192 research outputs found
Recommended from our members
Framework for Detection and Localization of Coronary Non-Calcified Plaques in Cardiac CTA using Mean Radial Profiles
Background and Objective: The high mortality rate associated with coronary heart disease (CHD) has driven intensive research in cardiac imaging and image analysis. The advent of computed tomography angiography (CTA) has turned non-invasive diagnosis of cardiovascular anomalies into reality as calcified coronary plaques can be easily identified due to their high intensity values. However, the detection of non-calcified plaques in CTA is still a challenging problem because of lower intensity values, which are often similar to the nearby blood and muscle tissues. In this work, we propose the use of mean radial profiles for the detection of non-calcified plaques in CTA imagery.
Methods: Accordingly, we computed radial profiles by averaging the image intensity in concentric rings around the vessel centreline in a first stage. In the subsequent stage, an SVM classifier is applied to identify the abnormal coronary segments. For occluded segments, we further propose a derivative-based method to localize the position and length of the plaque inside the segment.
Results: A total of 32 CTA volumes were analysed and a detection accuracy of 88.4% with respect to the manual expert was achieved. The plaque localization accuracy was computed using the Dice similarity coefficient and a mean of 83.2% was achieved.
Conclusion: The consistent performance for multi-vendor, multi-institution data demonstrates the reproducibility of our method across different CTA datasets with a good agreement with manual expert annotations
Multislice CT angiography in cardiac imaging: prospective ECG-gating or retrospective ECG-gating?
With the advent of multislice CT more than a decade ago, multislice CT angiography has demonstrated a huge potential in the less invasive imaging of cardiovascular disease, especially in the diagnosis of coronary artery disease. The diagnostic accuracy of multislice CT angiography has been significantly augmented with the rapid technical developments ranging from the initial 4-slice, to the current 64-slice and 256 and 320-slice CT scanners. This is mainly demonstrated by the improved spatial and temporal resolution when compared to the earlier type of CT scanners. Traditionally, multislice CT angiography is acquired with retrospective ECG-gating with acquisition of volume data at the expense of increased radiation dose, since data is acquired at the entire cardiac cycle, although not all of them are used for postprocessing or reconstructions. Recently, there is an increasing trend of utilising prospective ECG-gating in cardiac imaging with latest multislice CT scanners (64 or more slices) with significant reduction of radiation dose when compared to retrospective ECG-gating method. However, there is some debate as to the diagnostic value of prospective ECG-gating in the diagnosis of coronary artery disease, despite its attractive ability to reduce radiation dose. This article will review the performance of retrospective ECG-gating in the diagnostic value of coronary artery disease, highlight the potential applications of prospective ECG-gating, and explore the future directions of multislice CT angiography in cardiac imaging
Recommended from our members
Framework for Detection and Localization of Coronary Non-Calcified Plaques in Cardiac CTA using Mean Radial Profiles
Background and Objective: The high mortality rate associated with coronary heart disease (CHD) has driven intensive research in cardiac imaging and image analysis. The advent of computed tomography angiography (CTA) has turned non-invasive diagnosis of cardiovascular anomalies into reality as calcified coronary plaques can be easily identified due to their high intensity values. However, the detection of non-calcified plaques in CTA is still a challenging problem because of lower intensity values, which are often similar to the nearby blood and muscle tissues. In this work, we propose the use of mean radial profiles for the detection of non-calcified plaques in CTA imagery.
Methods: Accordingly, we computed radial profiles by averaging the image intensity in concentric rings around the vessel centreline in a first stage. In the subsequent stage, an SVM classifier is applied to identify the abnormal coronary segments. For occluded segments, we further propose a derivative-based method to localize the position and length of the plaque inside the segment.
Results: A total of 32 CTA volumes were analysed and a detection accuracy of 88.4% with respect to the manual expert was achieved. The plaque localization accuracy was computed using the Dice similarity coefficient and a mean of 83.2% was achieved.
