113 research outputs found

    Precision on leptonic mixing parameters at future neutrino oscillation experiments

    Get PDF
    We perform a comparison of the different future neutrino oscillation experiments based on the achievable precision in the determination of the fundamental parameters theta_{13} and the CP phase, delta, assuming that theta_{13} is in the range indicated by the recent Daya Bay measurement. We study the non-trivial dependence of the error on delta on its true value. When matter effects are small, the largest error is found at the points where CP violation is maximal, and the smallest at the CP conserving points. The situation is different when matter effects are sizable. As a result of this effect, the comparison of the physics reach of different experiments on the basis of the CP discovery potential, as usually done, can be misleading. We have compared various proposed super-beam, beta-beam and neutrino factory setups on the basis of the relative precision of theta_{13} and the error on delta. Neutrino factories, both high-energy or low-energy, outperform alternative beam technologies. An ultimate precision on theta_{13} below 3% and an error on delta of < 7^{\circ} at 1 sigma (1 d.o.f.) can be obtained at a neutrino factory.Comment: Minor changes, matches version accepted in JHEP. 30 pages, 9 figure

    MICE: The muon ionization cooling experiment. Step I: First measurement of emittance with particle physics detectors

    Get PDF
    Copyright @ 2011 APSThe Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.This work was supported by NSF grant PHY-0842798

    Use of neuroleptics in a general hospital

    Get PDF
    BACKGROUND: This study investigates the clinical use of neuroleptics within a general hospital in acutely ill medical or surgical patients and its relation with dementia three months after admission compared with control subjects. METHODS: Cases were defined as every adult patient to whom a neuroleptic medication was prescribed during their hospitalization in our Hospital from February 1(st), to June 30(th), 1998. A control matched by age and sex was randomly selected among patients who had been admitted in the same period, in the same department, and had not received neuroleptics drugs (205 cases and 200 controls). Demographic, clinical and complementary data were compared between cases and controls. Crude odds ratios estimating the risk of dementia in non previously demented subjects compared with the risk in non-demented control subjects were calculated. RESULTS: 205 of 2665 patients (7.7%) received a neuroleptic drug. The mean age was 80.0 ± 13.6 years and 52% were females. They were older and stayed longer than the rest of the population. Only 11% received a psychological evaluation before the prescription. Fifty two percent were agitated while 40% had no reason justifying the use of neuroleptic drug. Three months after neuroleptic use 27% of the surviving cases and 2.6% of the surviving controls who were judged non-demented at admission were identified as demented. CONCLUSIONS: The most common reason for neuroleptic treatment was to manage agitation symptomatically in hospitalised patients. Organic mental syndromes were rarely investigated, and mental status exams were generally absent. Most of neuroleptic recipients had either recognised or unrecognised dementia

    Non-standard interactions versus non-unitary lepton flavor mixing at a neutrino factory

    Full text link
    The impact of heavy mediators on neutrino oscillations is typically described by non-standard four-fermion interactions (NSIs) or non-unitarity (NU). We focus on leptonic dimension-six effective operators which do not produce charged lepton flavor violation. These operators lead to particular correlations among neutrino production, propagation, and detection non-standard effects. We point out that these NSIs and NU phenomenologically lead, in fact, to very similar effects for a neutrino factory, for completely different fundamental reasons. We discuss how the parameters and probabilities are related in this case, and compare the sensitivities. We demonstrate that the NSIs and NU can, in principle, be distinguished for large enough effects at the example of non-standard effects in the μ\mu-τ\tau-sector, which basically corresponds to differentiating between scalars and fermions as heavy mediators as leading order effect. However, we find that a near detector at superbeams could provide very synergistic information, since the correlation between source and matter NSIs is broken for hadronic neutrino production, while NU is a fundamental effect present at any experiment.Comment: 32 pages, 5 figures. Final version published in JHEP. v3: Typo in Eq. (27) correcte

    Efficacy and tolerability of gemtuzumab ozogamicin (anti-CD33 monoclonal antibody, CMA-676, Mylotarg(®)) in children with relapsed/refractory myeloid leukemia

    Get PDF
    BACKGROUND: Gemtuzumab ozogamicin (GO) is a cytotoxic anti-CD33 monoclonal antibody that has given promising preliminary results in adult myeloid CD33+ AML. We conducted a retrospective multicenter study of 12 children treated with GO on a compassionate basis (median age 5.5 y). Three patients (2 MDS/AML, 1 JMML) were refractory to first-line treatment, 8 patients with de novo AML were in refractory first relapse, and one patient with de novo AML was in 2(nd )relapse after stem cell transplantation (SCT). CD33 expression exceeded 20% in all cases. METHODS: GO was administered alone, at a unit dose of 3–9 mg/m(2), once (3 patients), twice (3 patients), three (5 patients) or five times (1 patient). Mean follow-up was 128 days (8–585 d). RESULTS: There were three complete responses (25%) leading to further curative treatment (SCT). Treatment failed in the other nine patients, and only one patient was alive at the end of follow-up. NCI-CTC grade III/IV adverse events comprised hematological toxicity (n = 12), hypertransaminasemia (n = 2), allergy and hyperbilirubinemia (1 case each). There was only one major adverse event (grade IV allergy). No case of sinusoidal obstruction syndrome occurred. CONCLUSION: These results warrant a prospective trial of GO in a larger population of children with AML

