104 research outputs found

    MODERN METHODS AND POSSIBILITIES FOR DYNAMIC DIAGNOSTICS OF PULMONARY DISEASES

    Get PDF
    No abstrac

    Ectopic pregnancy after assisted reproductive technology: a retrospective study

    Get PDF
    In this study from 2006 to 2010,1628 IVF-ET cycles were performed in our unit. Long protocol with GnRH agonist plus recombinant FSH, short protocol with GnRH antagonist, short protocol with microdoses of GnRH agonist (flare up), natural modified cycle with GnRH antagonist and hCG were applied. The serum level of the P-hCG was measured 12 days after embryotransfer (ET). When positive, the P-hCG level was determined every 4 days until the ultrasound examination 22 days after the ET. From 1628 IVF - ET cycles, we had 10 tubal pregnancies (0,61%) and one heterotopic pregnancy (HP). Salpingectomy was performed in all patients, 7 had laparoscopy, and 3 underwent emergent laparotomy due to hemorrhagic shock. Regarding the HP patient, an ultrasound scan confirmed a viable intrauterine 8-weeks gestation and an ectopic pregnancy (EP) in the left tube with fetal heartbeat corresponding to gestational age of 7-8 weeks. Laparoscopy with left salpingectomy was performed the following day. The intrauterine pregnancy proceeded uneventfully. The patient delivered by elective Cesarean section at 39 weeks of gestation due to breech presentation. Patients undergoing IVF-ET must be informed of the risk of EP and the possibility of HP should not be ignored

    LOCALIZATION OF PULMONARY THROMBOEMBOLISM - AN IMPORTANT PROGNOSTIC FACTOR

    Get PDF
    The prognosis of pulmonary thromboembolism is a serious challenge for the clinicians. A total of 967 patients with pulmonary thromboembolism, 511 males and 456 females at a mean age of 60,1 ±13,7 years were analyzed. A special protocol consisting of 52 parameters was used to define their prognostic value. A non-invasive diagnostic algorithm based on symptoms, ECG, pulmonary roentgenography, perfusion scintigraphy, spiral scan, pulmoangiography, or on autopsy was applied. A prognostic index was elaborated by means of multifactorial analysis of the parameters of prognostic significance concerning the risk of lethal outcome. The localization of the pulmonary thromboembolism as determined by using spiral C T can effectively be used for patients' risk stratification

    Organic solar cells as high-speed data detectors for visible light communication

    Get PDF
    Funding: Engineering and Physical Sciences Research Council (EPSRC) (EP/I00243X, EP/K00042X/1, EP/K008757/1).We show that solar cells, widely used in portable devices for power generation, can simultaneously extract a high-speed data signal in an optical wireless communication link. This Letter reports, to the best of our knowledge, the first use of an organic solar cell as an energy-harvesting receiver for visible light communications (VLCs). While generating maximum power in the cell, the communication link can deliver a data rate of 34.2 Mbps with a bit error rate of 4.08 x 10(-4) using an implementation of orthogonal frequency-division multiplexing. This approach could lead to printed optical data receivers in future eco-friendly VLC systems. Simultaneous functions of data communication and energy harvesting have great implications for the connectivity of future smart devices, many of which could become self-powered units as part of the "Internet of Things."PostprintPeer reviewe

    Functional and structural leaf plasticity determine photosynthetic performances during drought stress and recovery in two platanus orientalis populations from contrasting habitats.

    Get PDF
    In the context of climatic change, more severe and long-lasting droughts will modify the fitness of plants, with potentially worse consequences on the relict trees. We have investigated the leaf phenotypic (anatomical, physiological and biochemical) plasticity in well-watered, drought- stressed and re-watered plants of two populations of Platanus orientalis, an endangered species in the west of the Mediterranean area. The two populations originated in contrasting climate (drier and warmer, Italy (IT) population; more humid and colder, Bulgaria (BG) population). The IT control plants had thicker leaves, enabling them to maintain higher leaf water content in the dry environment, and more spongy parenchyma, which could improve water conductivity of these plants and may result in easier CO2 diffusion than in BG plants. Control BG plants were also characterized by higher photorespiration and leaf antioxidants compared to IT plants. BG plants responded to drought with greater leaf thickness shrinkage. Drought also caused substantial reduction in photosynthetic parameters of both IT and BG plants. After re-watering, photosynthesis did not fully recover in either of the two populations. However, IT leaves became thicker, while photorespiration in BG plants further increased, perhaps indicating sustained activation of defensive mechanisms. Overall, our hypothesis, that plants with a fragmented habitat (i.e., the IT population) lose phenotypic plasticity but acquire traits allowing better resistance to the climate where they became adapted, remains confirmed

