62 research outputs found
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
pb to the WIMP-nucleon cross-section.Comment: Submitted to Astroparticle Physic
Peroxide-based route for the synthesis of zinc titanate powder
In this work the thermodynamical solubility diagrams of zinc and titanium hydroxides
were reviewed in order to determine the conditions for maximum degree of phase composition
homogenization of precipitates. Experimental investigation of dependency of titanium peroxohydroxide
solubility on solution acidity has been carried out and coprecipitation of zinc ions has been
studied. It was concluded that precipitation by constant addition of mixed salts and base solutions
into the mother liquor with constant acidity of pH 8.5 allows maximizing homogenization of
precipitate composition. Thermal treatment process of mixed zinc and titanium hydroxides
coprecipitated with hydrogen peroxide was studied using thermogravimetric analysis, differential
thermal analysis and X-ray diffraction methods. It was found that precipitates of co-precipitated
mixtures of zinc and titanium hydroxides contained impurities of salts precursors of the Zn
(NO3)2 and TiOCl2 at a level of 1%. The experimental data demonstrate the influence of hydrogen
peroxide on crystal growth rate of the zinc titanate during thermal treatment. The temperature
ranges and kinetic parameters of hydroxide mixture dehydration, decomposition of the titanium
peroxohydroxide and precursor impurities were determined
The MIGDAL experiment: measuring a rare atomic process to aid the search for dark matter
We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF4. Initially, pure CF4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator
Projected WIMP sensitivity of the LUX-ZEPLIN dark matter experiment
LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with weakly interacting massive particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6-tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above 1.4 × 10-48cm2 for a 40 GeV/c2 mass WIMP.
Additionally, a 5σ discovery potential is projected, reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of 2.3 × 10−43 cm2 (7.1 × 10−42 cm2) for a 40 GeV/c2
mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020
Search for annual and diurnal rate modulations in the LUX experiment
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth’s motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3±0.2  cpd/keVee/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26  keVee. Between 2 and 6  keVee, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2σ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2  cpd/keVee/tonne amplitude between 2 and 6  keVee.Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.30.2~cpd/keV/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV. Between 2 and 6~keV, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2 tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV/tonne amplitude between 2 and 6~keV
Measurement of the gamma ray background in the Davis Cavern at the Sanford Underground Research Facility
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from γ-rays emitted by 40K and the 238U and 232Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ γ-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of 1.9±0.4~γ cm−2s−1. The resulting activity in the walls of the cavern can be characterised as 220±60~Bq/kg of 40K, 29±15~Bq/kg of 238U, and 13±3~Bq/kg of 232Th
The design, implementation, and performance of the LZ calibration systems
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments
New constraints on ultraheavy dark matter from the LZ experiment
Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV/c2 to a few TeV/c2. Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a reanalysis of the first science run of the LZ experiment, with an exposure of 0.9  tonne×yr, to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 1017  GeV/c2.
Published by the American Physical Society
2024
</jats:sec
- …