513 research outputs found

    Virtual depth by active background suppression: Revisiting the cosmic muon induced background of GERDA Phase II

    Full text link
    In-situ production of long-lived isotopes by cosmic muon interactions may generate a non-negligible background for deep underground rare event searches. Previous Monte Carlo studies for the GERDA experiment at LNGS identified the delayed decays of 77^{77}Ge and its metastable state 77m^{77m}Ge as dominant cosmogenic background in the search for neutrinoless double beta decay of 76^{76}Ge. This might limit the sensitivity of next generation experiments aiming for increased 76^{76}Ge mass at background-free conditions and thereby define a minimum depth requirement. A re-evaluation of the 77(m)^{77(m)}Ge background for the GERDA experiment has been carried out by a set of Monte Carlo simulations. The obtained 77(m)^{77(m)}Ge production rate is (0.21±\pm0.01) nuclei/(kg⋅\cdotyr). After application of state-of-the-art active background suppression techniques and simple delayed coincidence cuts this corresponds to a background contribution of (2.7±\pm0.3)⋅10−6\cdot10^{-6} cts/(keV⋅\cdotkg⋅\cdotyr). The suppression achieved by this strategy equals an effective muon flux reduction of more than one order of magnitude. This virtual depth increase opens the way for next generation rare event searches.Comment: 9 pages, 5 figure

    A hydrogen beam to characterize the ASACUSA antihydrogen hyperfine spectrometer

    Full text link
    The antihydrogen programme of the ASACUSA collaboration at the antiproton decelerator of CERN focuses on Rabi-type measurements of the ground-state hyperfine splitting of antihydrogen for a test of the combined Charge-Parity-Time symmetry. The spectroscopy apparatus consists of a microwave cavity to drive hyperfine transitions and a superconducting sextupole magnet for quantum state analysis via Stern-Gerlach separation. However, the small production rates of antihydrogen forestall comprehensive performance studies on the spectroscopy apparatus. For this purpose a hydrogen source and detector have been developed which in conjunction with ASACUSA's hyperfine spectroscopy equipment form a complete Rabi experiment. We report on the formation of a cooled, polarized, and time modulated beam of atomic hydrogen and its detection using a quadrupole mass spectrometer and a lock-in amplification scheme. In addition key features of ASACUSA's hyperfine spectroscopy apparatus are discussed.

    Evaluating a radiotherapy deep learning synthetic CT algorithm for PET-MR attenuation correction in the pelvis

    Get PDF
    \ua9 2024, The Author(s). Background: Positron emission tomography–magnetic resonance (PET-MR) attenuation correction is challenging because the MR signal does not represent tissue density and conventional MR sequences cannot image bone. A novel zero echo time (ZTE) MR sequence has been previously developed which generates signal from cortical bone with images acquired in 65 s. This has been combined with a deep learning model to generate a synthetic computed tomography (sCT) for MR-only radiotherapy. This study aimed to evaluate this algorithm for PET-MR attenuation correction in the pelvis. Methods: Ten patients being treated with ano-rectal radiotherapy received a 18 F-FDG-PET-MR in the radiotherapy position. Attenuation maps were generated from ZTE-based sCT (sCTAC) and the standard vendor-supplied MRAC. The radiotherapy planning CT scan was rigidly registered and cropped to generate a gold standard attenuation map (CTAC). PET images were reconstructed using each attenuation map and compared for standard uptake value (SUV) measurement, automatic thresholded gross tumour volume (GTV) delineation and GTV metabolic parameter measurement. The last was assessed for clinical equivalence to CTAC using two one-sided paired t tests with a significance level corrected for multiple testing of p≤ 0.05 / 7 = 0.007 . Equivalence margins of \ub1 3.5 % were used. Results: Mean whole-image SUV differences were −0.02% (sCTAC) compared to −3.0% (MRAC), with larger differences in the bone regions (−0.5% to −16.3%). There was no difference in thresholded GTVs, with Dice similarity coefficients ≥ 0.987 . However, there were larger differences in GTV metabolic parameters. Mean differences to CTAC in SUV max were 1.0 \ub1 0.8 % (\ub1 standard error, sCTAC) and - 4.6 \ub1 0.9 % (MRAC), and 1.0 \ub1 0.7 % (sCTAC) and - 4.3 \ub1 0.8 % (MRAC) in SUV mean . The sCTAC was statistically equivalent to CTAC within a \ub1 3.5 % equivalence margin for SUV max and SUV mean (p= 0.007 and p= 0.002), whereas the MRAC was not (p= 0.88 and p= 0.83). Conclusion: Attenuation correction using this radiotherapy ZTE-based sCT algorithm was substantially more accurate than current MRAC methods with only a 40 s increase in MR acquisition time. This did not impact tumour delineation but did significantly improve the accuracy of whole-image and tumour SUV measurements, which were clinically equivalent to CTAC. This suggests PET images reconstructed with sCTAC would enable accurate quantitative PET images to be acquired on a PET-MR scanner

