45 research outputs found

    Analysis of the Origin of Atypical Scanning Laser Polarimetry Patterns by Polarization-Sensitive Optical Coherence Tomography

    Get PDF
    PURPOSE. To analyze the physical origin of atypical scanning laser polarimetry (SLP) patterns. To compare polarization-sensitive optical coherence tomography (PS-OCT) scans to SLP images. To present a method to obtain pseudo-SLP images by PS-OCT that are free of atypical artifacts. METHODS. Forty-one eyes of healthy subjects, subjects with suspected glaucoma, and patients with glaucoma were imaged by SLP (GDx VCC) and a prototype spectral domain PS-OCT system. The PS-OCT system acquires three-dimensional (3D) datasets of intensity, retardation, and optic axis orientation simultaneously within 3 seconds. B-scans of intensity and retardation and en face maps of retinal nerve fiber layer (RNFL) retardation were derived from the 3D PS-OCT datasets. Results were compared with those obtained by SLP. RESULTS. Twenty-two eyes showed atypical retardation patterns, and 19 eyes showed normal patterns. From the 22 atypical eyes, 15 showed atypical patterns in both imaging modalities, five were atypical only in SLP images, and two were atypical only in PS-OCT images. In most (15 of 22) atypical cases, an increased penetration of the probing beam into the birefringent sclera was identified as the source of atypical patterns. In such cases, the artifacts could be eliminated in PS-OCT images by depth segmentation and exclusion of scleral signals. CONCLUSIONS. PS-OCT provides deeper insight into the contribution of different fundus layers to SLP images. Increased light penetration into the sclera can distort SLP retardation patterns of the RNFL. (Invest Ophthalmol Vis Sci. 2008;49:5366 -5372

    Dissecting mitosis by RNAi in Drosophila tissue culture cells

    Get PDF
    Here we describe a detailed methodology to study the function of genes whose products function during mitosis by dsRNA-mediated interference (RNAi) in cultured cells of Drosophila melanogaster. This procedure is particularly useful for the analysis of genes for which genetic mutations are not available or for the dissection of complicated phenotypes derived from the analysis of such mutants. With the advent of whole genome sequencing it is expected that RNAi-based screenings will be one method of choice for the identification and study of novel genes involved in particular cellular processes. In this paper we focused particularly on the procedures for the proper phenotypic analysis of cells after RNAi-mediated depletion of proteins required for mitosis, the process by which the genetic information is segregated equally between daughter cells. We use RNAi of the microtubule-associated protein MAST/Orbit as an example for the usefulness of the technique

    Dual Role of Topoisomerase II in Centromere Resolution and Aurora B Activity

    Get PDF
    Chromosome segregation requires sister chromatid resolution. Condensins are essential for this process since they organize an axial structure where topoisomerase II can work. How sister chromatid separation is coordinated with chromosome condensation and decatenation activity remains unknown. We combined four-dimensional (4D) microscopy, RNA interference (RNAi), and biochemical analyses to show that topoisomerase II plays an essential role in this process. Either depletion of topoisomerase II or exposure to specific anti-topoisomerase II inhibitors causes centromere nondisjunction, associated with syntelic chromosome attachments. However, cells degrade cohesins and timely exit mitosis after satisfying the spindle assembly checkpoint. Moreover, in topoisomerase II–depleted cells, Aurora B and INCENP fail to transfer to the central spindle in late mitosis and remain tightly associated with centromeres of nondisjoined sister chromatids. Also, in topoisomerase II–depleted cells, Aurora B shows significantly reduced kinase activity both in S2 and HeLa cells. Codepletion of BubR1 in S2 cells restores Aurora B kinase activity, and consequently, most syntelic attachments are released. Taken together, our results support that topoisomerase II ensures proper sister chromatid separation through a direct role in centromere resolution and prevents incorrect microtubule–kinetochore attachments by allowing proper activation of Aurora B kinase

    High Resolution Spectral Domain Optical Coherence Tomography (SD-OCT) in Multiple Sclerosis: The First Follow Up Study over Two Years

    Get PDF
    “Non-invasive, faster and less expensive than MRI” and “the eye is a window to the brain” are recent slogans promoting optical coherence tomography (OCT) as a new surrogate marker in multiple sclerosis (MS). Indeed, OCT allows for the first time a non-invasive visualization of axons of the central nervous system (CNS). Reduction of retina nerve fibre layer (RNFL) thickness was suggested to correlate with disease activity and duration. However, several issues are unclear: Do a few million axons, which build up both optic nerves, really resemble billions of CNS neurons? Does global CNS damage really result in global RNFL reduction? And if so, does global RNFL reduction really exist in all MS patients, and follow a slowly but steadily ongoing pattern? How can these (hypothesized) subtle global RNFL changes be reliably measured and separated from the rather gross RNFL changes caused by optic neuritis? Before generally being accepted, this interpretation needs further critical and objective validation.We prospectively studied 37 MS patients with relapsing remitting (n = 27) and secondary progressive (n = 10) course on two occasions with a median interval of 22.4±0.5 months [range 19–27]. We used the high resolution spectral domain (SD-)OCT with the Spectralis 3.5 mm circle scan protocol with locked reference images and eye tracking mode. Patients with an attack of optic neuritis within 12 months prior to the onset of the study were excluded.Although the disease was highly active over the observation period in more than half of the included relapsing remitting MS patients (19 patients/32 relapses) and the initial RNFL pattern showed a broad range, from normal to markedly reduced thickness, no significant changes between baseline and follow-up examinations could be detected.These results show that caution is required when using OCT for monitoring disease activity and global axonal injury in MS