    Requirements for a New Detector at the South Pole Receiving an Accelerator Neutrino Beam

    Full text link
    There are recent considerations to increase the photomultiplier density in the IceCube detector array beyond that of DeepCore, which will lead to a lower detection threshold and a huge fiducial mass for the neutrino detection. This initiative is known as "Phased IceCube Next Generation Upgrade" (PINGU). We discuss the possibility to send a neutrino beam from one of the major accelerator laboratories in the Northern hemisphere to such a detector. Such an experiment would be unique in the sense that it would be the only neutrino beam where the baseline crosses the Earth's core. We study the detector requirements for a beta beam, a neutrino factory beam, and a superbeam, where we consider both the cases of small theta_13 and large theta_13, as suggested by the recent T2K and Double Chooz results. We illustrate that a flavor-clean beta beam best suits the requirements of such a detector, in particular, that PINGU may replace a magic baseline detector for small values of theta_13 -- even in the absence of any energy resolution capability. For large theta_13, however, a single-baseline beta beam experiment cannot compete if it is constrained by the CERN-SPS. For a neutrino factory, because of the missing charge identification possibility in the detector, a very good energy resolution is required. If this can be achieved, especially a low energy neutrino factory, which does not suffer from the tau contamination, may be an interesting option for large theta_13. For the superbeam, where we use the LBNE beam as a reference, electron neutrino flavor identification and statistics are two of the main limitations. Finally, we demonstrate that, at least in principle, neutrino factory and superbeam can measure the density of the Earth's core to the sub-percent level for sin^2 2theta_13 larger than 0.01.Comment: 34 pages, 15 figures. Minor changes and accepted in JHE

    Non-Standard Interactions at a Neutrino Factory: Correlations and CP violation

    Full text link
    We explore the potential of several Neutrino Factory (NF) setups to constrain, discover and measure new physics effects due to Non-Standard Interactions (NSI) in propagation through Earth matter. We first study the impact of NSI in the measurement of θ13\theta_{13}: we find that these could be large due to strong correlations of θ13\theta_{13} with NSI parameters in the golden channel, and the inclusion of a detector at the magic baseline is crucial in order to reduce them as much as possible. We present, then, the sensitivity of the considered NF setups to the NSI parameters, paying special attention to correlations arising between them and the standard oscillation parameters, when all NSI parameters are introduced at once. Off-diagonal NSI parameters could be tested down to the level of 10310^{-3}, whereas the diagonal combinations (ϵeeϵττ)(\epsilon_{ee} - \epsilon_{\tau\tau}) and (ϵμμϵττ)(\epsilon_{\mu\mu}-\epsilon_{\tau\tau}) can be tested down to 10110^{-1} and 10210^{-2}, respectively. The possibilities of observing CP violation in this context are also explored, by presenting a first scan of the CP discovery potential of the NF setups to the phases ϕeμ,ϕeτ\phi_{e\mu}, \phi_{e\tau} and δ\delta. We study separately the case where CP violation comes only from non-standard sources, and the case where it is entangled with the standard source, δ\delta. In case δ\delta turns out to be CP conserving, the interesting possibility of observing CP violation for reasonably small values of the NSI parameters emerges.Comment: Final note added. 38 pages, 11 figure

    Neutrinos from Stored Muons nuSTORM: Expression of Interest

    Get PDF
    The nuSTORM facility has been designed to deliver beams of electron and muon neutrinos from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum spread of 10%. The facility is unique in that it will: serve the future long- and short-baseline neutrino-oscillation programmes by providing definitive measurements of electron-neutrino- and muon-neutrino-nucleus cross sections with percent-level precision; allow searches for sterile neutrinos of exquisite sensitivity to be carried out; and constitute the essential first step in the incremental development of muon accelerators as a powerful new technique for particle physics. Of the world's proton-accelerator laboratories, only CERN and FNAL have the infrastructure required to mount nuSTORM. Since no siting decision has yet been taken, the purpose of this Expression of Interest (EoI) is to request the resources required to: investigate in detail how nuSTORM could be implemented at CERN; and develop options for decisive European contributions to the nuSTORM facility and experimental programme wherever the facility is sited. The EoI defines a two-year programme culminating in the delivery of a Technical Design Report

    Light sterile neutrino sensitivity at the nuSTORM facility

    Get PDF
    A facility that can deliver beams of electron and muon neutrinos from the decay of a stored muon beam has the potential to unambiguously resolve the issue of the evidence for light sterile neutrinos that arises in short-baseline neutrino oscillation experiments and from estimates of the effective number of neutrino flavors from fits to cosmological data. In this paper, we show that the nuSTORM facility, with stored muons of 3.8 GeV/c ± 10%, will be able to carry out a conclusive muon neutrino appearance search for sterile neutrinos and test the LSND and MiniBooNE experimental signals with 10σ sensitivity, even assuming conservative estimates for the systematic uncertainties. This experiment would add greatly to our knowledge of the contribution of light sterile neutrinos to the number of effective neutrino flavors from the abundance of primordial helium production and from constraints on neutrino energy density from the cosmic microwave background. The appearance search is complemented by a simultaneous muon neutrino disappearance analysis that will facilitate tests of various sterile neutrino models

    Electron-muon ranger: performance in the MICE muon beam

    Get PDF
    The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100–280 MeV/c
    corecore