Conclusion: The consistent performance for multi-vendor, multi-institution data demonstrates the reproducibility of our method across different CTA datasets with a good agreement with manual expert annotations
Evaluation of Reperfused Myocardial Infarction by Low-Dose Multidetector Computed Tomography Using Prospective Electrocardiography (ECG)-Triggering: Comparison with Magnetic Resonance Imaging
PURPOSE: To evaluate the potential of prospective electrocardiography (ECG)- gated 64-slice multidetector computed tomography (MDCT) for evaluation of myocardial enhancement, infarct size, and stent patency after percutaneous coronary intervention (PCI) with stenting in patients with myocardial infarction.
MATERIALS AND METHODS: Seventeen patients who were admitted with acute myocardial infarction were examined with prospective ECG-gated 64-slice cardiac MDCT and magnetic resonance (MR) imaging after reperfusion using PCI with stenting. Cardiac MDCT was performed with two different phases: arterial and delayed phases. We evaluated the stent patency on the arterial phase, and nonviable myocardium on the delayed phase of computed tomography (CT) image, and they were compared with the results from the delayed MR images.
RESULTS: Total mean radiation dose was 7.7 +/- 0.5 mSv on the two phases of CT images. All patients except one showed good patency of the stent at the culprit lesion on the arterial phase CT images. All patients had hyperenhanced area on the delayed phase CT images, which correlated well with those on the delayed phase MR images, with a mean difference of 1.6% (20 +/- 10% vs. 22 +/- 10%, r = 0.935, p = 0.10). Delayed MR images had a better contrast-to-noise ratio (CNR) than delayed CT images (27.1 +/- 17.8% vs. 4.3 +/- 2.1%, p < 0.001).
CONCLUSION: Prospective ECG-gated 64-slice MDCT provides the potential to evaluate myocardial viability on delayed phase as well as for stent patency on arterial phase with an acceptable radiation dose after PCI with stenting in patients with myocardial infarctionope
Comparison of (semi-)automatic and manually adjusted measurements of left ventricular function in dual source computed tomography using three different software tools
To assess the accuracy of (semi-)automatic measurements of left ventricular (LV) functional parameters in cardiac dual-source computed tomography (DSCT) compared to manually adjusted measurements in three different workstations. Forty patients, who underwent cardiac DSCT, were included (31 men, mean age 58 ± 14 years). Multiphase reconstructions were made with ten series at every 10% of the RR-interval. LV function analysis was performed on three different, commercially available workstations. On all three workstations, end-systolic volume (ESV), end-diastolic volume (EDV), LV ejection fraction (LVEF) and myocardial mass (MM) were calculated as automatically as possible. With the same DSCT datasets, LV functional parameters were also calculated with as many manual adjustments as needed for accurate assessment for all three software tools. For both semi-automatic as well as manual methods, time needed for evaluation was recorded. Paired t-tests were employed to calculate differences in LV functional parameters. Repeated measurements were performed to determine intra-observer and inter-observer variability. (Semi-)automatic measurements revealed a good correlation with manually adjusted measurements for Vitrea (LVEF r = 0.93, EDV r = 0.94, ESV r = 0.98 and MM r = 0.94) and Aquarius (LVEF r = 0.96, EDV r = 0.94, ESV r = 0.98 and MM r = 0.96). Also, good correlation was obtained for Circulation, except for LVEF (LVEF r = 0.45, EDV r = 0.93, ESV r = 0.92 and MM r = 0.86). However, statistically significant differences were found between (semi-)automatically and manually adjusted measurements for LVEF (P < 0.05) and ESV (P < 0.001) in Vitrea, all LV functional parameters in Circulation (P < 0.001) and EDV, ESV and MM (<0.001) in Aquarius Workstation. (Semi-)automatic measurement of LV functional parameters is feasible, but significant differences were found for at least two different functional parameters in all three workstations. Therefore, expert manual correction is recommended at all times
Optimal phase for coronary interpretations and correlation of ejection fraction using late-diastole and end-diastole imaging in cardiac computed tomography angiography: implications for prospective triggering
