1,070 research outputs found
Analgesic prescribing trends in a national sample of older veterans with osteoarthritis: 2012-2017
Few investigations examine patterns of opioid and nonopioid analgesic prescribing and concurrent pain intensity ratings before and after institution of safer prescribing programs such as the October 2013 Veterans Health Administration system-wide Opioid Safety Initiative (OSI) implementation. We conducted a quasi-experimental pre–post observational study of all older U.S. veterans (≥50 years old) with osteoarthritis of the knee or hip. All associated outpatient analgesic prescriptions and outpatient pain intensity ratings from January 1, 2012 to December 31, 2016, were analyzed with segmented regression of interrupted time series. Standardized monthly rates for each analgesic class (total, opioid, nonsteroidal anti-inflammatory drug, acetaminophen, and other study analgesics) were analyzed with segmented negative binomial regression models with overall slope, step, and slope change. Similarly, segmented linear regression was used to analyze pain intensity ratings and percentage of those reporting pain. All models were additionally adjusted for age, sex, and race. Before OSI implementation, total analgesic prescriptions showed a steady rise, abruptly decreasing to a flat trajectory after OSI implementation. This trend was primarily due to a decrease in opioid prescribing after OSI. Total prescribing after OSI implementation was partially compensated by continuing increased prescribing of other study analgesics as well as a significant rise in acetaminophen prescriptions (post-OSI). No changes in nonsteroidal anti-inflammatory drug prescribing were seen. A small rise in the percentage of those reporting pain but not mean pain intensity ratings continued over the study period with no changes associated with OSI. Changes in analgesic prescribing trends were not paralleled by changes in reported pain intensity for older veterans with osteoarthritis
Shape parametrization for liquid-drop studies
We present a new method for defining axially symmetric shapes which is particularly appropriate for describing elongated and multineck configurations. This shape parametrization is used to describe the static properties of incompressible, charged liquid drops. In particular, we calculate the properties of binary-fission saddle points and compare these with results using other methods. We also present the geometrical properties and normal mode analyses of the two-and three-necked saddle-point families
Antibiotic de-escalation experience in the setting of emergency department: A retrospective, observational study
Background: Antimicrobial de-escalation (ADE) is a part of antimicrobial stewardship strategies aiming to minimize unnecessary or inappropriate antibiotic exposure to decrease the rate of antimicrobial resistance. Information regarding the effectiveness and safety of ADE in the setting of emergency medicine wards (EMW) is lacking. Methods: Adult patients admitted to EMW and receiving empiric antimicrobial treatment were retrospectively studied. The primary outcome was the rate and timing of ADE. Secondary outcomes included factors associated with early ADE, length of stay, and in-hospital mortality. Results: A total of 336 patients were studied. An initial regimen combining two agents was prescribed in 54.8%. Ureidopenicillins and carbapenems were the most frequently empiric treatment prescribed (25.1% and 13.6%). The rate of the appropriateness of prescribing was 58.3%. De-escalation was performed in 111 (33%) patients. Patients received a successful de-escalation on day 2 (21%), 3 (23%), and 5 (56%). The overall in-hospital mortality was 21%, and it was significantly lower among the de-escalation group than the continuation group (16% vs 25% p = 0.003). In multivariate analysis, de-escalation strategies as well as appropriate empiric and targeted therapy were associated with reduced mortality. Conclusions: ADE appears safe and effective in the setting of EMWs despite that further research is warranted to confirm these findings
Light-particle emission from the fissioning nuclei 126Ba, 188Pt and (266,272,278)/110: theoretical predictions and experimental results
We present a comparison of our model treating fission dynamics in conjunction
with light-particle (n, p, alpha) evaporation with the available experimental
data for the nuclei 126Ba, 188Pt and three isotopes of the element Z=110. The
dynamics of the symmetric fission process is described through the solution of
a classical Langevin equation for a single collective variable characterizing
the nuclear deformation along the fission path. A microscopic approach is used
to evaluate the emission rates for pre-fission light particles.
Entrance-channel effects are taken into account by generating an initial spin
distribution of the compound nucleus formed by the fusion of two deformed
nuclei with different relative orientations
The STAR Time Projection Chamber: A Unique Tool for Studying High Multiplicity Events at RHIC
The STAR Time Projection Chamber (TPC) is used to record collisions at the
Relativistic Heavy Ion Collider (RHIC). The TPC is the central element in a
suite of detectors that surrounds the interaction vertex. The TPC provides
complete coverage around the beam-line, and provides complete tracking for
charged particles within +- 1.8 units of pseudo-rapidity of the center-of-mass
frame. Charged particles with momenta greater than 100 MeV/c are recorded.
Multiplicities in excess of 3,000 tracks per event are routinely reconstructed
in the software. The TPC measures 4 m in diameter by 4.2 m long, making it the
largest TPC in the world.Comment: 28 pages, 11 figure
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will
search for neutrinoless double beta decay of Te. With 741 kg of TeO
crystals and an excellent energy resolution of 5 keV (0.2%) at the region of
interest, CUORE will be one of the most competitive neutrinoless double beta
decay experiments on the horizon. With five years of live time, CUORE projected
neutrinoless double beta decay half-life sensitivity is y
at ( y at the 90% confidence level), which
corresponds to an upper limit on the effective Majorana mass in the range
40--100 meV (50--130 meV). Further background rejection with auxiliary light
detector can significantly improve the search sensitivity and competitiveness
of bolometric detectors to fully explore the inverted neutrino mass hierarchy
with Te and possibly other double beta decay candidate nuclei.Comment: Submitted to the Proceedings of TAUP 2013 Conferenc
Validation of techniques to mitigate copper surface contamination in CUORE
In this article we describe the background challenges for the CUORE
experiment posed by surface contamination of inert detector materials such as
copper, and present three techniques explored to mitigate these backgrounds.
Using data from a dedicated test apparatus constructed to validate and compare
these techniques we demonstrate that copper surface contamination levels better
than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels
are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit
on the number of background counts in the region of interest is 0.02-0.03
counts/keV/kg/y depending on the adopted mitigation technique.Comment: 10 pages, 6 figures, 6 table
CUORE-0 results and prospects for the CUORE experiment
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV
(0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory
for Rare Events) experiment aims at searching for neutrinoless double beta
decay of 130Te with unprecedented sensitivity. Expected to start data taking in
2015, CUORE is currently in an advanced construction phase at LNGS. CUORE
projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1
sigma (9.5E25 y at the 90% confidence level), in five years of live time,
corresponding to an upper limit on the effective Majorana mass in the range
40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric
detectors could improve CUORE sensitivity and competitiveness of bolometric
detectors towards a full analysis of the inverted neutrino mass hierarchy.
CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE
experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g
each, arranged in a 13 floor structure) constructed strictly following CUORE
recipes both for materials and assembly procedures. An experiment its own,
CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta
decay half-life of 130Te around 3E24 y in one year of live time. We present an
update of the data, corresponding to an exposure of 18.1 kg y. An analysis of
the background indicates that the CUORE performance goal is satisfied while the
sensitivity goal is within reach.Comment: 10 pages, 3 figures, to appear in the proceedings of NEUTRINO 2014,
26th International Conference on Neutrino Physics and Astrophysics, 2-7 June
2014, held at Boston, Massachusetts, US
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.Comment: 22 pages, 15 figures, submitted to EPJ
- …