the prevalence of LLS. BMI alone does not appear to be a good parameter for assessing the nutritional status of HIV-infected patients on HAART and with LLS. Other anthropometric measurements are needed to evaluate patients with the lipoatrophy/lipohypertrophy syndrome

    IL-12 and neutralization of endogenous IL-10 revert the in vitro antigen-specific cellular immunosuppression of paracoccidioidomycosis patients

    No full text
    Treatment of patients with paracoccidioidomycosis is still a challenge. Patients present defective lymphoproliferation and IFN-γ responses to the main Paracoccidioides brasiliensis antigen (gp43), which correlates with disease severity. Here, we demonstrated that the patients show also a defective synthesis of interleukin (IL)-12. Therefore, we attempted to revert this immune disfunction by adding IL-12 and neutralizing anti-IL-10 antibody to gp-43-stimulated peripheral blood mononuclear cell cultures. Both treatments increased IFN-γ secretion to levels observed with healthy sensitized individuals, but affected proliferation only modestly. When combined, the treatments further increased IFN-γ synthesis and cell proliferation. The addition of suboptimal concentrations of IL-2 also further increased the IL-12-mediated secretion of IFN-γ. Interestingly, the immune modulation was mostly antigen-specific, since the responses to Candida albicans' antigen were not affected. These results suggest that appropriate immune intervention with cytokines and/or anti-cytokines may help in the treatment of PCM. Š 2002 Elsevier Science Ltd. All rights reserved
    • …
    corecore