    Albiglutide and cardiovascular outcomes in patients with type 2 diabetes and cardiovascular disease (Harmony Outcomes): a double-blind, randomised placebo-controlled trial

    Get PDF
    Background: Glucagon-like peptide 1 receptor agonists differ in chemical structure, duration of action, and in their effects on clinical outcomes. The cardiovascular effects of once-weekly albiglutide in type 2 diabetes are unknown. We aimed to determine the safety and efficacy of albiglutide in preventing cardiovascular death, myocardial infarction, or stroke. Methods: We did a double-blind, randomised, placebo-controlled trial in 610 sites across 28 countries. We randomly assigned patients aged 40 years and older with type 2 diabetes and cardiovascular disease (at a 1:1 ratio) to groups that either received a subcutaneous injection of albiglutide (30–50 mg, based on glycaemic response and tolerability) or of a matched volume of placebo once a week, in addition to their standard care. Investigators used an interactive voice or web response system to obtain treatment assignment, and patients and all study investigators were masked to their treatment allocation. We hypothesised that albiglutide would be non-inferior to placebo for the primary outcome of the first occurrence of cardiovascular death, myocardial infarction, or stroke, which was assessed in the intention-to-treat population. If non-inferiority was confirmed by an upper limit of the 95% CI for a hazard ratio of less than 1·30, closed testing for superiority was prespecified. This study is registered with ClinicalTrials.gov, number NCT02465515. Findings: Patients were screened between July 1, 2015, and Nov 24, 2016. 10 793 patients were screened and 9463 participants were enrolled and randomly assigned to groups: 4731 patients were assigned to receive albiglutide and 4732 patients to receive placebo. On Nov 8, 2017, it was determined that 611 primary endpoints and a median follow-up of at least 1·5 years had accrued, and participants returned for a final visit and discontinuation from study treatment; the last patient visit was on March 12, 2018. These 9463 patients, the intention-to-treat population, were evaluated for a median duration of 1·6 years and were assessed for the primary outcome. The primary composite outcome occurred in 338 (7%) of 4731 patients at an incidence rate of 4·6 events per 100 person-years in the albiglutide group and in 428 (9%) of 4732 patients at an incidence rate of 5·9 events per 100 person-years in the placebo group (hazard ratio 0·78, 95% CI 0·68–0·90), which indicated that albiglutide was superior to placebo (p<0·0001 for non-inferiority; p=0·0006 for superiority). The incidence of acute pancreatitis (ten patients in the albiglutide group and seven patients in the placebo group), pancreatic cancer (six patients in the albiglutide group and five patients in the placebo group), medullary thyroid carcinoma (zero patients in both groups), and other serious adverse events did not differ between the two groups. There were three (<1%) deaths in the placebo group that were assessed by investigators, who were masked to study drug assignment, to be treatment-related and two (<1%) deaths in the albiglutide group. Interpretation: In patients with type 2 diabetes and cardiovascular disease, albiglutide was superior to placebo with respect to major adverse cardiovascular events. Evidence-based glucagon-like peptide 1 receptor agonists should therefore be considered as part of a comprehensive strategy to reduce the risk of cardiovascular events in patients with type 2 diabetes. Funding: GlaxoSmithKline

    Thirty-Five Years Trend in the Prevalence of Refractive Error in Austrian Conscripts based on 1.5 million participants

    No full text
    Background: To quantify the current burden of myopia and hyperopia in Austrian young men and the time trend of myopia in the past 35 years by individual and social correlates. Method: We included data on all Austrian military conscripts from 1983 to 2017 (n=1 507 063) from six medical investigation stations. Young men provided data on education, weight and height for calculating body mass index, blood pressure and resting heart rate. Non-cycloplegic refractions were measured by an autorefractometer. Spherical equivalent was calculated by standard formula (sphere+cylinder/2, unit dioptres (D)). Myopic refractive error was defined as 0.5 D. Results: The largest burden of refractive error in Austria is myopia, which rose from 13.8% to 24.4% over 35 years, with less than 5% hyperopic population. Over time, the prevalence of myopia was constantly lower yet increased more rapidly among those with low education levels (11.4%–21.7%) compared with those with higher education (24.5%–29.6%) in all medical investigation stations. We found consistent associations of some unfavourable health indicators (underweight: ORs 1.1–1.4, higher resting heart rate: all p trend <0.001) with higher myopia prevalence, which point towards lifestyle factors playing an important role in the development of myopia. Conclusion: Primary preventive measures are needed to curb the observed trend in myopia among Austrian young men. Future research should investigate the impact of modifiable factors on myopia development and progression, particularly lifestyle factors that are dramatically shifting

