610 research outputs found

    Green textile dyeing process by using natural dyes: a review

    Get PDF
    In the textile industry, up to 200,000 tons of dyes are lost to effluents every year during the dyeing and finishing operations, due to the inefficiency of the dyeing process. Today, the textile industry used average six hundred dyes and chemical for the in production of textile dyeing industry (Christy, 2014). Due to the toxicity of dyes and chemicals used in textile dyeing processes has led to both human health and environment directly or indirectly. Therefore, “Go-green” or going green is one alternative way to maintain the sustainability and productivity of textile dyeing industry hence maintaining natural ecological balance in the environment and preserving its natural system and resources. The textile dyeing industry makes a big contribution to the economic growth and has become a massive industry throughout the years. This is because higher demand in the production of synthetic dyes since they are affordable, good colour fastness, has various of colours available and are easy to manufacture. However, the environmental impact arising from these industries aroused attention in today’s society. In terms of pollution, the textile dyeing industries has been condemned as one of the world’s most offensive industry among other sectors in the world. In fact, World Bank stated that textile processing polluted 20% of water pollution globally

    The 2023 wearable photoplethysmography roadmap

    Get PDF
    Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology

    Conduit Artery Photoplethysmography and its Applications in the Assessment of Hemodynamic Condition

    Get PDF
    Elektroniskā versija nesatur pielikumusPromocijas darbā ir izstrādāta maģistrālo artēriju fotopletizmogrāfijas (APPG) metode hemodinamisko parametru novērtējumam. Pretstatot referentām metodēm, demonstrēta iespēja iegūt arteriālo elasticitāti raksturojošus parametrus, izmantojot APPG signāla formas analīzi (atvasinājuma un signāla formas aproksimācijas parametri) un ar APPG iegūtu pulsa izplatīšanās ātrumu unilaterālā gultnē. Izstrādāta APPG reģistrācijas standartizācija, mērījuma laikā nodrošinot optimālo sensora piespiedienu. Šis paņēmiens validēts ārējās ietekmes (sensora piespiediens) un hemodinamisko stāvokļu (perifērā vaskulārā pretestība) izmaiņās femorālā APPG signālā, identificējot būtiskākos faktorus APPG pielietojumos. Veikta APPG validācija asinsrites fizioloģijas un preklīniskā pētījumā demonstrējot APPG potenciālu pētniecībā un diagnostikā. Izstrādāts pulsa formas parametrizācijas paņēmiens, saistot fizioloģiskās un aproksimācijas modeļa komponentes. Atslēgas vārdi: maģistrālā artērija, fotopletizmogrāfija, arteriālā elasticitāte, metodes standartizācija, pulsa formas kvantifikācija, vazomocija, sepseThe doctoral thesis features the development of a conduit artery photoplethysmography technique (APPG) for the evaluation of hemodynamic parameters. Contrasting referent methods, the work demonstrates the possibility to receive parameters characterizing the arterial stiffness by means of APPG waveform analysis (derivation and waveform approximation parameters) and APPG obtained pulse wave velocity in a unilateral vascular bed. In this work APPG standardization technique was developed providing optimal probe contact pressure conditions. It was validated by altering the external factors (probe contact pressure) and hemodynamic conditions (peripheral vascular resistance) on the femoral APPG waveform identifying the key factors in APPG applications. The APPG validation in blood circulation physiology and a pre-clinical trial was performed demonstrating APPG potential in the extension of applications. An arterial waveform parameterization was developed relating the physiological wave to approximation model components. Keywords: conduit artery, photoplethysmography, arterial stiffness, method standardization, waveform parametrization, vasomotion, sepsi

    Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life

    Get PDF
    The photoplethysmographic (PPG) signal has been applied in various research fields, with promising results for its future clinical application. However, there are several sources of variability that, if not adequately controlled, can hamper its application in pervasive monitoring contexts. This study assessed and characterized the impact of several sources of variability, such as physical activity, age, sex, and health state on PPG signal quality and PPG waveform parameters (Rise Time, Pulse Amplitude, Pulse Time, Reflection Index, Delta T, and DiastolicAmplitude). We analyzed 31 24 h recordings by as many participants (19 healthy subjects and 12 oncological patients) with a wristband wearable device, selecting a set of PPG pulses labeled with three different quality levels. We implemented a Multinomial Logistic Regression (MLR) model to evaluate the impact of the aforementioned factors on PPG signal quality. We then extracted six parameters only on higher-quality PPG pulses and evaluated the influence of physical activity, age, sex, and health state on these parameters with Generalized Linear Mixed Effects Models (GLMM). We found that physical activity has a detrimental effect on PPG signal quality quality (94% of pulses with good quality when the subject is at rest vs. 9% during intense activity), and that health state affects the percentage of available PPG pulses of the best quality (at rest, 44% for healthy subjects vs. 13% for oncological patients). Most of the extracted parameters are influenced by physical activity and health state, while age significantly impacts two parameters related to arterial stiffness. These results can help expand the awareness that accurate, reliable information extracted from PPG signals can be reached by tackling and modeling different sources of inaccuracy

    Smart garment fabrics to enable non-contact opto-physiological monitoring

    Get PDF
    Imaging photoplethysmography (iPPG) is an emerging technology used to assess microcirculation and cardiovascular signs by collecting backscattered light from illuminated tissue using optical imaging sensors. The aim of this study was to study how effective smart garment fabrics could be capturing physiological signs in a non-contact mode. The present work demonstrates a feasible approach of, instead of using conventional high-power illumination sources, integrating a grid of surface-mounted light emitting diodes (LEDs) into cotton fabric to spotlight the region of interest (ROI). The green and the red LEDs (525 and 660 nm) placed on a small cotton substrate were used to locally illuminate palm skin in a dual-wavelength iPPG setup, where the backscattered light is transmitted to a remote image sensor through the garment fabric. The results show that the illuminations from both wavelength LEDs can be used to extract heart rate (HR) reaching an accuracy of 90% compared to a contact PPG probe. Stretching the fabric over the skin surface alters the morphology of iPPG signals, demonstrating a significantly higher pulsatile amplitude in both channels of green and red illuminations. The skin compression by the fabric could be potentially utilised to enhance the penetration of illumination into cutaneous microvascular beds. The outcome could lead a new avenue of non-contact opto-physiological monitoring and assessment with functional garment fabrics

    Camera-based assessment of cutaneous perfusion strength in a clinical setting

    Get PDF
    Objective. After skin flap transplants, perfusion strength monitoring is essential for the early detection of tissue perfusion disorders and thus to ensure the survival of skin flaps. Camera-based photoplethysmography (cbPPG) is a non-contact measurement method, using video cameras and ambient light, which provides spatially resolved information about tissue perfusion. It has not been researched yet whether the measurement depth of cbPPG, which is limited by the penetration depth of ambient light, is sufficient to reach pulsatile vessels and thus to measure the perfusion strength in regions that are relevant for skin flap transplants. Approach. We applied constant negative pressure (compared to ambient pressure) to the anterior thighs of 40 healthy subjects. Seven measurements (two before and five up to 90 min after the intervention) were acquired using an RGB video camera and photospectrometry simultaneously. We investigated the performance of different algorithmic approaches for perfusion strength assessment, including the signal-to-noise ratio (SNR), its logarithmic components logS and logN, amplitude maps, and the amplitude height of alternating and direct signal components. Main results. We found strong correlations of up to r = 0.694 (p < 0.001) between photospectrometric measurements and all cbPPG parameters except SNR when using the green color channel. The transfer of cbPPG signals to POS, CHROM, and O3C did not lead to systematic improvements. However, for direct signal components, the transformation to O3C led to correlations of up to r = 0.744 (p < 0.001) with photospectrometric measurements. Significance. Our results indicate that a camera-based perfusion strength assessment in tissue with deep-seated pulsatile vessels is possible
    corecore