314 research outputs found

    Tracking Energy Flow Using a Volumetric Acoustic Intensity Imager (VAIM)

    Get PDF
    A new measurement device has been invented at the Naval Research Laboratory which images instantaneously the intensity vector throughout a three-dimensional volume nearly a meter on a side. The measurement device consists of a nearly transparent spherical array of 50 inexpensive microphones optimally positioned on an imaginary spherical surface of radius 0.2m. Front-end signal processing uses coherence analysis to produce multiple, phase-coherent holograms in the frequency domain each related to references located on suspect sound sources in an aircraft cabin. The analysis uses either SVD or Cholesky decomposition methods using ensemble averages of the cross-spectral density with the fixed references. The holograms are mathematically processed using spherical NAH (nearfield acoustical holography) to convert the measured pressure field into a vector intensity field in the volume of maximum radius 0.4 m centered on the sphere origin. The utility of this probe is evaluated in a detailed analysis of a recent in-flight experiment in cooperation with Boeing and NASA on NASA s Aries 757 aircraft. In this experiment the trim panels and insulation were removed over a section of the aircraft and the bare panels and windows were instrumented with accelerometers to use as references for the VAIM. Results show excellent success at locating and identifying the sources of interior noise in-flight in the frequency range of 0 to 1400 Hz. This work was supported by NASA and the Office of Naval Research

    Reconstruction of the Acoustic Field Using a Conformal Array

    Get PDF
    Near-field acoustical holography (NAH) requires the measurement of the near-field pressure field over a conformal and closed surface in order to recover the acoustic field on a nearby surface. We are interested in the reconstruction of the acoustic field over the fuselage of a Boeing 757 airplane when pressure data is available over an array of microphones that are conformal to the fuselage surface. In this case the strict NAH theory does not hold, but still there are techniques used to overcome this difficulty. The best known is patch NAH, which has been used for planar surfaces. In this work we will discuss two new techniques used for surfaces with an arbitrarily shape: patch inverse boundary element methods (IBEM) and patch equivalent sources method (ESM). We will discuss the theoretical justification of the method and show reconstructions for in-flight data taken inside a Boeing 757 airplane

    Influenza Vaccination Coverage among Adults with Asthma: Findings from the 2000 Behavioral Risk Factor Surveillance System

    Get PDF
    The prevalence of asthma has increased substantially in the United States since 1980 (1). The primary clinical and public health strategy to reduce the burden of asthma is to prevent exacerbation of the disease, of which upper and lower respiratory tract infections are a major cause (2–5). One such infection—influenza— and its complications are potentially preventable with annual vaccination, which is a safe and effective method (6,7), including among persons with asthma (8). Because persons with asthma are at increased risk of complications from influenza, they are advised to receive annual influenza vaccinations (9), unless there are contraindications. Little is known about how adults with asthma or health care providers comply with the annual influenza vaccination recommendations issued by the Advisory Committee on Immunization Practices (9). Among children with asthma, however, vaccination levels are low (10 –15). We therefore sought to assess the influenza vaccination coverage among adults with asthma, as well as to identify predictors of receiving such a vaccination

    Acoustic Source Localization in Aircraft Interiors Using Microphone Array Technologies

    Get PDF
    Using three microphone array configurations at two aircraft body stations on a Boeing 777-300ER flight test, the acoustic radiation characteristics of the sidewall and outboard floor system are investigated by experimental measurement. Analysis of the experimental data is performed using sound intensity calculations for closely spaced microphones, PATCH Inverse Boundary Element Nearfield Acoustic Holography, and Spherical Nearfield Acoustic Holography. Each method is compared assessing strengths and weaknesses, evaluating source identification capability for both broadband and narrowband sources, evaluating sources during transient and steady-state conditions, and quantifying field reconstruction continuity using multiple array positions

    The silence of self-knowledge

    Get PDF
    Gareth Evans famously affirmed an explanatory connection between answering the question whether p and knowing whether one believes that p. This is commonly interpreted in terms of the idea that judging that p constitutes an adequate basis for the belief that one believes that p. This paper formulates and defends an alternative, more modest interpretation, which develops from the suggestion that one can know that one believes that p in judging that p

    Comparison of Different Measurement Technologies for the In-Flight Assessment of Radiated Acoustic Intensity

    Get PDF
    A series of tests was planned and conducted in the Interior Noise Test Facility at Boeing Field, on the NASA Aries 757 flight research aircraft, and in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center. These tests were designed to answer several questions concerning the use of array methods in flight. One focus of the tests was determining whether and to what extent array methods could be used to identify the effects of an acoustical treatment applied to a limited portion of an aircraft fuselage. Another focus of the tests was to verify that the arrays could be used to localize and quantify a known source purposely placed in front of the arrays. Thus the issues related to backside sources and flanking paths present in the complicated sound field were addressed during these tests. These issues were addressed through the use of reference transducers, both accelerometers mounted to the fuselage and microphones in the cabin, that were used to correlate the pressure holograms. measured by the microphone arrays using either SVD methods or partial coherence methods. This correlation analysis accepts only energy that is coherent with the sources sensed by the reference transducers, allowing a noise control engineer to only identify and study those vibratory sources of interest. The remainder of this paper will present a detailed description of the test setups that were used in this test sequence and typical results of the NAH/IBEM analysis used to reconstruct the sound fields. Also, a comparison of data obtained in the laboratory environments and during flights of the 757 aircraft will be made