    A Study of the PDGF Signaling Pathway with PRISM

    Get PDF
    In this paper, we apply the probabilistic model checker PRISM to the analysis of a biological system -- the Platelet-Derived Growth Factor (PDGF) signaling pathway, demonstrating in detail how this pathway can be analyzed in PRISM. We show that quantitative verification can yield a better understanding of the PDGF signaling pathway.Comment: In Proceedings CompMod 2011, arXiv:1109.104

    A False Start in the Race Against Doping in Sport: Concerns With Cycling’s Biological Passport

    Get PDF
    Professional cycling has suffered from a number of doping scandals. The sport’s governing bodies have responded by implementing an aggressive new antidoping program known as the biological passport. Cycling’s biological passport marks a departure from traditional antidoping efforts, which have focused on directly detecting prohibited substances in a cyclist’s system. Instead, the biological passport tracks biological variables in a cyclist’s blood and urine over time, monitoring for fluctuations that are thought to indirectly reveal the effects of doping. Although this method of indirect detection is promising, it also raises serious legal and scientific concerns. Since its introduction, the cycling community has debated the reliability of indirect biological-passport evidence and the clarity, consistency, and transparency of its use in proving doping violations. Such uncertainty undermines the legitimacy of finding cyclists guilty of doping based on this indirect evidence alone. Antidoping authorities should address these important concerns before continuing to pursue doping sanctions against cyclists solely on the basis of their biological passports

    Characterization of 30 76^{76}Ge enriched Broad Energy Ge detectors for GERDA Phase II

    Get PDF
    The GERmanium Detector Array (GERDA) is a low background experiment located at the Laboratori Nazionali del Gran Sasso in Italy, which searches for neutrinoless double beta decay of 76^{76}Ge into 76^{76}Se+2e−^-. GERDA has been conceived in two phases. Phase II, which started in December 2015, features several novelties including 30 new Ge detectors. These were manufactured according to the Broad Energy Germanium (BEGe) detector design that has a better background discrimination capability and energy resolution compared to formerly widely-used types. Prior to their installation, the new BEGe detectors were mounted in vacuum cryostats and characterized in detail in the HADES underground laboratory in Belgium. This paper describes the properties and the overall performance of these detectors during operation in vacuum. The characterization campaign provided not only direct input for GERDA Phase II data collection and analyses, but also allowed to study detector phenomena, detector correlations as well as to test the strength of pulse shape simulation codes.Comment: 29 pages, 18 figure

    The first search for bosonic super-WIMPs with masses up to 1 MeV/c2^2 with GERDA

    Get PDF
    We present the first search for bosonic super-WIMPs as keV-scale dark matter candidates performed with the GERDA experiment. GERDA is a neutrinoless double-beta decay experiment which operates high-purity germanium detectors enriched in 76^{76}Ge in an ultra-low background environment at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN in Italy. Searches were performed for pseudoscalar and vector particles in the mass region from 60 keV/c2^2 to 1 MeV/c2^2. No evidence for a dark matter signal was observed, and the most stringent constraints on the couplings of super-WIMPs with masses above 120 keV/c2^2 have been set. As an example, at a mass of 150 keV/c2^2 the most stringent direct limits on the dimensionless couplings of axion-like particles and dark photons to electrons of gae<3⋅10−12g_{ae} < 3 \cdot 10^{-12} and α′/α<6.5⋅10−24{\alpha'}/{\alpha} < 6.5 \cdot 10^{-24} at 90% credible interval, respectively, were obtained.Comment: 6 pages, 3 figures, submitted to Physical Review Letters, added list of authors, updated ref. [21

    A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios

    Full text link
    The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, −(q/m)p/(q/m)pˉ-(q/m)_{\mathrm{p}}/(q/m)_{\bar{\mathrm{p}}} = 1.000 000 000 003(16)1.000\,000\,000\,003 (16), is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of 1.96⋅10−27 1.96\cdot10^{-27}\,GeV (C..L.. 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEPcc_\text{cc}) for antimatter to a level of ∣αg−1∣<1.8⋅10−7|\alpha_{g}-1| < 1.8 \cdot 10^{-7}, and enables the first differential test of the WEPcc_\text{cc} using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEPcc_\text{cc}-violating coefficient to ∣αg,D−1∣<0.030|\alpha_{g,D}-1|<0.030
    • …
    corecore