17,572 research outputs found

    Fault tolerant model predictive control of open channels

    Get PDF
    Automated control of water systems (irrigation canals, navigation canals, rivers etc.) relies on the measured data. The control action is calculated, in case of feedback controller, directly from the on-line measured data. If the measured data is corrupted, the calculated control action will have a different effect than it is desired. Therefore, it is crucial that the feedback controller receives good quality measurement data. On-line fault detection techniques can be applied in order to detect the faulty data and correct it. After the detection and correction of the sensor data, the controller should be able to still maintain the set point of the system. In this paper this principle using the sensor fault masking is applied to model predictive control of open channels. A case study of a reach of the northwest of the inland navigation network of France is presented. Model predictive control and water level sensor masking is applied.Peer ReviewedPostprint (published version

    Reliable fault-tolerant model predictive control of drinking water transport networks

    Get PDF
    This paper proposes a reliable fault-tolerant model predictive control applied to drinking water transport networks. After a fault has occurred, the predictive controller should be redesigned to cope with the fault effect. Before starting to apply the fault-tolerant control strategy, it should be evaluated whether the predictive controller will be able to continue operating after the fault appearance. This is done by means of a structural analysis to determine loss of controllability after the fault complemented with feasibility analysis of the optimization problem related to the predictive controller design, so as to consider the fault effect in actuator constraints. Moreover, by evaluating the admissibility of the different actuator-fault configurations, critical actuators regarding fault tolerance can be identified considering structural, feasibility, performance and reliability analyses. On the other hand, the proposed approach allows a degradation analysis of the system to be performed. As a result of these analyses, the predictive controller design can be modified by adapting constraints such that the best achievable performance with some pre-established level of reliability will be achieved. The proposed approach is tested on the Barcelona drinking water transport network.Postprint (author's final draft

    Set-valued observer-based active fault-tolerant model predictive control

    Get PDF
    This paper proposes an integrated actuator and sensor active fault-tolerant model predictive control scheme. In this scheme, fault detection is implemented by using a set-valued observer, fault isolation (FI) is performed by set manipulations, and fault-tolerant control is carried out through the design of a robust model predictive control law. In this paper, a set-valued observer is used to passively complete the fault detection task, while FI is actively performed by making use of the constraint-handling capability of robust model predictive control. The set-valued observer is chosen to implement fault detection and isolation (FDI) because of its simple mathematical structure that is not affected by the type of faults such as sensor, actuator, and system-structural faults. This means that only one set-valued observer is needed to monitor all considered actuator and sensor statuses (health and fault) and to carry out the fault detection and isolation task instead of using a bank of observers (each observer matching a health/fault status). Furthermore, in the proposed scheme, the advantage of robust model predictive control is that it can effectively deal with system constraints, disturbances, and noises and allow to implement an active FI strategy, which can improve FI sensitivity when compared with the passive FI methods. Finally, a case study based on the well-known two-tank system is used to illustrate the effectiveness of the proposed fault-tolerant model predictive control scheme.Peer ReviewedPostprint (author's final draft

    Sensor-fault tolerance using robust MPC with set-based state estimation and active fault isolation

    Get PDF
    In this paper, a sensor fault-tolerant control (FTC) scheme using robust model predictive control (MPC) and set theoretic fault detection and isolation (FDI) is proposed. The MPC controller is used to both robustly control the plant and actively guarantee fault isolation (FI). In this scheme, fault detection (FD) is passive by interval observers, while fault isolation (FI) is active by MPC. The advantage of the proposed approach consists in using MPC to actively decouple the effect of sensor faults on the outputs such that one output component only corresponds to one sensor fault in terms of FI, which can utilize the feature of sensor faults for FI. A numerical example is used to illustrate the effectiveness of the proposed scheme.Postprint (author’s final draft

    Robust MPC for actuator-fault tolerance using set-based passive fault detection and active fault isolation

