1,197 research outputs found

    A novel splicing variant of col2a1 in a fetus with achondrogenesis type ii: Interpretation of pathogenicity of in-frame deletions

    Get PDF
    Achondrogenesis type II (ACG2) is a lethal skeletal dysplasia caused by dominant pathogenic variants in COL2A1. Most of the variants found in patients with ACG2 affect the glycine residue included in the Gly-X-Y tripeptide repeat that characterizes the type II collagen helix. In this study, we reported a case of a novel splicing variant of COL2A1 in a fetus with ACG2. An NGS analysis of fetal DNA revealed a heterozygous variant c.1267-2_1269del located in intron 20/exon 21. The variant occurred de novo since it was not detected in DNA from the blood samples of parents. We generated an appropriate minigene construct to study the effect of the variant detected. The minigene expression resulted in the synthesis of a COL2A1 messenger RNA lacking exon 21, which generated a predicted in-frame deleted protein. Usually, in-frame deletion variants of COL2A1 cause a phenotype such as Kniest dysplasia, which is milder than ACG2. Therefore, we propose that the size and position of an in-frame deletion in COL2A1 may be relevant in determining the phenotype of skeletal dysplasia

    A novel ABCC6 variant causative of pseudoxanthoma elasticum

    Get PDF
    Pseudoxanthoma elasticum is an autosomal recessive heritable disorder caused by mutations in ABCC6. We describetwo siblings showing typical skin lesions and a clinical diagnosis of pseudoxanthoma elasticum. Genetic analysis ofABCC6 revealed a novel homozygous c.4041G > A variant located in the last position of exon 28 that compromises thesplicing donor site, resulting in a shorter messenger RNA. The deletion impairs the nucleotide-binding fold region,which is crucial for ABCC6 function

    Displacement power spectrum measurement of a macroscopic optomechanical system at thermal equilibrium

    Get PDF
    The mirror relative motion of a suspended Fabry-Perot cavity is studied in the frequency range 3-10 Hz. The experimental measurements presented in this paper, have been performed at the Low Frequency Facility, a high finesse optical cavity 1 cm long suspended to a mechanical seismic isolation system identical to that one used in the VIRGO experiment. The measured relative displacement power spectrum is compatible with a system at thermal equilibrium within its environmental. In the frequency region above 3 Hz, where seismic noise contamination is negligible, the measurement distribution is stationary and Gaussian, as expected for a system at thermal equilibrium. Through a simple mechanical model it is shown that: applying the fluctuation dissipation theorem the measured power spectrum is reproduced below 90 Hz and noise induced by external sources are below the measurement.Comment: 11 pages, 9 figures, 2 tables, to be submitte

    A systematic review of community participation measures for people with intellectual disabilities

    Get PDF
    Background: Community participation is considered a fundamental aspect of quality of life and one of the essential goals of services for people with intellectual disabilities (ID), yet there is no agreed way of measuring community participation. Method: Two systematic searches were performed across eight electronic databases to identify measures of community participation and identify validation studies for each measure. Measures were included if they were developed for adults with ID, measured extent of participation and had published information regarding content and psychometric properties. Each measure was evaluated on the basis of psychometric properties and in relation to coverage of nine domains of community participation from the International Classification of Functioning, Disability and Health (ICF). Results: Eleven measures were selected with the quality rating scores varying substantially ranging from 2-11 of a possible 16. Conclusions: The majority of measures were not sufficiently psychometrically tested. Findings suggest a need for the development of a psychometrically robust instrument

    Inertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection

    Get PDF
    In order to achieve full detection sensitivity at low frequencies, the mirrors of interferometric gravitational wave detectors must be isolated from seismic noise. The VIRGO vibration isolator, called 'superattenuator', is fully effective at frequencies above 4 Hz. Nevertheless, the residual motion of the mirror at the mechanical resonant frequencies of the system are too large for the interferometer locking system and must be damped. A multidimensional feedback system, using inertial sensors and digital processing, has been designed for this purpose. An experimental procedure for determining the feedback control of the system has been defined. In this paper a full description of the system is given and experimental results are presented.Comment: 17 pages, 11 figures, accepted for publication on Review of Scientific Instrument

    Monitoring multiple myeloma by idiotype-specific peptide binders of tumor-derived exosomes.