A typical acquisition protocol for multi-row detector computed tomography (MDCT) angiography is to obtain all phases of the cardiac cycle, allowing calculation of ejection fraction (EF) simultaneously with plaque burden. New MDCT protocols scanner, designed to reduce radiation, use prospectively acquired ECG gated image acquisition to obtain images at certain specific phases of the cardiac cycle with least coronary artery motion. These protocols do not we allow acquisition of functional data which involves measurement of ejection fraction requiring end-systolic and end-diastolic phases. We aimed to quantitatively identify the cardiac cycle phase that produced the optimal images as well as aimed to evaluate, if obtaining only 35% (end-systole) and 75% (as a surrogate for end-diastole) would be similar to obtaining the full cardiac cycle and calculating end diastolic volumes (EDV) and EF from the 35th and 95th percentile images. 1,085 patients with no history of coronary artery disease were included; 10 images separated by 10% of R–R interval were retrospectively constructed. Images with motion in the mid portion of RCA were graded from 1 to 3; with ‘1’ being no motion, ‘2’ if 0 to <1 mm motion, and ‘3’ if there is >1 mm motion and/or non-interpretable study. In a subgroup of 216 patients with EF > 50%, we measured left ventricular (LV) volumes in the 10 phases, and used those obtained during 25, 35, 75 and 95% phase to calculate the EF for each patient. The average heart rate (HR) for our patient group was 56.5 ± 8.4 (range 33–140). The distribution of image quality at all heart rates was 958 (88.3%) in Grade 1, 113 (10.42%) in Grade 2 and 14 (1.29%) in Grade 3 images. The area under the curve for optimum image quality (Grade 1 or 2) in patients with HR > 60 bpm for phase 75% was 0.77 ± 0.04 [95% CI: 0.61–0.87], while for similar heart rates the area under the curve for phases 75 + 65 + 55 + 45% combined was 0.92 ± 0.02. LV volume at 75% phase was strongly correlated with EDV (LV volume at 95% phase) (r = 0.970, P < 0.001). There was also a strong correlation between LVEF (75_35) and LVEF (95_35) (r = 0.93, P < 0.001). Subsequently, we developed a formula to correct for the decrement in LVEF using 35–75% phase: LVEF (95_35) = 0.783 × LVEF (75_35) + 20.68; adjusted R2 = 0.874, P < 0.001. Using 64 MDCT scanners, in order to acquire >90% interpretable studies, if HR < 60 bpm 75% phase of RR interval provides optimal images; while for HR > 60 analysis of images in 4 phases (75, 35, 45 and 55%) is needed. Our data demonstrates that LVEF can be predicted with reasonable accuracy by using data acquired in phases 35 and 75% of the R–R interval. Future prospective acquisition that obtains two phases (35 and 75%) will allow for motion free images of the coronary arteries and EF estimates in over 90% of patients
Functional assessment of coronary artery flow using adenosine stress dual-energy CT: a preliminary study
We attempted to assess coronary artery flow using adenosine-stress and dual-energy mode with dual-source CT (DE-CT). Data of 18 patients with suspected coronary arteries disease who had undergone cardiac DE-CT were retrospectively analyzed. The patients were divided into two groups: 10 patients who performed adenosine stress CT, and 8 patients who performed rest CT as controls. We reconstructed an iodine map and composite images at 120 kV (120 kV images) using raw data with scan parameters of 100 and 140 kV. We measured mean attenuation in the coronary artery proximal to the distal portion on both the iodine map and 120 kV images. Coronary enhancement ratio (CER) was calculated by dividing mean attenuation in the coronary artery by attenuation in the aortic root, and was used as an estimate of coronary enhancement. Coronary stenosis was identified as a reduction in diameter of >50% on CT angiogram, and myocardial ischemia was diagnosed by adenosine-stress myocardial perfusion scintigraphy. The iodine map showed that CER was significantly lower for ischemic territories (0.76 ± 0.06) or stenosed coronary arteries (0.77 ± 0.06) than for non-ischemic territories (0.95 ± 0.21, P = 0.02) or non-stenosed coronary arteries (1.07 ± 0.33, P < 0.001). The 120 kV images showed no difference in CER between these two groups. Use of CER on the iodine map separated ischemic territories from non-ischemic territories with a sensitivity of 86% and a specificity of 75%. Our quantification is the first non-invasive analytical technique for assessment of coronary artery flow using cardiac CT. CER on the iodine map is a candidate method for demonstration of alteration in coronary artery flow under adenosine stress, which is related to the physiological significance of coronary artery disease
- …