211 research outputs found

    Development of an Additively Manufactured Capacitive Humidity Sensor for the International Space Station

    Get PDF
    The ability to measure humidity on the International Space Station and other long-duration spaceflight missions is a crucial part of the onboard systems. For example, the Environmental Control and Life Support System (ECLSS) needs to know the amount of humidity in the air to make decisions about whether it should spend power to run the dehumidifier systems to attempt to reclaim that water. Other issues can arise if the humidity reaches too high of levels and condensation builds up on electrical components. With that in mind, it is vital that the spacecraft keeps spare sensors on board or has the ability to manufacture new sensors on demand. An additively manufactured sensor would be additionally beneficial because it would save space onboard that would normally be taken up by spares, save money from costly resupply missions, and allow the sensor to be constantly updated with the most effective design. This Technical Memorandum outlines a development process carried out to design, manufacture, and test an additively manufactured humidity sensor

    Priprava, in vitro i in vivo evaluacija bioadhezivnih mikrosfera s algino-pektinom: ispitivanje utjecaja polimera pomoću multiple poredbene analize

    Get PDF
    Ionotropic gelation was used to entrap aceclofenac into algino-pectinate bioadhesive microspheres as a potential drug carrier for the oral delivery of this anti-inflammatory drug. Microspheres were investigated in vitro for possible sustained drug release and their use in vivo as a gastroprotective system for aceclofenac. Polymer concentration and polymer/drug ratio were analyzed for their influence on microsphere properties. The microspheres exhibited good bioadhesive property and showed high drug entrapment efficiency. Drug release profiles exhibited faster release of aceclofenac from alginate microspheres whereas algino-pectinate microspheres showed prolonged release. Dunett\u27s multiple comparison analyis suggested a significant difference in percent inhibition of paw edema when the optimized formulation was compared to pure drug. It was concluded that the algino-pectinate bioadhesive formulations exhibit promising properties of a sustained release form for aceclofenac and that they provide distinct tissue protection in the stomach.U radu je opisana priprava algino-pektinskih bioadhezivnih mikrosfera protuupalnog lijeka aceklofenaka metodom ionotropnog geliranja. In vitro je ispitivana mogućnost postupnog oslobađanja ljekovite tvari iz mikrosfera te mogućnost upotrebe mikrosfera kao gastroprotektivnog sustava za isporuku aceklofenaka in vivo. Ispitivan je utjecaj koncentracije polimera i omjera polimera i lijeka na svojstva mikrosfera. Mikrosfere su bile bioahezivne i sadržavale su veliki udio lijeka. Oslobađanje aceklofenaka iz alginatnih mikrosfera bilo je brže, a iz mikrosfera s algino-pektinom usporeno. Dunnetova multipla analiza ukazuje na značajnu razliku u postotku inhibicije edema šape kada se usporede optimizirana formulacija i čista ljekovita tvar. Može se zaključiti da su bioadhezivne mikrosfere s algino-pektinom povoljne za usporeno oslobađanje aceklofenaka te da pružaju umjerenu zaštitu sluznice želuca

    The ANTARES Optical Beacon System

    Get PDF
    ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented.Comment: 21 pages, 18 figures, submitted to Nucl. Instr. and Meth. Phys. Res.

    Background Light in Potential Sites for the ANTARES Undersea Neutrino Telescope

    Get PDF
    The ANTARES collaboration has performed a series of {\em in situ} measurements to study the background light for a planned undersea neutrino telescope. Such background can be caused by 40^{40}K decays or by biological activity. We report on measurements at two sites in the Mediterranean Sea at depths of 2400~m and 2700~m, respectively. Three photomultiplier tubes were used to measure single counting rates and coincidence rates for pairs of tubes at various distances. The background rate is seen to consist of three components: a constant rate due to 40^{40}K decays, a continuum rate that varies on a time scale of several hours simultaneously over distances up to at least 40~m, and random bursts a few seconds long that are only correlated in time over distances of the order of a meter. A trigger requiring coincidences between nearby photomultiplier tubes should reduce the trigger rate for a neutrino telescope to a manageable level with only a small loss in efficiency.Comment: 18 pages, 8 figures, accepted for publication in Astroparticle Physic

