205 research outputs found

    Hemodynamic Monitoring Using A Pulse Counter Vigileo Flotrac Cardiac Output System In Transapical Off-Pump Minimally Invasive Mitral Valve Repair

    Get PDF
    The aim of this study was to present our anesthetic management and early hemodynamic recovery after transapical off-pump neochords implantation. Observational prospective study. The perioperative records of 13 patients who underwent mitral valve repair using the Neochord DS1000 system were analyzed. Hemodynamic measurements recorded with the Vigileo Flotrac invasive arterial cardiac output system were evaluated. Thirteen patients were included in the study. Transfusions of a total of 2 U of erythrocytes and 11 U of plasma were performed. After Neochord implantation, the mean cardiac output increased at a statistically significant level according to the values measured after induction p = 0.003. Increased cardiac output measurement after placement of the neochordaes and elimination of insufficiency have emerged as indications of early hemodynamic recover

    Helicobacter pylori Seropositivity and Stool Antigen in Patients With Hyperemesis Gravidarum

    Get PDF
    The objective of this paper is to investigate whether Helicobacter pylori is an etiologic factor in hyperemesis gravidarum. Thirty one patients with hyperemesis gravidarum and twenty nine pregnant controls without hyperemesis gravidarum were included in this prospective study. All pregnant women were examined both for Helicobacter pylori serum immunoglobulin G antibodies (HpIgG Ab), showing chronic infection, and Helicobacter pylori stool antigens (HpSA), showing active gastrointestinal colonization. Chi-square and Student t tests were used accordingly for statistical analysis. Helicobacter pylori seropositivity was 67.7% in the patients with hyperemesis gravidarum and 79.3% in the control group (χ(2) = 1.02, P = .31). HpSA was detected in 22.6% of patients with hyperemesis gravidarum, whereas 6.9% of patients in the control group. The difference was not statistically significant (χ(2) = 2.89, P = .08). In this study, no relation was found between Helicobacter pylori and hyperemesis gravidarum. The low social status of women in both groups could be one of the reasons for the high prevalence of Hp infection

    Royal Jelly Modulates Oxidative Stress and Apoptosis in Liver and Kidneys of Rats Treated with Cisplatin

    Get PDF
    Cisplatin (CDDP) is one of the most active cytotoxic agents in the treatment of cancer and has adverse side effects such as nephrotoxicity and hepatotoxicity. The present study was designed to determine the effects of royal jelly (RJ) against oxidative stress caused by CDDP injury of the kidneys and liver, by measuring tissue biochemical and antioxidant parameters and investigating apoptosis immunohistochemically. Twenty-four Sprague Dawley rats were divided into four groups, group C: control group received 0.9% saline; group CDDP: injected i.p. with cisplatin (CDDP, 7 mg kg−1 body weight i.p., single dose); group RJ: treated for 15 consecutive days by gavage with RJ (300 mg/kg/day); group RJ + CDDP: treated by gavage with RJ 15 days following a single injection of CDDP. Malondialdehyde (MDA) and glutathione (GSH) levels, glutathione S-transferase (GST), glutathione peroxidase (GSH-Px), and superoxide dismutase (SOD) activities were determined in liver and kidney homogenates, and the liver and kidney were also histologically examined. RJ elicited a significant protective effect towards liver and kidney by decreasing the level of lipid peroxidation (MDA), elevating the level of GSH, and increasing the activities of GST, GSH-Px, and SOD. In the immunohistochemical examinations were observed significantly enhanced apoptotic cell numbers and degenerative changes by cisplatin, but these histological changes were lower in the liver and kidney tissues of RJ + CDDP group. Besides, treatment with RJ lead to an increase in antiapoptotic activity hepatocytes and tubular epithelium. In conclusion, RJ may be used in combination with cisplatin in chemotherapy to improve cisplatin-induced oxidative stress parameters and apoptotic activity