    Visible light communication using InGaN optical sources with AlInGaP nanomembrane down-converters

    Get PDF
    We report free space visible light communication using InGaN sources, namely micro-LEDs and a laser diode, down-converted by a redemitting AlInGaP multi-quantum-well nanomembrane. In the case of microLEDs, the AlInGaP nanomembrane is capillary-bonded between the sapphire window of a micro-LED array and a hemispherical sapphire lens to provide an integrated optical source. The sapphire lens improves the extraction efficiency of the color-converted light. For the case of the downconverted laser diode, one side of the nanomembrane is bonded to a sapphire lens and the other side optionally onto a dielectric mirror; this nanomembrane-lens structure is remotely excited by the laser diode. Data transmission up to 870 Mb/s using pulse amplitude modulation (PAM) with fractionally spaced decision feedback equalizer is demonstrated for the micro-LED-integrated nanomembrane. A data rate of 1.2 Gb/s is achieved using orthogonal frequency division multiplexing (ODFM) with the laser diode pumped sample

    Visible Light Communication Using a Blue GaN μLED and Fluorescent Polymer Color Converter

    Get PDF
    This letter presents a novel technique to achieve high-speed visible light communication (VLC) using white light generated by a blue GaN mu LED and a yellow fluorescent copolymer. We generated white light suitable for room illumination by optimizing the ratio between the blue electroluminescence of the mu LED and yellow photoluminescence of the copolymer color converter. Taking advantage of the components' high bandwidth, we demonstrated 1.68 Gb/s at a distance of 3 cm (at 240 lx illumination). To the best of our knowledge, this is the fastest white light VLC results using a single blue LED/color converter combination.PostprintPeer reviewe

    Preparation and characterization of stable aqueous suspensions of up-converting Er3+/Yb3+-doped LiNbO3 nanocrystals

    Get PDF
    The preparation of LiNbO3:Er3+/Yb3+ nanocrystals and their up-conversion properties have been studied. It is demonstrated that polyethyleneimine- (PEI) assisted dispersion procedures allow obtaining stable aqueous LiNbO3:Er3+/Yb3+ powder suspensions, with average size particles well below the micron range (100–200 nm) and the isoelectric point of the suspension reaching values well above pH 7. After excitation of Yb3+ ions at a wavelength of 980 nm, the suspensions exhibit efficient, and stable, IR-to-visible (green and red) up-conversion properties, easily observed by the naked eye, very similar to those of the starting crystalline bulk material

    Multicentric Atrial Strain COmparison between Two Different Modalities: MASCOT HIT Study

    Get PDF
    Two methods are currently available for left atrial (LA) strain measurement by speckle tracking echocardiography, with two different reference timings for starting the analysis: QRS (QRS-LASr) and P wave (P-LASr). The aim of MASCOT HIT study was to define which of the two was more reproducible, more feasible, and less time consuming. In 26 expert centers, LA strain was analyzed by two different echocardiographers (young vs senior) in a blinded fashion. The study population included: healthy subjects, patients with arterial hypertension or aortic stenosis (LA pressure overload, group 2) and patients with mitral regurgitation or heart failure (LA volume–pressure overload, group 3). Difference between the inter-correlation coefficient (ICC) by the two echocardiographers using the two techniques, feasibility and analysis time of both methods were analyzed. A total of 938 subjects were included: 309 controls, 333 patients in group 2, and 296 patients in group 3. The ICC was comparable between QRS-LASr (0.93) and P-LASr (0.90). The young echocardiographers calculated QRS-LASr in 90% of cases, the expert ones in 95%. The feasibility of P-LASr was 85% by young echocardiographers and 88% by senior ones. QRS-LASr young median time was 110 s (interquartile range, IR, 78-149) vs senior 110 s (IR 78-155); for P-LASr, 120 s (IR 80-165) and 120 s (IR 90-161), respectively. LA strain was feasible in the majority of patients with similar reproducibility for both methods. QRS complex guaranteed a slightly higher feasibility and a lower time wasting compared to the use of P wave as the reference
    corecore