3,799 research outputs found
The Essential Role and the Continuous Evolution of Modulation Techniques for Voltage-Source Inverters in the Past, Present, and Future Power Electronics
The cost reduction of power-electronic devices, the increase in their reliability, efficiency, and power capability, and lower development times, together with more demanding application requirements, has driven the development of several new inverter topologies recently introduced in the industry, particularly medium-voltage converters. New more complex inverter topologies and new application fields come along with additional control challenges, such as voltage imbalances, power-quality issues, higher efficiency needs, and fault-tolerant operation, which necessarily requires the parallel development of modulation schemes. Therefore, recently, there have been significant advances in the field of modulation of dc/ac converters, which conceptually has been dominated during the last several decades almost exclusively by classic pulse-width modulation (PWM) methods. This paper aims to concentrate and discuss the latest developments on this exciting technology, to provide insight on where the state-of-the-art stands today, and analyze the trends and challenges driving its future
Analysis and mitigation of dead time harmonics in the single-phase full-bridge PWM converters with repetitive controllers
In order to prevent the power switching devices (e.g., the Insulated-Gate-Bipolar-Transistor, IGBT) from shoot through in voltage source converters during a switching period, the dead time is added either in the hardware driver circuits of the IGBTs or implemented in software in Pulse-Width Modulation (PWM) schemes. Both solutions will contribute to a degradation of the injected current quality. As a consequence, the harmonics induced by the dead time (referred to as "dead time harmonics" hereafter) have to be compensated in order to achieve a satisfactory current quality as required by standards. In this paper, the emission mechanism of dead time harmonics in single-phase PWM inverters is thus presented considering the modulation schemes in details. More importantly, a repetitive controller has been adopted to eliminate the dead time effect in single-phase grid-connected PWM converters. The repetitive controller has been plugged into a proportional resonant-based
fundamental current controller so as to mitigate the dead time harmonics and also maintain the control of the fundamental frequency grid current in terms of dynamics. Simulations and experiments are provided, which confirm that the repetitive controller can effectively compensate the dead time harmonics and other low-order distortions, and also it is a simple method without hardware modifications
Plug and Play DC-DC Converters for Smart DC Nanogrids with Advanced Control Ancillary Services
This paper gives a general view of the control possibilities for dc-dc converters in dc nanogrids. A widely adopted control method is the droop control, which is able to achieve proportional load sharing among multiple sources and to stabilize the voltage of the dc distribution bus. Based on the droop control, several advanced control functions can be implemented. For example, power-based droop controllers allow dc-dc converters to operate with power flow control or droop control, whether the hosting nanogrid is operating connected to a strong upstream grid or it is operating autonomously (i.e., islanded). Converters can also be equipped with various supporting functions. Functions that are expected to play a crucial role in nanogrids that fully embrace the plug-and-play paradigm are those aiming at the monitoring and tuning of the key performance indices of the control loops. On-line stability monitoring tools respond to this need, by continuously providing estimates of the stability margins of the loops of interest; self- tuning can be eventually achieved on the basis of the obtained estimates. These control solutions can significantly enhance the operation and the plug-and-play feature of dc nanogrids, even with a variable number of hosted converters. Experimental results are reported to show the performance of the control approaches
Back-to-back Converter Control of Grid-connected Wind Turbine to Mitigate Voltage Drop Caused by Faults
Power electronic converters enable wind turbines, operating at variable
speed, to generate electricity more efficiently. Among variable speed operating
turbine generators, permanent magnetic synchronous generator (PMSG) has got
more attentions due to low cost and maintenance requirements. In addition, the
converter in a wind turbine with PMSG decouples the turbine from the power
grid, which favors them for grid codes. In this paper, the performance of
back-to-back (B2B) converter control of a wind turbine system with PMSG is
investigated on a faulty grid. The switching strategy of the grid side
converter is designed to improve voltage drop caused by the fault in the grid
while the maximum available active power of wind turbine system is injected to
the grid and the DC link voltage in the converter is regulated. The methodology
of the converter control is elaborated in details and its performance on a
sample faulty grid is assessed through simulation
A unified analysis of PWM converters in discontinuous modes
Three discontinuous operating modes of PWM (pulsewidth modulated) converters are considered: the discontinuous inductor current mode (DICM), the discontinuous capacitor voltage mode (DCVM), and a previously unidentified mode called the discontinuous quasi-resonant mode (DQRM). DC and small-signal AC analyses are applicable to all basic PWM converter topologies. Any particular topology is taken into account via its DC conversion ratio in the continuous conduction mode. The small-signal model is of the same order as the state-space averaged model for the continuous mode, and it offers improved predictions of the low-frequency dynamics of PWM converters in the discontinuous modes. It is shown that converters in discontinuous modes exhibit lossless damping similar to the effect of the current-mode programming
