106 research outputs found

    Was the Scanner Calibration Slide used for its intended purpose?

    Get PDF
    In the article, Scanner calibration revisited, BMC Bioinformatics 2010, 11:361, Dr. Pozhitkov used the Scanner Calibration Slide, a key product of Full Moon BioSystems to generate data in his study of microarray scanner PMT response and proposed a mathematic model for PMT response [1]. In the end, the author concluded that "Full Moon BioSystems calibration slides are inadequate for performing calibration," and recommended "against using these slides." We found these conclusions are seriously flawed and misleading, and his recommendation against using the Scanner Calibration Slide was not properly supported

    A Revised Design for Microarray Experiments to Account for Experimental Noise and Uncertainty of Probe Response

    Get PDF
    Background Although microarrays are analysis tools in biomedical research, they are known to yield noisy output that usually requires experimental confirmation. To tackle this problem, many studies have developed rules for optimizing probe design and devised complex statistical tools to analyze the output. However, less emphasis has been placed on systematically identifying the noise component as part of the experimental procedure. One source of noise is the variance in probe binding, which can be assessed by replicating array probes. The second source is poor probe performance, which can be assessed by calibrating the array based on a dilution series of target molecules. Using model experiments for copy number variation and gene expression measurements, we investigate here a revised design for microarray experiments that addresses both of these sources of variance. Results Two custom arrays were used to evaluate the revised design: one based on 25 mer probes from an Affymetrix design and the other based on 60 mer probes from an Agilent design. To assess experimental variance in probe binding, all probes were replicated ten times. To assess probe performance, the probes were calibrated using a dilution series of target molecules and the signal response was fitted to an adsorption model. We found that significant variance of the signal could be controlled by averaging across probes and removing probes that are nonresponsive or poorly responsive in the calibration experiment. Taking this into account, one can obtain a more reliable signal with the added option of obtaining absolute rather than relative measurements. Conclusion The assessment of technical variance within the experiments, combined with the calibration of probes allows to remove poorly responding probes and yields more reliable signals for the remaining ones. Once an array is properly calibrated, absolute quantification of signals becomes straight forward, alleviating the need for normalization and reference hybridizations

    Revision of the nonequilibrium thermal dissociation and stringent washing approaches for identification of mixed nucleic acid targets by microarrays

    Get PDF
    Microarray experiments typically involve washing steps that remove hybridized nonspecific targets with the purpose of improving the signal-to-noise ratio. The quality of washing ultimately affects downstream analysis of the microarray and interpretation. The paucity of fundamental studies directed towards understanding the dissociation of mixed targets from microarrays makes the development of meaningful washing/dissociation protocols difficult. To fill the void, we examined activation energies and preexponential coefficients of 47 perfect match (PM) and double-mismatch (MM) duplex pairs to discover that there was no statistical difference between the kinetics of the PM and MM duplexes. Based on these findings, we evaluated the nonequilibrium thermal dissociation (NTD) approach, which has been used to identify specific microbial targets in mixed target samples. We found that the major premises for various washing protocols and the NTD approach might be seriously compromised because: (i) nonspecific duplexes do not always dissociate before specific ones, and (ii) the relationship between dissociation rates of the PM and MM duplexes depends on temperature and duplex sequence. Specifically for the NTD, we show that previously suggested use of reference curves, indices of curves and temperature ramps lead to erroneous conclusions

    A new procedure for microarray experiments to account for experimental noise and the uncertainty of probe response

    Get PDF
    Although microarrays are routine analysis tools in biomedical research, theystill yield noisy output that often requires experimental confirmation. Manystudies have aimed at optimizing probe design and statistical analysis totackle this problem. However, less emphasis has been placed on controlling thenoise inherent to the experimental approach. To address this problem, weinvestigate here a procedure that controls for such experimental variance andcombine it with an assessment of probe performance. Two custom arrays were usedto evaluate the procedure: one based on 25mer probes from an Affymetrix designand the other based on 60mer probes from an Agilent design. To assessexperimental variance, all probes were replicated ten times. To assess probeperformance, the probes were calibrated using a dilution series of targetmolecules and the signal response was fitted to an absorption model. We foundthat significant variance of the signal could be controlled by averaging acrossprobes and removing probes that are nonresponsive. Thus, a more reliable signalcould be obtained using our procedure than conventional approaches. We suggestthat once an array is properly calibrated, absolute quantification of signalsbecomes straight forward, alleviating the need for normalization and referencehybridizations.<br

