19 research outputs found

    Status of the Micro Vertex Detector of the Compressed Baryonic Matter Experiment

    Get PDF
    The CBM experiment will investigate heavy-ion collisions at beam energies from 8 to 45 AGeV at the future accelerator facility FAIR. The goal of the experiment is to study the QCD phase diagram in the vincinity of the QCD critical point. To do so, CBM aims at measuring rare probes among them open charm. In order to identify those rare and short lived particles despite the rich combinatorial background generated in heavy ion collisions, a micro vertex detector (MVD) providing an unprecedented combination of high rate capability and radiation hardness, very light material budget and excellent granularity is required. In this work, we will discuss the concept of this detector and summarize the status of the R&D

    Effectiveness of a ‘do not interrupt’ vest intervention to reduce medication errors during medication administration: a multicenter cluster randomized controlled trial

    No full text
    International audienceAbstract Background The use of a ‘do not interrupt’ vest during medication administration rounds is recommended but there have been no controlled randomized studies to evaluate its impact on reducing administration errors. We aimed to evaluate the impact of wearing such a vest on reducing such errors. The secondary objectives were to evaluate the types and potential clinical impact of errors, the association between errors and several risk factors (such as interruptions), and nurses’ experiences. Methods This was a multicenter, cluster, controlled, randomized study (March–July 2017) in 29 adult units (4 hospitals). Data were collected by direct observation by trained observers. All nurses from selected units were informed. A ‘Do not interrupt’ vest was implemented in all units of the experimental group. A poster was placed at the entrance of these units to inform patients and relatives. The main outcome was the administration error rate (number of Opportunities for Error (OE), calculated as one or more errors divided by the Total Opportunities for Error (TOE) and multiplied by 100). Results We enrolled 178 nurses and 1346 patients during 383 medication rounds in 14 units in the experimental group and 15 units in the control group. During the intervention period, the administration error rates were 7.09% (188 OE with at least one error/2653 TOE) for the experimental group and 6.23% (210 OE with at least one error/3373 TOE) for the control group ( p = 0.192). Identified risk factors (patient age, nurses’ experience, nurses’ workload, unit exposition, and interruption) were not associated with the error rate. The main error type observed for both groups was wrong dosage-form. Most errors had no clinical impact for the patient and the interruption rates were 15.04% for the experimental group and 20.75% for the control group. Conclusions The intervention vest had no impact on medication administration error or interruption rates. Further studies need to be performed taking into consideration the limitations of our study and other risk factors associated with other interventions, such as nurse’s training and/or a barcode system. Trial registration The PERMIS study protocol (V2–1, 11/04/2017) was approved by institutional review boards and ethics committees (CPP Ile de France number 2016-A00211–50, CNIL 21/03/2017, CCTIRS 11/04/2016). It is registered at ClinicalTrials.gov (registration number: NCT03062852 , date of first registration: 23/02/2017)

    Relationship between serotypes, disease characteristics and 30-day mortality in adults with invasive pneumococcal disease

    No full text
    International audienc

    Sotrovimab therapy elicits antiviral activities against Omicron BQ.1.1 and XBB.1.5 in sera of immunocompromised patients [letter]

    No full text
    International audienc

    Persistent headaches one year after bacterial meningitis: prevalence, determinants and impact on quality of life

    No full text
    International audienceBackground: Little is known on headaches long-term persistence after bacterial meningitis and on their impact on patients' quality of life.Methods: In an ancillary study of the French national prospective cohort of community-acquired bacterial meningitis in adults (COMBAT) conducted between February 2013 and July 2015, we collected self-reported headaches before, at onset, and 12 months (M12) after meningitis. Determinants of persistent headache (PH) at M12, their association with M12 quality of life (SF 12), depression (Center for Epidemiologic Studies Depression Scale) and neuro-functional disability were analysed.Results: Among the 277 alive patients at M12 87/274 (31.8%), 213/271 (78.6%) and 86/277 (31.0%) reported headaches before, at the onset, and at M12, respectively. In multivariate analysis, female sex (OR: 2.75 [1.54-4.90]; p < 0.001), pre-existing headaches before meningitis (OR: 2.38 [1.32-4.30]; p < 0.01), higher neutrophilic polynuclei percentage in the CSF of the initial lumbar puncture (OR: 1.02 [1.00-1.04]; p < 0.05), and brain abscess during the initial hospitalisation (OR: 8.32 [1.97-35.16]; p < 0.01) were associated with M12 persistent headaches. Neither the responsible microorganism, nor the corticoids use were associated with M12 persistent headaches. M12 neuro-functional disability (altered Glasgow Outcome Scale; p < 0.01), M12 physical handicap (altered modified Rankin score; p < 0.001), M12 depressive symptoms (p < 0.0001), and M12 altered physical (p < 0.05) and mental (p < 0.0001) qualities of life were associated with M12 headaches.Conclusion: Persistent headaches are frequent one year after meningitis and are associated with quality of life alteration