    Get PDF
    In this paper, an actuator fault-tolerant control (FTC) scheme is proposed, which is based on tube-based model predictive control (MPC) and set-theoretic fault detection and isolation (FDI). As a robust MPC technique, tube-based MPC, can effectively deal with system constraints and uncertainties with relatively low computational complexity. Set-based FDI can robustly detect and isolate actuator faults. Here, fault detection (FD) is passive by invariant sets, while fault isolation (FI) is active by tubes. Using the constraint-handling ability of MPC controllers, an active FI approach is implemented. A numerical example illustrates the effectiveness of the proposed approach.Postprint (author’s final draft

    Fault tolerant model predictive control of open channels

    Get PDF
    Trabajo presentado a la USCID Conference on Planning, Operation and Automation of Irrigation Delivery Systems celebrada en Phoenix, Arizona (US) del 2 al 5 de diciembre de 2014.Automated control of water systems (irrigation canals, navigation canals, rivers etc.) relies on the measured data. The control action is calculated, in case of feedback controller, directly from the on-line measured data. If the measured data is corrupted, the calculated control action will have a different effect than it is desired. Therefore, it is crucial that the feedback controller receives good quality measurement data. On-line fault detection techniques can be applied in order to detect the faulty data and correct it. After the detection and correction of the sensor data, the controller should be able to still maintain the set point of the system. In this paper this principle using the sensor fault masking is applied to model predictive control of open channels. A case study of a reach of the northwest of the inland navigation network of France is presented. Model predictive control and water level sensor masking is applied.Peer Reviewe

    Fault tolerant control using Gaussian processes and model predictive control

    Get PDF
    Abstract Essential ingredients for fault-tolerant control are the ability to represent system behaviour following the occurrence of a fault, and the ability to exploit this representation for deciding control actions. Gaussian processes seem to be very promising candidates for the first of these, and model predictive control has a proven capability for the second. We therefore propose to use the two together to obtain fault-tolerant control functionality. Our proposal is illustrated by several reasonably realistic examples drawn from flight control.This research was supported by EU Framework Programme 7, project 314544, RECONFIGURE: Reconfiguration of Control in Flight for Integral Global Upset Recovery, as well as the China Scholarship Council and the Cambridge Overseas Trust.This is the final published version. It first appeared at http://www.degruyter.com/view/j/amcs.2015.25.issue-1/amcs-2015-0010/amcs-2015-0010.xml

    A dynamic prognosis algorithm in distributed fault tolerant model predictive control

    Get PDF
    This paper presents a dynamic prognosis algorithm in distributed fault tolerant model predictive control (DFTMPC). The dynamic prognosis, which means predicting the trajectories of process variables under distributed model predictive control, is performed when a fault is diagnosed and several candidate reconfigured controls are proposed. Then, the dynamic prognosis is utilized to check whether the candidate reconfigured controls are able to drive the system to the new operating conditions and to evaluate the performance during the transition period. Thus, the most suitable candidate reconfigured controller is selected and its feasibility is ensured without using a Lyapunov function that is difficult to obtain for large-scale systems. On the other hand, the on-line computation burden of the prognosis algorithm is moderate under the assumption that the sets of active constraints in non-faulty subsystems remain the same as they are at the nominal operating conditions. Thus, the dynamic prognosis for DMPC is aimed to improve the applicability of the existing fault tolerant methods to large-scale systems.Peer reviewe

    Model predictive Direct Flux Vector Control of multi three-phase induction motor drives

    Get PDF
    A model predictive control scheme for multiphase induction machines, configured as multi three-phase structures, is proposed in this paper. The predictive algorithm uses a Direct Flux Vector Control scheme based on a multi three-phase approach, where each three-phase winding set is independently controlled. In this way, the fault tolerant behavior of the drive system is improved. The proposed solution has been tested with a multi-modular power converter feeding a six-phase asymmetrical induction machine (10kW, 6000 rpm). Complete details about the predictive control scheme and adopted flux observer are included. The experimental validation in both generation and motoring mode is reported, including post open-winding fault operations. The experimental results demonstrate the feasibility of the proposed drive solution
    • …
    corecore