    a controlled study design

    Get PDF
    This study aimed to analyse the impact of an 8-week core strength training (CST) programme in youth karate practitioners on core endurance, agility, flexibility, sprinting, jumping, and kick performance. This study followed a randomized parallel design. Twenty-nine participants (age: 12.86 ± 0.81 years old; height: 152.55 ± 10.37 cm; weight: 42.93 ± 8.85 kg) were allocated to a CST programme (n = 16) performed thrice weekly or to a control group (n = 13) only performing the sport-specific (karate) training. Participants were assessed three times (baseline, mid and post-intervention) for the following tests: (i) flexor endurance test (FET); (ii) back extensor test (BET); (iii) lateral musculature test (LMT); (iv) flexibility; (v) chance of direction (COD); (vi) countermovement jump (CMJ); (vii) back muscle strength (BMS); (viii) horizontal jump (LJ); (ix) sprint test; and (x) karate kick test (KKT). Between-group analysis revealed significant advantages for the CST group on the FET (p 0.05). The within-group changes revealed significant improvements in the CST group at flexibility (p = 0.002), COD (p < 0.001), CMJ (p < 0.001), BMS (p < 0.002), 20 m sprint (p = 0.033), and KKT (p < 0.001). In addition, within-group changes in the control group were also significant in flexibility (p = 0.024) and right kick (p < 0.042). We conclude that the CST programme improves core endurance and karate kick performance; however, it is not effective enough for other physical performance parameters in KR practitioners.9E1A-F9DD-3EB8 | Filipe Manuel ClementeN/

    TSCom-Net: Coarse-to-Fine 3D Textured Shape Completion Network

    Get PDF
    Reconstructing 3D human body shapes from 3D partial textured scans remains a fundamental task for many computer vision and graphics applications – e.g., body animation, and virtual dressing. We propose a new neural network architecture for 3D body shape and highresolution texture completion – TSCom-Net – that can reconstruct the full geometry from mid-level to high-level partial input scans. We decompose the overall reconstruction task into two stages – first, a joint implicit learning network (SCom-Net and TCom-Net) that takes a voxelized scan and its occupancy grid as input to reconstruct the full body shape and predict vertex textures. Second, a high-resolution texture completion network, that utilizes the predicted coarse vertex textures to inpaint the missing parts of the partial ‘texture atlas’. A Thorough experimental evaluation on 3DBodyTex.V2 dataset shows that our method achieves competitive results with respect to the state-of-the-art while generalizing to different types and levels of partial shapes. The proposed method has also ranked second in the track1 of SHApe Recovery from Partial textured 3D scans (SHARP [37 , 2]) 2022 1 challenge1

    SHARP Challenge 2023: Solving CAD History and pArameters Recovery from Point clouds and 3D scans. Overview, Datasets, Metrics, and Baselines.

    Get PDF
    peer reviewedRecent breakthroughs in geometric Deep Learning (DL) and the availability of large Computer-Aided Design (CAD) datasets have advanced the research on learning CAD modeling processes and relating them to real objects. In this context, 3D reverse engineering of CAD models from 3D scans is considered to be one of the most sought-after goals for the CAD industry. However, recent efforts assume multiple simplifications limiting the applications in real-world settings. The SHARP Challenge 2023 aims at pushing the research a step closer to the real-world scenario of CAD reverse engineering from 3D scans through dedicated datasets and tracks. In this paper, we define the proposed SHARP 2023 tracks, describe the provided datasets, and propose a set of baseline methods along with suitable evaluation metrics to assess the performance of the track solutions. All proposed datasets along with useful routines and the evaluation metrics are publicly available

    Safety and efficacy of Amplatzer duct occluder II and konar-MF™ VSD occluder in the closure of perimembranous ventricular septal defects in children weighing less than 10 kg