    One-Year Sequelae and Quality of Life in Adults with Meningococcal Meningitis: Lessons from the COMBAT Multicentre Prospective Study

    No full text
    Trial registration: ClinicalTrial.Gov identification number NCT01730690.International audienceIntroduction: COMBAT is a prospective, multicentre cohort study that enrolled consecutive adults with community-acquired bacterial meningitis (CABM) in 69 participating centres in France between February 2013 and July 2015 and followed them for 1 year.Methods: Patients aged at least 18 years old, hospitalised with CABM were followed during their hospitalisation and then contacted by phone 12 months after enrolment. Here we present the prevalence of sequelae at 12 months in a subgroup of patients with meningococcal meningitis.Results: Five of the 111 patients with meningococcal meningitis died during initial hospitalisation and two died between discharge and 12 months, leaving 104 patients alive 1 year after enrolment, 71 of whom provided 12-month follow-up data. The median age was 30.0 years and 54.1% of the patients had no identified risk factor for meningitis. More than 30% reported persistent headache, more than 40% were not satisfied with their sleep and 10% had concentration difficulties. Hearing loss was present in about 15% of the patients and more than 30% had depressive symptoms. About 13% of the patients with a previous professional activity had not resumed work. On the SF-12 Health Survey, almost 50% and 30% had physical component or mental component scores lower than the 25th percentile of the score distribution in the French general population. There was a non-significant improvement in the patients' disability scores from hospital discharge to 12 months (p = 0.16), but about 10% of the patients had residual disability.Conclusions: Although most patients in our cohort survive meningococcal meningitis, the long-term burden is substantial and therefore it is important to ensure a prolonged follow-up of survivors and to promote preventive strategies, including vaccination

    Increased risk of severe COVID-19 in hospitalized patients with SARS-CoV-2 Alpha variant infection: a multicentre matched cohort study

    No full text
    International audienceBackground: The impact of the variant of concern (VOC) Alpha on the severity of COVID-19 has been debated. We report our analysis in France.Methods: We conducted an exposed/unexposed cohort study with retrospective data collection, comparing patients infected by VOC Alpha to contemporaneous patients infected by historical lineages. Participants were matched on age (± 2.5 years), sex and region of hospitalization. The primary endpoint was the proportion of hospitalized participants with severe COVID-19, defined as a WHO-scale > 5 or by the need of a non-rebreather mask, occurring up to day 29 after admission. We used a logistic regression model stratified on each matched pair and accounting for factors known to be associated with the severity of the disease.Results: We included 650 pairs of patients hospitalized between Jan 1, 2021, and Feb 28, 2021, in 47 hospitals. Median age was 70 years and 61.3% of participants were male. The proportion of participants with comorbidities was high in both groups (85.0% vs 90%, p = 0.004). Infection by VOC Alpha was associated with a higher odds of severe COVID-19 (41.7% vs 38.5%-aOR = 1.33 95% CI [1.03-1.72]).Conclusion: Infection by the VOC Alpha was associated with a higher odds of severe COVID-19

    International Large Detector: Interim Design Report

    No full text
    The ILD detector is proposed for an electron-positron collider with collision centre-of-mass energies from 90~\GeV~to about 1~\TeV. It has been developed over the last 10 years by an international team of scientists with the goal to design and eventually propose a fully integrated detector, primarily for the International Linear Collider, ILC. In this report the fundamental ideas and concepts behind the ILD detector are discussed and the technologies needed for the realisation of the detector are reviewed. The document starts with a short review of the science goals of the ILC, and how the goals can be achieved today with the detector technologies at hand. After a discussion of the ILC and the environment in which the experiment will take place, the detector is described in more detail, including the status of the development of the technologies foreseen for each subdetector. The integration of the different sub-systems into an integrated detector is discussed, as is the interface between the detector and the collider. This is followed by a concise summary of the benchmarking which has been performed in order to find an optimal balance between performance and cost. To the end the costing methodology used by ILD is presented, and an updated cost estimate for the detector is presented. The report closes with a summary of the current status and of planned future actions

    The ILD detector at the ILC

    No full text
    The International Large Detector, ILD, is a detector concept which has been developed for the electron-positron collider ILC. The detector has been optimized for precision physics in a range of energies between 90 GeV and 1 TeV. ILD features a high precision, large volume combined silicon and gaseous tracking system, together with a high granularity calorimeter, all inside a 3.5 T solenoidal magnetic field. The paradigm of particle flow has been the guiding principle of the design of ILD. In this document the required performance of the detector, the proposed implementation and the readiness of the different technologies needed for the implementation are discussed. This is done in the framework of the ILC collider proposal, now under consideration in Japan, and includes site specific aspects needed to build and operate the detector at the proposed ILC site in Japan
    corecore