    Appropriate disclosure of a diagnosis of dementia : identifying the key behaviours of 'best practice'

    Get PDF
    Background: Despite growing evidence that many people with dementia want to know their diagnosis, there is wide variation in attitudes of professionals towards disclosure. The disclosure of the diagnosis of dementia is increasingly recognised as being a process rather than a one-off behaviour. However, the different behaviours that contribute to this process have not been comprehensively defined. No intervention studies to improve diagnostic disclosure in dementia have been reported to date. As part of a larger study to develop an intervention to promote appropriate disclosure, we sought to identify important disclosure behaviours and explore whether supplementing a literature review with other methods would result in the identification of new behaviours. Methods: To identify a comprehensive list of behaviours in disclosure we conducted a literature review, interviewed people with dementia and informal carers, and used a consensus process involving health and social care professionals. Content analysis of the full list of behaviours was carried out. Results: Interviews were conducted with four people with dementia and six informal carers. Eight health and social care professionals took part in the consensus panel. From the interviews, consensus panel and literature review 220 behaviours were elicited, with 109 behaviours over-lapping. The interviews and consensus panel elicited 27 behaviours supplementary to the review. Those from the interviews appeared to be self-evident but highlighted deficiencies in current practice and from the panel focused largely on balancing the needs of people with dementia and family members. Behaviours were grouped into eight categories: preparing for disclosure; integrating family members; exploring the patient's perspective; disclosing the diagnosis; responding to patient reactions; focusing on quality of life and well-being; planning for the future; and communicating effectively. Conclusion: This exercise has highlighted the complexity of the process of disclosing a diagnosis of dementia in an appropriate manner. It confirms that many of the behaviours identified in the literature (often based on professional opinion rather than empirical evidence) also resonate with people with dementia and informal carers. The presence of contradictory behaviours emphasises the need to tailor the process of disclosure to individual patients and carers. Our combined methods may be relevant to other efforts to identify and define complex clinical practices for further study.This project is funded by UK Medical Research Council, Grant reference number G0300999

    Characterization of space dust using acoustic impact detection

    Get PDF
    This paper describes studies leading to the development of an acoustic instrument for measuring properties of micrometeoroids and other dust particles in space. The instrument uses a pair of easily penetrated membranes separated by a known distance. Sensors located on these films detect the transient acoustic signals produced by particle impacts. The arrival times of these signals at the sensor locations are used in a simple multilateration calculation to measure the impact coordinates on each film. Particle direction and speed are found using these impact coordinates and the known membrane separations. This ability to determine particle speed, direction, and time of impact provides the information needed to assign the particle’s orbit and identify its likely origin. In many cases additional particle properties can be estimated from the signal amplitudes, including approximate diameter and (for small particles) some indication of composition/morphology. Two versions of this instrument were evaluated in this study. Fiber optic displacement sensors are found advantageous when very thin membranes can be maintained in tension (solar sails, lunar surface). Piezoelectric strain sensors are preferred for thicker films without tension (long duration free flyers). The latter was selected for an upcoming installation on the International Space Station

    Persistent risk of subsequent procedures and mortality in patients after interrupted aortic arch repair: A Congenital Heart Surgeons' Society study

    Get PDF
    ObjectiveMultiple subsequent procedures directed at the arch and/or the left ventricular outflow tract are frequently required after interrupted aortic arch repair. We the investigated patterns and factors associated with these subsequent procedures and mortality.MethodsWe reviewed the data from 447 patients with interrupted aortic arch at 33 institutions enrolled from 1987 to 1997. We classified the subsequent procedures by type (catheter-based or surgical) and focus (arch, left ventricular outflow tract, and “other” cardiovascular lesions). We used competing risks and modulated renewal analysis to explore subsequent procedures.ResultsThere were 158 subsequent arch and 100 left ventricular outflow tract procedures. Freedom from death at 21 years was 60% overall. The risk of additional subsequent arch procedures decreased after the first subsequent arch procedure in the acute phase, but did not significantly change in the chronic phase. The risk of additional subsequent left ventricular outflow tract procedures increased after the first subsequent left ventricular outflow tract procedure in the chronic phase. The risk factors for subsequent arch procedures and mortality, but not for subsequent outflow track procedures, were related in a complex way to previous procedures and their timing.ConclusionsInterrupted aortic arch is a chronic disease in which patients often undergo multiple subsequent procedures with persistent risk for additional intervention and mortality. The risk factors are related to the nature and timing of previous procedures and to the morphology and details of the index procedure. Interrupted aortic arch should be considered a chronic disorder

    Applying refinement to the use of mice and rats in rheumatoid arthritis research

    Get PDF
    Rheumatoid arthritis (RA) is a painful, chronic disorder and there is currently an unmet need for effective therapies that will benefit a wide range of patients. The research and development process for therapies and treatments currently involves in vivo studies, which have the potential to cause discomfort, pain or distress. This Working Group report focuses on identifying causes of suffering within commonly used mouse and rat ‘models’ of RA, describing practical refinements to help reduce suffering and improve welfare without compromising the scientific objectives. The report also discusses other, relevant topics including identifying and minimising sources of variation within in vivo RA studies, the potential to provide pain relief including analgesia, welfare assessment, humane endpoints, reporting standards and the potential to replace animals in RA research
    corecore