65 research outputs found

    Patient outcomes and characteristics in a contemporary quaternary Canadian cardiac intensive care unit

    Get PDF
    BACKGROUND: The modern-day cardiac intensive care unit (CICU) has evolved to care for patients with acute critical cardiac illness. We describe the current population of cardiac patients in a quaternary CICU. METHODS: Consecutive CICU patients admitted to the CICU at the Toronto General Hospital from 2014 to 2020 were studied. Patient demographics, admission diagnosis, critical care resources, complications, in-hospital mortality, and CICU and hospital length of stay were recorded. RESULTS: A total of 8865 consecutive admissions occurred, with a median age of 64.9 years. The most common primary cardiac diagnoses were acute decompensated heart failure (17.8%), non ST-elevation myocardial infarction (16.8%), ST-elevation myocardial infarction (15.5%), and arrhythmias (14.7%). Cardiogenic shock was seen in 13.2%, and out-of-hospital cardiac arrest in 4.1%. A noncardiovascular admission diagnosis accounted for 13.9% of the cases. Over the period studied, rates of admission were higher for cardiogenic shock (P < 0.001 for trend), with a higher use of critical care resources. Additionally, rates of admission were higher in female patients and those who had chronic kidney disease and diabetes. The in-hospital mortality rate of all CICU admissions was 13.2%, and it was highest in those with noncardiac conditions, compared to the rate in those with cardiac diagnoses (29.4% vs 10.6%, P < 0.001). CONCLUSIONS: Given the trends of higher acuity of patients with cardiac critical illness, with higher use of critical care resources, education streams for critical care within cardiology, and alternative pathways of care for patients who have lower-acuity cardiac disease remain imperative to manage this evolving population

    Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC

    Get PDF
    DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6  ×  6  ×  6 m 3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties

    Parkinson's Disease: Basic Pathomechanisms and a Clinical Overview

    Get PDF
    PD is a common and a debilitating degenerative movement disorder. The number of patients is increasing worldwide and as yet there is no cure for the disease. The majority of existing treatments target motor symptom control. Over the last two decades the impact of the genetic contribution to PD has been appreciated. Significant discoveries have been made, which have advanced our understanding of the pathophysiological and molecular basis of PD. In this chapter we outline current knowledge of the clinical aspects of PD and the basic mechanistic understanding

    Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network

    Get PDF
    Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation

    Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network

    Get PDF
    Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on experimental data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between experimental data and simulation

    Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC

    Get PDF
    The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at the end of the H4 beamline. This detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment (DUNE), which will be constructed at the Sandford Underground Research Facility (SURF) in Lead, South Dakota, U.S.A. The ProtoDUNE-SP detector incorporates full-size components as designed for DUNE and has an active volume of 7 × 6 × 7.2 m3. The H4 beam delivers incident particles with well-measured momenta and high-purity particle identification. ProtoDUNE-SP's successful operation between 2018 and 2020 demonstrates the effectiveness of the single-phase far detector design. This paper describes the design, construction, assembly and operation of the detector components

    Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

    Get PDF
    The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3σ (5σ) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3σ level with a 100 kt-MW-yr exposure for the maximally CP-violating values \delta_{\rm CP}} = \pm\pi/2. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest

    Searching for solar KDAR with DUNE

    Get PDF

    Measurement of the ratio of the production cross sections times branching fractions of B c ±  → J/ψπ ± and B± → J/ψK ± and ℬ B c ± → J / ψ π ± π ± π ∓ / ℬ B c ± → J / ψ π ± B(Bc±J/ψπ±π±π)/B(Bc±J/ψπ±) \mathrm{\mathcal{B}}\left({\mathrm{B}}_{\mathrm{c}}^{\pm}\to \mathrm{J}/\psi {\pi}^{\pm }{\pi}^{\pm }{\pi}^{\mp}\right)/\mathrm{\mathcal{B}}\left({\mathrm{B}}_{\mathrm{c}}^{\pm}\to \mathrm{J}/\psi {\pi}^{\pm}\right) in pp collisions at s = 7 s=7 \sqrt{s}=7 TeV

    Full text link
    corecore