    Beyond Affymetrix Arrays: Expanding the Set of Known Hybridization Isotherms and Observing Pre-Wash Signal Intensities

    Get PDF
    Microarray hybridization studies have attributed the nonlinearity of hybridization isotherms to probe saturation and post-hybridization washing. Both processes are thought to distort \u27true\u27 target abundance because immobilized probes are saturated with excess target and stringent washing removes loosely bound targets. Yet the paucity of studies aimed at understanding hybridization and dissociation makes it difficult to align physicochemical theory to microarray results. To fill the void, we first examined hybridization isotherms generated on different microarray platforms using a ribosomal RNA target and then investigated hybridization signals at equilibrium and after stringent wash. Hybridization signal at equilibrium was achieved by treating the microarray with isopropanol, which prevents nucleic acids from dissolving into solution. Our results suggest that (i) the shape of hybridization isotherms varied by microarray platform with some being hyperbolic or linear, and others following a power-law; (ii) at equilibrium, fluorescent signal of different probes hybridized to the same target were not similar even with excess of target and (iii) the amount of target removed by stringent washing depended upon the hybridization time, the probe sequence and the presence/absence of nonspecific targets. Possible physicochemical interpretations of the results and future studies are discussed

    Datasets used to discover the microbial signatures of oral dysbiosis, periodontitis and edentulism in humans

    Get PDF
    AbstractThis article provides supporting data for the research article ‘Microbial Signatures of Oral Dysbiosis, Periodontitis and Edentulism Revealed by Gene Meter Methodology’ (M.C. Hunter, A.E. Pozhitkov, P.A. Noble, 2016) [1]. In that article, we determined the microbial abundance signatures for patient with periodontics, edentulism, or health using Gene Meter Technology. Here we provide the data used to make the DNA microarray and the resulting microbial abundance data that was determined using the calibrated probes and the 16S rRNA genes harvested from patients. The first data matrix contains two columns: one is the GenInfo Identifier (GI) numbers of the 16S rRNA gene sequences and the other is the corresponding oral bacterial taxonomy. The probes were then screened for redundancy and if they were found to be unique, they were synthesized onto the surface of the DNA microarrays. The second data matrix consists of the abundances of the 576 16S rRNA genes that was determined using the median value of all individual calibrated probes targeting each gene. The data matrix consists of 16 columns and 576 rows, with the columns representing the 16 patients and the rows representing 576 different oral microorganisms. The third data matrix consists of the abundances of 567 16S rRNA genes determined using the calibrated abundance of all aggregated probes targeting the same 16S rRNA gene. The data matrix of the aggregated probes consists of 16 samples and 567 rows

    Constructing a fish metabolic network model

    Get PDF
    We report the construction of a genome-wide fish metabolic network model, MetaFishNet, and its application to analyzing high throughput gene expression data. This model is a stepping stone to broader applications of fish systems biology, for example by guiding study design through comparison with human metabolism and the integration of multiple data types. MetaFishNet resources, including a pathway enrichment analysis tool, are accessible at http://metafishnet.appspot.com

    Physico-chemical foundations underpinning microarray and next-generation sequencing experiments

    Get PDF
    Hybridization of nucleic acids on solid surfaces is a key process involved in high-throughput technologies such as microarrays and, in some cases, next-generation sequencing (NGS). A physical understanding of the hybridization process helps to determine the accuracy of these technologies. The goal of a widespread research program is to develop reliable transformations between the raw signals reported by the technologies and individual molecular concentrations from an ensemble of nucleic acids. This research has inputs from many areas, from bioinformatics and biostatistics, to theoretical and experimental biochemistry and biophysics, to computer simulations. A group of leading researchers met in Ploen Germany in 2011 to discuss present knowledge and limitations of our physico-chemical understanding of high-throughput nucleic acid technologies. This meeting inspired us to write this summary, which provides an overview of the state-of-the-art approaches based on physico-chemical foundation to modeling of the nucleic acids hybridization process on solid surfaces. In addition, practical application of current knowledge is emphasized
    corecore