137 research outputs found

    Fils RSS

    Get PDF
    Intervention à la 6e journée FORMIST qui s\u27est déroulée le 15 juin 2006 à l\u27ENSSIB. Ce document présente les grandes caractéristiques des fils RSS et des outils d\u27exploitation de ces fils, et donne des points de départ bibliographiques et des ressources sur ce sujet

    Après les inaugurations, quel avenir pour les missions régionales des BMVR ?

    Get PDF

    Bench testing of a new hyperbaric chamber ventilator at different atmospheric pressures

    Get PDF
    Purpose: Providing mechanical ventilation is challenging at supra-atmospheric pressure. The higher gas density increases resistance, reducing the flow delivered by the ventilator. A new hyperbaric ventilator (Siaretron IPER 1000) is said to compensate for these effects automatically. The aim of this bench test study was to validate the compensation, define its limits and provide details on the ventilator's output at varied atmospheric pressures. Methods: Experiments were conducted inside a multiplace hyperbaric chamber at 1, 2.2, 2.8 and 4 atmospheres absolute (ATA), with the ventilator connected to a test lung. Transducers were recalibrated at each ATA level. Various ventilator settings were tested in volume and pressure control modes. Measured tidal volumes were compared with theoretical predictions based on gas laws. Results: Results confirmed the ventilator's ability to provide compensation, but also identified its limits. The compensation range could be predicted and depended on the maximal flow attainable, decreasing linearly with increasing atmospheric pressure. With settings inside the range, tidal volumes approximated set values (mean error 10±5%). With settings outside the range, the volume was limited to the predicted maximal value calculated from maximal flow. A practical guide for clinicians is provided. Conclusion: The IPER 1000 ventilator attempted to deliver stable tidal volume by adjusting the opening of the inspiratory valve in proportion to atmospheric pressure. Adequate compensation was observed, albeit only within a predictable range, which can be reliably predicted for each setting and ATA level combination. Setting a tidal volume outside this range can result in an unwanted decrease in minute ventilatio

    Utilisation des fils RSS en bibliothèque

    Get PDF

    Accuracy and precision of end-expiratory lung-volume measurements by automated nitrogen washout/washin technique in patients with acute respiratory distress syndrome

    Get PDF
    Introduction End-expiratory lung volume (EELV) is decreased in acute respiratory distress syndrome (ARDS), and bedside EELV measurement may help to set positive end-expiratory pressure (PEEP). Nitrogen washout/washin for EELV measurement is available at the bedside, but assessments of accuracy and precision in real-life conditions are scant. Our purpose was to (a) assess EELV measurement precision in ARDS patients at two PEEP levels (three pairs of measurements), and (b) compare the changes (Δ) induced by PEEP for total EELV with the PEEP-induced changes in lung volume above functional residual capacity measured with passive spirometry (ΔPEEP-volume). The minimal predicted increase in lung volume was calculated from compliance at low PEEP and ΔPEEP to ensure the validity of lung-volume changes. Methods Thirty-four patients with ARDS were prospectively included in five university-hospital intensive care units. ΔEELV and ΔPEEP volumes were compared between 6 and 15 cm H2O of PEEP. Results After exclusion of three patients, variability of the nitrogen technique was less than 4%, and the largest difference between measurements was 81 ± 64 ml. ΔEELV and ΔPEEP-volume were only weakly correlated (r 2 = 0.47); 95% confidence interval limits, -414 to 608 ml). In four patients with the highest PEEP (≥ 16 cm H2O), ΔEELV was lower than the minimal predicted increase in lung volume, suggesting flawed measurements, possibly due to leaks. Excluding those from the analysis markedly strengthened the correlation between ΔEELV and ΔPEEP volume (r 2 = 0.80). Conclusions In most patients, the EELV technique has good reproducibility and accuracy, even at high PEEP. At high pressures, its accuracy may be limited in case of leaks. The minimal predicted increase in lung volume may help to check for accuracy

    Quantification of short and long asbestos fibers to assess asbestos exposure: a review of fiber size toxicity.

    Get PDF
    International audienceThe fibrogenicity and carcinogenicity of asbestos fibers are dependent on several fiber parameters including fiber dimensions. Based on the WHO (World Health Organization) definition, the current regulations focalise on long asbestos fibers (LAF) (Length: L ≥ 5 μm, Diameter: D  3). However air samples contain short asbestos fibers (SAF) (L < 5 μm). In a recent study we found that several air samples collected in buildings with asbestos containing materials (ACM) were composed only of SAF, sometimes in a concentration of ≥10 fibers.L-1. This exhaustive review focuses on available information from peer-review publications on the size-dependent pathogenetic effects of asbestos fibers reported in experimental in vivo and in vitro studies. In the literature, the findings that SAF are less pathogenic than LAF are based on experiments where a cut-off of 5 μm was generally made to differentiate short from long asbestos fibers. Nevertheless, the value of 5 μm as the limit for length is not based on scientific evidence, but is a limit for comparative analyses. From this review, it is clear that the pathogenicity of SAF cannot be completely ruled out, especially in high exposure situations. Therefore, the presence of SAF in air samples appears as an indicator of the degradation of ACM and inclusion of their systematic search should be considered in the regulation. Measurement of these fibers in air samples will then make it possible to identify pollution and anticipate health risk

    Information conveyed by electrical diaphragmatic activity during unstressed, stressed and assisted spontaneous breathing: a physiological study.