    Get PDF
    IntroductionDevice closure of perimembranous ventricular septal defects (pmVSD) is a successful off-label treatment alternative. We aim to report and compare the outcomes of pmVSD closure in children weighing less than 10 kg using Amplatzer Duct Occluder II (ADOII) and Konar-MF VSD Occluder (MFO) devices.MethodsRetrospective clinical data review of 52 children with hemodynamically significant pmVSD, and sent for transcatheter closure using ADOII and MFO, between January 2018 and January 2023. Baseline, procedural, and follow-up data were compared according to the implanted deviceResultsADOII devices were implanted in 22 children with a median age of 11 months (IQR, 4.1–14.7) and weight of 7.4 kg (IQR, 2.7–9.7). MFO devices were implanted in 30 children with a median age of 11 months (IQR, 4.8–16.6) and weight of 8 kg (IQR, 4.1–9.6). ADOII were implanted (retrograde, 68.1%) in defects with a median left ventricular diameter of 4.6 mm (IQR, 3.8–5.7) and right ventricular diameter of 3.5 mm (IQR, 3.1–4.9) while MFO were implanted (antegrade, 63.3%) in defects with a median left ventricular diameter of 7 mm (IQR, 5.2–11.3) (p &gt; 0.05) and right ventricular diameter of 5 mm (IQR, 2.0, 3.5–6.2) (p &lt; 0.05). The procedural and fluoroscopy times were shorter with the MFO device (p &lt; 0.05). On a median follow-up of 41.2 months (IQR, 19.7–49.3), valvular insufficiency was not observed. One 13-month-old child (6.3 kg) with ADOII developed a complete atrioventricular heart block (CAVB) six months postoperative and required pacemaker implantation. One 11-month-old child (5.9 kg) with MFO developed a CAVB 3 days postoperative and the device was removed. At 6 months post-procedure, only one child with MFO still experiences a minor residual shunt. There was one arterio-venous fistula that resolved spontaneously.ConclusionBoth the MFO and ADOII are effective closure devices in appropriately selected pmVSDs. CAVB can occur with both devices. The MFO is inherently advantageous for defects larger than 6 mm and subaortic rims smaller than 3 mm. In the literature, our series represents the first study comparing the mid-term outcomes of MFO and ADOII devices in children weighing less than 10 kg

    Musculoskeletal manifestations in children with Behçet's syndrome: data from the AIDA Network Behçet's Syndrome Registry

    Get PDF
    This study aims to&nbsp;describe musculoskeletal manifestations (MSM) in children with Behçet's syndrome (BS), their association with other disease manifestations, response to therapy, and long-term prognosis. Data were retrieved from the AIDA Network Behçet's Syndrome Registry. Out of a total of 141 patients with juvenile BS, 37 had MSM at disease onset (26.2%). The median age at onset was 10.0&nbsp;years (IQR 7.7). The median follow-up duration was 21.8&nbsp;years (IQR 23.3). Recurrent oral (100%) and genital ulcers (67.6%) and pseudofolliculitis (56.8%) were the most common symptoms associated with MSM. At disease onset, 31 subjects had arthritis (83.8%), 33 arthralgia (89.2%), and 14 myalgia (37.8%). Arthritis was monoarticular in 9/31 cases (29%), oligoarticular in 10 (32.3%), polyarticular in 5 (16.1%), axial in 7 (22.6%). Over time, arthritis became chronic-recurrent in 67.7% of cases and 7/31 patients had joint erosions (22.6%). The median Behçet's Syndrome Overall Damage Index was 0 (range 0-4). Colchicine was inefficacious for MSM in 4/14 cases (28.6%), independently from the type of MSM (p = 0.46) or the concomitant therapy (p = 0.30 for cDMARDs, p = 1.00 for glucocorticoids); cDMARDs and bDMARDs were inefficacious for MSM in 6/19 (31.4%) and 5/12 (41.7%) cases. The presence of myalgia was associated with bDMARDs inefficacy (p = 0.014). To conclude,&nbsp;MSM in children with BS are frequently associated with recurrent ulcers and pseudofolliculitis. Arthritis is mostly mono- or oligoarticular, but sacroiliitis is not unusual. Prognosis of this subset of BS is overall favorable, though the presence of myalgia negatively affects response to biologic therapies. ClinicalTrials.gov Identifier: NCT05200715 (registered on December 18, 2021)

    Microelectronics-Based Biosensors Dedicated to the Detection of Neurotransmitters: A Review

    Get PDF
    Dysregulation of neurotransmitters (NTs) in the human body are related to diseases such as Parkinson's and Alzheimer's. The mechanisms of several neurological disorders, such as epilepsy, have been linked to NTs. Because the number of diagnosed cases is increasing, the diagnosis and treatment of such diseases are important. To detect biomolecules including NTs, microtechnology, micro and nanoelectronics have become popular in the form of the miniaturization of medical and clinical devices. They offer high-performance features in terms of sensitivity, as well as low-background noise. In this paper, we review various devices and circuit techniques used for monitoring NTs in vitro and in vivo and compare various methods described in recent publications
    corecore