Recommended from our members
Harmonic current extraction of shunt active power filter based on prediction current technique - Hysteresis PWM
Due to the wide spread of power electronics equipment in modern electrical systems, the increase of the
harmonics disturbance in the ac mains currents has became a major concern due to the adverse effects on all
analysis and simulation using MATLAB-SIMULINK of a three-phase shunt active equipment. This paper presents the Shunt Active Power Filter (SAPF) to compensate the generated harmonics by 3-phase Rectifier Bridge fed R-L load. The harmonic current extraction is based on prediction current extraction technique -hysteresis PWM generation pattern
Multiphase induction motor drives - a technology status review
The area of multiphase variable-speed motor drives in general and multiphase induction motor drives in particular has experienced a substantial growth since the beginning of this century. Research has been conducted worldwide and numerous interesting developments have been reported in the literature. An attempt is made to provide a detailed overview of the current state-of-the-art in this area. The elaborated aspects include advantages of multiphase induction machines, modelling of multiphase induction machines, basic vector control and direct torque control schemes and PWM control of multiphase voltage source inverters. The authors also provide a detailed survey of the control strategies for five-phase and asymmetrical six-phase induction motor drives, as well as an overview of the approaches to the design of fault tolerant strategies for post-fault drive operation, and a discussion of multiphase multi-motor drives with single inverter supply. Experimental results, collected from various multiphase induction motor drive laboratory rigs, are also included to facilitate the understanding of the drive operatio
Direct usage of photovoltaic solar panels to supply a freezer motor with variable DC input voltage
In this paper, a single-phase photovoltaic (PV) inverter fed by a boost converter to supply a freezer motor with variable DC input is investigated. The proposed circuit has two stages. Firstly, the DC output of the PV panel that varies between 150 and 300 V will be applied to the boost converter. The boost converter will boost the input voltage to a fixed 300 V DC. Next, this voltage is supplied to the single-phase full-bridge inverter to obtain 230 V AC. In the end, The output of the inverter will feed a freezer motor. The PV panels can be stand-alone or grid-connected. The grid-connected PV is divided into two categories, such as with a transformer and without a transformer, a transformer type has galvanic isolation resulting in increasing the security and also provides no further DC current toward the grid, but it is expensive, heavy and bulky. The transformerless type holds high efficiency and it is cheaper, but it suffers from leakage current between PV and the grid. This paper proposes a stand-alone direct use of PV to supply a freezer; therefore, no grid connection will result in no leakage current between the PV and Grid. The proposed circuit has some features such as no filtering circuit at the output of the inverter, no battery in the system, DC-link instead of AC link that reduces no-loads, having a higher efficiency, and holding enough energy in the DC-link capacitor to get the motor started. The circuit uses no transformers, thus, it is cheaper and has a smaller size. In addition, the system does not require a complex pulse width modulation (PWM) technique, because the motor can operate with a pulsed waveform. The control strategy uses the PWM signal with the desired timing. With this type of square wave, the harmonics (5th and 7th) of the voltage are reduced. The experimental and simulation results are presented to verify the feasibility of the proposed strategy
Power Factor Correction Using Single Stage Discontinuous Conduction Mode Booster Rectifier
A single stage three-phase power factor correction circuit using a boost input current
shaper has been described in both simulation and experimental work. To reduce the
cost and avoid complexity the boost dc-to-dc converter is operated in discontinuous
conduction mode using only one active switch. A low cost harmonic injection
method for single switch three-phase DCM boost rectifiers has been simulated and
tested. In this method, a periodic voltage which is proportional to the inverted ac
component of the rectified three-phase line-to-line input voltage is injected in the
control circuit to vary the duty cycle of the rectifier switch within a line cycle, so that
the fifth-order harmonics of the input current is reduced to meet THD<10%
requirement.The analysis of the injected signal and modified harmonic currents of the rectifier has
been presented and verified on a laboratory prototype. Based on the equivalent multimodel
an average small signal model of the boost power stage is developed and
verified by simulation. The variations of the small signal model against load are
demonstrated, and the compensator designed for constant switching frequency PWM
is discussed. The simulated results show that at light load, the dominant pole of the
control-to-output transfer function approaches the origin and causes more phase
delay, complicating the control design circuit. To avoid the no load case and simplify
the control design, a dummy is added.
The single stage three-phase boost power factor correction with improved input
current distortion has been simulated using OrCad release 9.1 software. The results
show there is an agreement between the simulation and experimental work
- …