    Get PDF
    The electrical activity of the crural diaphragm (Eadi), a surrogate of respiratory drive, can now be measured at the bedside in mechanically ventilated patients with a specific catheter. The expected range of Eadi values under stressed or assisted spontaneous breathing is unknown. This study explored Eadi values in healthy subjects during unstressed (baseline), stressed (with a resistance) and assisted spontaneous breathing. The relation between Eadi and inspiratory effort was analyzed. Thirteen healthy male volunteers were included in this randomized crossover study. Eadi and esophageal pressure (Peso) were recorded during unstressed and stressed spontaneous breathing and under assisted ventilation delivered in pressure support (PS) at low and high assist levels and in neurally adjusted ventilatory assist (NAVA). Overall eight different situations were assessed in each participant (randomized order). Peak, mean and integral of Eadi, breathing pattern, esophageal pressure-time product (PTPeso) and work of breathing (WOB) were calculated offline. Median [interquartile range] peak Eadi at baseline was 17 [13-22] μV and was above 10 μV in 92% of the cases. Eadi &lt;sub&gt;max&lt;/sub&gt; defined as Eadi measured at maximal inspiratory capacity reached 90 [63 to 99] μV. Median peak Eadi/Eadi &lt;sub&gt;max&lt;/sub&gt; ratio was 16.8 [15.6-27.9]%. Compared to baseline, respiratory rate and minute ventilation were decreased during stressed non-assisted breathing, whereas peak Eadi and PTPeso were increased. During unstressed assisted breathing, peak Eadi decreased during high-level PS compared to unstressed non-assisted breathing and to NAVA (p = 0.047). During stressed breathing, peak Eadi was lower during all assisted ventilation modalities compared to stressed non-assisted breathing. During assisted ventilation, across the different conditions, peak Eadi changed significantly, whereas PTPeso and WOB/min were not significantly modified. Finally, Eadi signal was still present even when Peso signal was suppressed due to high assist levels. Eadi analysis provides complementary information compared to respiratory pattern and to Peso monitoring, particularly in the presence of high assist levels. Trial registration The study was registered as NCT01818219 in clinicaltrial.gov. Registered 28 February 2013

    6es Rencontres FORMIST - 2006

    Get PDF
    Actes des 6èmes rencontres FORMIST qui se sont déroulées le 15 juin 2006 à l\u27ENSSIB. Tour d\u27horizon des usages des nouvelles technologies de l\u27information par les étudiants : pratiques documentaires, outils bibliographiques, aides et formation à la recherche d\u27information, réseaux sociaux. Synthèses sur des outils particuliers : cartes heuristiques, wikis, flux RSS, blogs, etc

    Interstitial Lung Abnormalities Detected by CT in Asbestos-Exposed Subjects Are More Likely Associated to Age

    Get PDF
    OBJECTIVE: the aim of this study was to evaluate the association between interstitial lung abnormalities, asbestos exposure and age in a population of retired workers previously occupationally exposed to asbestos. METHODS: previously occupationally exposed former workers to asbestos eligible for a survey conducted between 2003 and 2005 in four regions of France, underwent chest CT examinations and pulmonary function testing. Industrial hygienists evaluated asbestos exposure and calculated for each subject a cumulative exposure index (CEI) to asbestos. Smoking status information was also collected in this second round of screening. Expert radiologists performed blinded independent double reading of chest CT-scans and classified interstitial lung abnormalities into: no abnormality, minor interstitial findings, interstitial findings inconsistent with UIP, possible or definite UIP. In addition, emphysema was assessed visually (none, minor: emphysema 50% of the lung). Logistic regression models adjusted for age and smoking were used to assess the relationship between interstitial lung abnormalities and occupational asbestos exposure. RESULTS: the study population consisted of 2157 male subjects. Interstitial lung abnormalities were present in 365 (16.7%) and emphysema in 444 (20.4%). Significant positive association was found between definite or possible UIP pattern and age (OR adjusted =1.08 (95% CI: 1.02-1.13)). No association was found between interstitial abnormalities and CEI or the level of asbestos exposure. CONCLUSION: presence of interstitial abnormalities at HRCT was associated to aging but not to cumulative exposure index in this cohort of former workers previously occupationally exposed to asbestos

    Deep Learning for the Automatic Quantification of Pleural Plaques in Asbestos-Exposed Subjects

    Get PDF
    OBJECTIVE: This study aimed to develop and validate an automated artificial intelligence (AI)-driven quantification of pleural plaques in a population of retired workers previously occupationally exposed to asbestos. METHODS: CT scans of former workers previously occupationally exposed to asbestos who participated in the multicenter APEXS (Asbestos PostExposure Survey) study were collected retrospectively between 2010 and 2017 during the second and the third rounds of the survey. A hundred and forty-one participants with pleural plaques identified by expert radiologists at the 2nd and the 3rd CT screenings were included. Maximum Intensity Projection (MIP) with 5 mm thickness was used to reduce the number of CT slices for manual delineation. A Deep Learning AI algorithm using 2D-convolutional neural networks was trained with 8280 images from 138 CT scans of 69 participants for the semantic labeling of Pleural Plaques (PP). In all, 2160 CT images from 36 CT scans of 18 participants were used for AI testing versus ground-truth labels (GT). The clinical validity of the method was evaluated longitudinally in 54 participants with pleural plaques. RESULTS: The concordance correlation coefficient (CCC) between AI-driven and GT was almost perfect (>0.98) for the volume extent of both PP and calcified PP. The 2D pixel similarity overlap of AI versus GT was good (DICE = 0.63) for PP, whether they were calcified or not, and very good (DICE = 0.82) for calcified PP. A longitudinal comparison of the volumetric extent of PP showed a significant increase in PP volumes (p < 0.001) between the 2nd and the 3rd CT screenings with an average delay of 5 years. CONCLUSIONS: AI allows a fully automated volumetric quantification of pleural plaques showing volumetric progression of PP over a five-year period. The reproducible PP volume evaluation may enable further investigations for the comprehension of the unclear relationships between pleural plaques and both respiratory function and occurrence of thoracic malignancy
    corecore