    Datacenter Traffic Control: Understanding Techniques and Trade-offs

    Get PDF
    Datacenters provide cost-effective and flexible access to scalable compute and storage resources necessary for today's cloud computing needs. A typical datacenter is made up of thousands of servers connected with a large network and usually managed by one operator. To provide quality access to the variety of applications and services hosted on datacenters and maximize performance, it deems necessary to use datacenter networks effectively and efficiently. Datacenter traffic is often a mix of several classes with different priorities and requirements. This includes user-generated interactive traffic, traffic with deadlines, and long-running traffic. To this end, custom transport protocols and traffic management techniques have been developed to improve datacenter network performance. In this tutorial paper, we review the general architecture of datacenter networks, various topologies proposed for them, their traffic properties, general traffic control challenges in datacenters and general traffic control objectives. The purpose of this paper is to bring out the important characteristics of traffic control in datacenters and not to survey all existing solutions (as it is virtually impossible due to massive body of existing research). We hope to provide readers with a wide range of options and factors while considering a variety of traffic control mechanisms. We discuss various characteristics of datacenter traffic control including management schemes, transmission control, traffic shaping, prioritization, load balancing, multipathing, and traffic scheduling. Next, we point to several open challenges as well as new and interesting networking paradigms. At the end of this paper, we briefly review inter-datacenter networks that connect geographically dispersed datacenters which have been receiving increasing attention recently and pose interesting and novel research problems.Comment: Accepted for Publication in IEEE Communications Surveys and Tutorial

    Power Management Techniques for Data Centers: A Survey

    Full text link
    With growing use of internet and exponential growth in amount of data to be stored and processed (known as 'big data'), the size of data centers has greatly increased. This, however, has resulted in significant increase in the power consumption of the data centers. For this reason, managing power consumption of data centers has become essential. In this paper, we highlight the need of achieving energy efficiency in data centers and survey several recent architectural techniques designed for power management of data centers. We also present a classification of these techniques based on their characteristics. This paper aims to provide insights into the techniques for improving energy efficiency of data centers and encourage the designers to invent novel solutions for managing the large power dissipation of data centers.Comment: Keywords: Data Centers, Power Management, Low-power Design, Energy Efficiency, Green Computing, DVFS, Server Consolidatio

    SymbioCity: Smart Cities for Smarter Networks

    Get PDF
    The "Smart City" (SC) concept revolves around the idea of embodying cutting-edge ICT solutions in the very fabric of future cities, in order to offer new and better services to citizens while lowering the city management costs, both in monetary, social, and environmental terms. In this framework, communication technologies are perceived as subservient to the SC services, providing the means to collect and process the data needed to make the services function. In this paper, we propose a new vision in which technology and SC services are designed to take advantage of each other in a symbiotic manner. According to this new paradigm, which we call "SymbioCity", SC services can indeed be exploited to improve the performance of the same communication systems that provide them with data. Suggestive examples of this symbiotic ecosystem are discussed in the paper. The dissertation is then substantiated in a proof-of-concept case study, where we show how the traffic monitoring service provided by the London Smart City initiative can be used to predict the density of users in a certain zone and optimize the cellular service in that area.Comment: 14 pages, submitted for publication to ETT Transactions on Emerging Telecommunications Technologie

    EVEREST IST - 2002 - 00185 : D23 : final report

    Get PDF
    Deliverable pĂşblic del projecte europeu EVERESTThis deliverable constitutes the final report of the project IST-2002-001858 EVEREST. After its successful completion, the project presents this document that firstly summarizes the context, goal and the approach objective of the project. Then it presents a concise summary of the major goals and results, as well as highlights the most valuable lessons derived form the project work. A list of deliverables and publications is included in the annex.Postprint (published version

    TimeTrader: Exploiting Latency Tail to Save Datacenter Energy for On-line Data-Intensive Applications

    Get PDF
    Datacenters running on-line, data-intensive applications (OLDIs) consume significant amounts of energy. However, reducing their energy is challenging due to their tight response time requirements. A key aspect of OLDIs is that each user query goes to all or many of the nodes in the cluster, so that the overall time budget is dictated by the tail of the replies' latency distribution; replies see latency variations both in the network and compute. Previous work proposes to achieve load-proportional energy by slowing down the computation at lower datacenter loads based directly on response times (i.e., at lower loads, the proposal exploits the average slack in the time budget provisioned for the peak load). In contrast, we propose TimeTrader to reduce energy by exploiting the latency slack in the sub- critical replies which arrive before the deadline (e.g., 80% of replies are 3-4x faster than the tail). This slack is present at all loads and subsumes the previous work's load-related slack. While the previous work shifts the leaves' response time distribution to consume the slack at lower loads, TimeTrader reshapes the distribution at all loads by slowing down individual sub-critical nodes without increasing missed deadlines. TimeTrader exploits slack in both the network and compute budgets. Further, TimeTrader leverages Earliest Deadline First scheduling to largely decouple critical requests from the queuing delays of sub- critical requests which can then be slowed down without hurting critical requests. A combination of real-system measurements and at-scale simulations shows that without adding to missed deadlines, TimeTrader saves 15-19% and 41-49% energy at 90% and 30% loading, respectively, in a datacenter with 512 nodes, whereas previous work saves 0% and 31-37%.Comment: 13 page
    • …