    Get PDF
    Abstract Tumor-derived exosomes (TDEs) play a pivotal role in tumor establishment and progression, and are emerging biomarkers for tumor diagnosis in personalized medicine. To date, there is a lack of efficient technology platforms for exosome isolation and characterization. Multiple myeloma (MM) is an incurable B-cell malignancy due to the rapid development of drug-resistance. MM-released exosomes express the immunoglobulin B-cell receptor (Ig-BCR) of the tumor B-cells, which can be targeted by Idiotype-binding peptides (Id-peptides). In this study, we analyzed the production of MM-released exosomes in the murine 5T33MM multiple myeloma model as biomarkers of tumor growth. To this end, we selected Id-peptides by screening a phage display library using as bait the Ig-BCR expressed by 5T33MM cells. By FACS, the FITC-conjugated Id-peptides detected the MM-released exosomes in the serum of 5T33MM-engrafted mice, levels of which are correlated with tumor progression at an earlier time point compared to serum paraprotein. These results indicate that Id-peptide-based recognition of MM-released exosomes may represent a very sensitive diagnostic approach for clinical evaluation of disease progression

    Natural Course of COVID-19 and Independent Predictors of Mortality.

    Get PDF
    Background: During the SARS-CoV-2 pandemic, several biomarkers were shown to be helpful in determining the prognosis of COVID-19 patients. The aim of our study was to evaluate the prognostic value of N-terminal pro-Brain Natriuretic Peptide (NT-pro-BNP) in a cohort of patients with COVID-19. Methods: One-hundred and seven patients admitted to the Covid Hospital of Messina University between June 2022 and January 2023 were enrolled in our study. The demographic, clinical, biochemical, instrumental, and therapeutic parameters were recorded. The primary outcome was in-hospital mortality. A comparison between patients who recovered and were discharged and those who died during the hospitalization was performed. The independent parameters associated with in-hospital death were assessed by multivariable analysis and a stepwise regression logistic model. Results: A total of 27 events with an in-hospital mortality rate of 25.2% occurred during our study. Those who died during hospitalization were older, with lower GCS and PaO2/FiO2 ratio, elevated D-dimer values, INR, creatinine values and shorter PT (prothrombin time). They had an increased frequency of diagnosis of heart failure (p < 0.0001) and higher NT-pro-BNP values. A multivariate logistic regression analysis showed that higher NT-pro-BNP values and lower PT and PaO2/FiO2 at admission were independent predictors of mortality during hospitalization. Conclusions: This study shows that NT-pro-BNP levels, PT, and PaO2/FiO2 ratio are independently associated with in-hospital mortality in subjects with COVID-19 pneumonia. Further longitudinal studies are warranted to confirm the results of this study

    Reconstruction of the gravitational wave signal h(t)h(t) during the Virgo science runs and independent validation with a photon calibrator

    Full text link
    The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity. In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series h(t)h(t) from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the h(t)h(t) signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed h(t)h(t) signal and the associated uncertainties. The uncertainties of the h(t)h(t) time series are estimated to be 8% in amplitude. The uncertainty of the phase of h(t)h(t) is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 μ\mus at high frequency. A bias lower than 4 μs4\,\mathrm{\mu s} and depending on the sky direction of the GW is also present.Comment: 35 pages, 16 figures. Accepted by CQ

    The variable finesse locking technique

    Get PDF
    Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way

    Calibration and sensitivity of the Virgo detector during its second science run

    Full text link
    The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.Comment: 30 pages, 23 figures, 1 table. Published in Classical and Quantum Gravity (CQG), Corrigendum include
    • …
    corecore