43 research outputs found

    Surgical and Hardware-Related Adverse Events of Deep Brain Stimulation:A Ten-Year Single-Center Experience

    Get PDF
    INTRODUCTION: Although deep brain stimulation (DBS) is effective for treating a number of neurological and psychiatric indications, surgical and hardware-related adverse events (AEs) can occur that affect quality of life. This study aimed to give an overview of the nature and frequency of those AEs in our center and to describe the way they were managed. Furthermore, an attempt was made at identifying possible risk factors for AEs to inform possible future preventive measures. MATERIALS AND METHODS: Patients undergoing DBS-related procedures between January 2011 and July 2020 were retrospectively analyzed to inventory AEs. The mean follow-up time was 43 ± 31 months. Univariate logistic regression analysis was used to assess the predictive value of selected demographic and clinical variables. RESULTS: From January 2011 to July 2020, 508 DBS-related procedures were performed including 201 implantations of brain electrodes in 200 patients and 307 implantable pulse generator (IPG) replacements in 142 patients. Surgical or hardware-related AEs following initial implantation affected 40 of 200 patients (20%) and resolved without permanent sequelae in all instances. The most frequent AEs were surgical site infections (SSIs) (9.95%, 20/201) and wire tethering (2.49%, 5/201), followed by hardware failure (1.99%, 4/201), skin erosion (1.0%, 2/201), pain (0.5%, 1/201), lead migration (0.52%, 2/386 electrode sites), and hematoma (0.52%, 2/386 electrode sites). The overall rate of AEs for IPG replacement was 5.6% (17/305). No surgical, ie, staged or nonstaged, electrode fixation, or patient-related risk factors were identified for SSI or wire tethering. CONCLUSIONS: Major AEs including intracranial surgery-related AEs or AEs requiring surgical removal or revision of hardware are rare. In particular, aggressive treatment is required in SSIs involving multiple sites or when Staphylococcus aureus is identified. For future benchmarking, the development of a uniform reporting system for surgical and hardware-related AEs in DBS surgery would be useful

    Planck pre-launch status : The Planck mission

    Get PDF
    Peer reviewe

    Quantification of perifosine, an alkylphosphocholine anti-tumour agent, in plasma by pneumatically assisted electrospray tandem mass spectrometry coupled with high-performance liquid chromatography

    No full text
    An HPLC assay with tandem mass spectrometric detection in the positive-ion Turbo-Ion-Spray((TM)) (TISP) mode for the fast and sensitive determination of perifosine ((I), D-21266) in human plasma was developed, utilising the structural analogue, miltefosine ((II), D-18506), as internal standard. Automated solid-phase extraction of diluted plasma samples, based on 250-μl plasma aliquots, at pH 6.5, allowed a reliable quantification of perifosine down to 4 ng/ml. Injection of 200 μl of plasma extracts onto a 100x3 mm normal-phase analytical column at a flow-rate of 0.5 ml/min provided retention-times of 2.4 and 2.1 min for perifosine (I) and the internal standard (II), respectively. The standard curves were linear from 4 to 2000 ng/ml using weighted linear regression analysis (1/Y2). The inter-assay and intra-assay accuracies for the calibration standards were within +0.9% and -0.2%, exhibiting precisions (C.V.) of ±6.5 and ±7.3%, respectively. Up to 100 unknowns may be analysed each 24 h per analyst. Copyright (C) 1999 Elsevier Science B.V

    Lumbar spinal stenosis in a patient with complex spinal dysraphism caused by a supplementary midline muscle:A case report

    No full text
    Background: The clinical tethered cord syndrome (TCS) can become symptomatic during adulthood, known as adult tethered cord syndrome (ATCS). Distinguishing ATCS from neurogenic claudication attributed to lumbar spinal stenosis may pose a clinical challenge. Case Description: A 66-year-old male with an underlying complex occult spinal dysraphism (OSD) presented with new onset of lower back and bilateral leg pain plus neurogenic claudication. Magnetic resonance imaging documented OSD, and lumbar spinal stenosis (LSS) attributed to a supplementary midline muscle. Following decompressive surgery for LSS without untethering the ATCS, the patient's symptoms resolved. Conclusion: A patient with OSD and ATCS with LSS due to a supplementary midline muscle presented with new onset of neurogenic claudication. Surgical decompression of the LSS by removing the supplementary midline muscle resolved patients' symptoms
    corecore