    PLOS One / Compensation for Retinal Vessel Density Reduces the Variation of Circumpapillary RNFL in Healthy Subjects

    No full text
    This work intends to assess circumpapillary retinal vessel density (RVD) at a 3.46 mm diameter circle and correlate it with circumpapillary retinal nerve fiber layer (RNFL) thickness measured with Fourier-Domain Optical Coherence Tomography. Furthermore, it aims to evaluate the reduction of intersubject variability of RNFL when considering RVD as a source of information for RNFL distribution. For that, 106 healthy subjects underwent circumpapillary RNFL measurement. Using the scanning laser ophthalmoscope fundus image, thickness and position of retinal vessels were assessed and integrated in a 256-sector RVD profile. The relationship between local RVD value and local RNFL thickness was modeled by linear regression. RNFL was then compensated for RVD variation by regression formulas. A strong statistically significant intrasubject correlation was found for all subjects between RVD and RNFL profiles (mean R = 0.769). In the intersubject regression analysis, 247 of 256 RNFL sectors showed a statistically significant positive correlation with RVD (mean R = 0.423). RVD compensation of RNFL resulted in a relative reduction of up to 20% of the intersubject variance. In conclusion, RVD in a 3.46mm circle has a clinically relevant influence on the RNFL distribution. RVD may be used to develop more individualized normative values for RNFL measurement, which might improve early diagnosis of glaucoma.(VLID)491218

    A Functional Regression Model of the Retinal Nerve Fiber Layer Thickness in Healthy Subjects

    No full text
    Purpose: A new functional regression model is presented to explain the intersubject variability of the circumpapillary retinal nerve fiber layer (RNFL) thickness in healthy subjects. Methods: To evaluate the functional regression approach we used data from 202 healthy volunteers, divided equally into training samples (TS) and validation samples (VS). Covariates included RNFL, fovea distance, fovea angle, optic disk ratio, orientation and area provided by Fourier-domainoptical coherence tomography, age, and refractive error. Root mean square errors (RMSE) were calculated for each of the 256 sectors and for the 12 clock-hour sectors in the TS and VS and were compared to the RMSE of the previous model and the standard deviation of the raw data. Results: With the functional regression approach, we were able to explain on average 27.4% of the variation in the TS and 25.1% of the variation in the VS. The new model performed better compared to a multivariate linear regression model. It performed best in the superior-temporal and inferior-temporal clock-hour sectors where the percentage of RMSE reduction ranged between 26.3% and 44.1% for the TS and between 20.6% and 35.4% for the VS. Conclusions: The new functional regression approach improves on the multivariate linear regression model and allows an even larger reduction of the amount of intersubject variability, while at the same time using a substantially smaller number of parameters to be estimated. Translational Relevance: The demonstrated reduction of interindividual variation is expected to translate into an improved diagnostic separation between healthy and glaucomatous subjects, but this remains to be demonstrated in further studies.(VLID)467278

    Optic nerve head morphology in primary open-angle glaucoma and nonarteritic anterior ischemic optic neuropathy measured with spectral domain optical coherence tomography

    No full text
    Purpose Optic nerve head (ONH) parameters as well as circumpapillary retinal nerve fibre layer (RNFL) thickness values measured with two different spectral domain optical coherence tomography (SDOCT) machines (Spectralis® and Cirrus® OCT) have been compared between two patient groups, primary openangle glaucoma (POAG), nonarteritic anterior ischaemic optic neuropathy (NAION) and healthy controls. A comparison of the performance of the two OCT machines was made. Methods Twenty healthy controls, 20 POAG and 20 NAION patients with comparable visual field defects were included. Comparison between groups was made using anova and post hoc ttests. To evaluate the diagnostic power of OCT to differentiate POAG from NAION, a stepwise linear regression analysis of the rimRNFL correlation with adjusting covariates (optic disc area and age) was performed. Based on the regression formula, the area under the receiver operator characteristic (AUROC) was calculated. Results Both glaucoma and NAION patients showed significantly smaller global RNFL thickness values compared to healthy subjects in ttests (p < 0.001), while only patients with glaucoma showed significantly smaller global ONH parameters for both devices compared to healthy subjects (p < 0.001). Correlation between global ONH parameters was highly statistically significant (r = 0.93), whereas in ttest a statistically significant difference between the two machines was detected (p < 0.001). Area under the receiver operator characteristic revealed a similarly good discrimination between glaucoma and NAION for Spectralis® (0.980) and Cirrus® OCT (0.945). Conclusion NAION patients have similar RNFL thickness values as do glaucomatous eyes, whereas ONH parameters in NAION eyes were similar to those seen in healthy controls. This difference might help discriminating between these two different disease conditions in a chronic disease stadium, and in this regard, none of the two OCT machines performed better.(VLID)339640
    corecore