    Enteral versus parenteral early nutrition in ventilated adults with shock: a randomised, controlled, multicentre, open-label, parallel-group study (NUTRIREA-2)

    Get PDF
    BACKGROUND: Whether the route of early feeding affects outcomes of patients with severe critical illnesses is controversial. We hypothesised that outcomes were better with early first-line enteral nutrition than with early first-line parenteral nutrition. METHODS: In this randomised, controlled, multicentre, open-label, parallel-group study (NUTRIREA-2 trial) done at 44 French intensive-care units (ICUs), adults (18 years or older) receiving invasive mechanical ventilation and vasopressor support for shock were randomly assigned (1:1) to either parenteral nutrition or enteral nutrition, both targeting normocaloric goals (20-25 kcal/kg per day), within 24 h after intubation. Randomisation was stratified by centre using permutation blocks of variable sizes. Given that route of nutrition cannot be masked, blinding of the physicians and nurses was not feasible. Patients receiving parenteral nutrition could be switched to enteral nutrition after at least 72 h in the event of shock resolution (no vasopressor support for 24 consecutive hours and arterial lactate <2 mmol/L). The primary endpoint was mortality on day 28 after randomisation in the intention-to-treat-population. This study is registered with ClinicalTrials.gov, number NCT01802099. FINDINGS: After the second interim analysis, the independent Data Safety and Monitoring Board deemed that completing patient enrolment was unlikely to significantly change the results of the trial and recommended stopping patient recruitment. Between March 22, 2013, and June 30, 2015, 2410 patients were enrolled and randomly assigned; 1202 to the enteral group and 1208 to the parenteral group. By day 28, 443 (37%) of 1202 patients in the enteral group and 422 (35%) of 1208 patients in the parenteral group had died (absolute difference estimate 2·0%; [95% CI -1·9 to 5·8]; p=0·33). Cumulative incidence of patients with ICU-acquired infections did not differ between the enteral group (173 [14%]) and the parenteral group (194 [16%]; hazard ratio [HR] 0·89 [95% CI 0·72-1·09]; p=0·25). Compared with the parenteral group, the enteral group had higher cumulative incidences of patients with vomiting (406 [34%] vs 246 [20%]; HR 1·89 [1·62-2·20]; p<0·0001), diarrhoea (432 [36%] vs 393 [33%]; 1·20 [1·05-1·37]; p=0·009), bowel ischaemia (19 [2%] vs five [<1%]; 3·84 [1·43-10·3]; p=0·007), and acute colonic pseudo-obstruction (11 [1%] vs three [<1%]; 3·7 [1·03-13·2; p=0·04). INTERPRETATION: In critically ill adults with shock, early isocaloric enteral nutrition did not reduce mortality or the risk of secondary infections but was associated with a greater risk of digestive complications compared with early isocaloric parenteral nutrition. FUNDING: La Roche-sur-Yon Departmental Hospital and French Ministry of Health

    New discoveries in the transmission biology of sleeping sickness parasites: applying the basics

    Get PDF
    The sleeping sickness parasite, Trypanosoma brucei, must differentiate in response to the changing environments that it encounters during its complex life cycle. One developmental form, the bloodstream stumpy stage, plays an important role in infection dynamics and transmission of the parasite. Recent advances have shed light on the molecular mechanisms by which these stumpy forms differentiate as they are transmitted from the mammalian host to the insect vector of sleeping sickness, tsetse flies. These molecular advances now provide improved experimental tools for the study of stumpy formation and function within the mammalian bloodstream. They also offer new routes to therapy via high-throughput screens for agents that accelerate parasite development. Here, we shall discuss the recent advances that have been made and the prospects for future research now available
    corecore